PubMed Health⌕ Search

Biomedical subjects

Thomas M Link

Publications and source records attributed to Thomas M Link.

At least 19 recordsLinked to original sources

Cartilage imaging: motivation, techniques, current and future significance.

Cartilage repair techniques and pharmacological therapies are currently areas of major clinical interest and research, in particular to prevent and treat osteoarthritis. MR imaging-based techniques to visualize cartilage are prerequisites to guide and monitor these therapies. In this review article, standard MR imaging sequences are described, including proton density-weighted fast spin echo, spoiled gradient echo and dual echo steady state sequences. In addition, new sequences that have been developed and are currently being investigated are presented, including driven equilibrium Fourier transform and steady-state free precession-based imaging. Using high-field MR imaging at 3.0-T, visualization of cartilage and the related pathology has been improved. Volumetric quantitative cartilage MR imaging was developed as a tool to monitor the progression of osteoarthritis and to evaluate new pharmacological cartilage protective therapies. The most exciting developments, however, are in the field of cartilage matrix assessment with quantitative dGEMRIC, T2 and T1rho mapping techniques. These techniques aim at detecting cartilage damage at a stage when changes are potentially still reversible, before cartilage tissue is lost. There is currently substantial interest in these techniques from rheumatologists and orthopedists; radiologists therefore need to keep up with these developments.

Cartilage Diseases↗

MR imaging of the ankle at 3 Tesla and 1.5 Tesla: protocol optimization and application to cartilage, ligament and tendon pathology in cadaver specimens.

The objective of this study was to optimize ankle joint MR imaging in volunteers at 1.5 Tesla (T) and 3.0 T, and to compare these optimized sequences concerning image quality and performance in assessing cartilage, ligament and tendon pathology in fresh human cadaver specimens. Initially our clinical ankle protocol consisting of T1-weighted (-w), fat-saturated (fs) T2-w, and short tau inversion-recovery fast spinecho (FSE) sequences was optimized at 1.5 T and 3.0 T by two radiologists. For dedicated cartilage imaging, fs-intermediate (IM)-w FSE, fs spoiled gradient echo, and balanced free-precession steady-state sequences were optimized. Using the optimized sequences, thirteen cadaver ankle joints were imaged. Four radiologists independently assessed these images concerning image quality and pathology. All radiologists consistently rated image quality higher at 3.0 T (all sequences p<0.05). For detecting cartilage pathology, diagnostic performance was significantly higher at 3.0 T (ROC-values up to 0.93 vs. 0.77; p<0.05); the fs-IM FSE sequence showed highest values among the different sequences. Average sensitivity for detecting tendon pathology was 63% at 3.0 T vs. 41% at 1.5 T and was significantly higher at 3.0 T for 2 out of 4 radiologists (p<0.05). Compared to 1.5 T, imaging of the ankle joint at 3.0 T significantly improved image quality and diagnostic performance in assessing cartilage pathology.

Aged↗

MR imaging of therapy-induced changes of bone marrow.

MR imaging of bone marrow infiltration by hematologic malignancies provides non-invasive assays of bone marrow cellularity and vascularity to supplement the information provided by bone marrow biopsies. This article will review the MR imaging findings of bone marrow infiltration by hematologic malignancies with special focus on treatment effects. MR imaging findings of the bone marrow after radiation therapy and chemotherapy will be described. In addition, changes in bone marrow microcirculation and metabolism after anti-angiogenesis treatment will be reviewed. Finally, new specific imaging techniques for the depiction of regulatory events that control blood vessel growth and cell proliferation will be discussed. Future developments are directed to yield comprehensive information about bone marrow structure, function and microenvironment.

Anti-Inflammatory Agents↗

A feasibility study of in vivo T1rho imaging of the intervertebral disc.

PURPOSE: Recent studies have proposed that magnetic resonance (MR) T1rho relaxation time is associated with loss of macromolecules. The depletion of macromolecules in the matrix of the intervertebral disc may be an initiating factor in degenerative disc disease. The purpose of this study was to test the feasibility of quantifying T1rho relaxation time in phantoms and intervertebral discs of healthy volunteers using in vivo MR imaging at 3 T. MATERIALS AND METHODS: A multislice T1rho spiral sequence was used to quantify T1rho relaxation time in phantoms with different agarose concentrations and in the intervertebral discs of 11 healthy volunteers (mean age=31.3 years; age range=23-60 years; gender: 5 females, 6 males). RESULTS: The phantom studies demonstrated the feasibility of using spiral imaging at 3 T. The in vivo results indicate that the median T1rho value of the nucleus (116.6+/-21.4 ms) is significantly greater (P<0.05) than that of the annulus (84.1+/-11.7 ms). The correlations between the age of the volunteers and T1rho relaxation time in the nucleus (r2=-0.82; P=0.0001) and the annulus (r2=-0.37; P=0.04) were significant. A trend of decreasing T1rho values from L3-4 to L4-5 to L5-S1 was evident. CONCLUSION: The results of this study suggest that in vivo T1rho quantification is feasible and may potentially be a clinical tool in identifying early degenerative changes in the intervertebral disc.

Adult↗

Characterization of trabecular bone structure from high-resolution magnetic resonance images using fuzzy logic.

The purpose of this work was to apply fuzzy logic image processing techniques to characterize the trabecular bone structure with high-resolution magnetic resonance images. Fifteen ex vivo high-resolution magnetic resonance images of specimens of human radii at 1.5 T and 12 in vivo high-resolution magnetic resonance images of the calcanei of peri- and postmenopausal women at 3 T were obtained. Soft segmentation using fuzzy clustering was applied to MR data to obtain fuzzy bone volume fraction maps, which were then analyzed with three-dimensional (3D) fuzzy geometrical parameters and measures of fuzziness. Geometrical parameters included fuzzy perimeter and fuzzy compactness, while measures of fuzziness included linear index of fuzziness, quadratic index of fuzziness, logarithmic fuzzy entropy, and exponential fuzzy entropy. Fuzzy parameters were validated at 1.5 T with 3D structural parameters computed from microcomputed tomography images, which allow the observation of true trabecular bone structure and with apparent MR structural indexes at 1.5 T and 3 T. The validation was statistically performed with the Pearson correlation coefficient as well as with the Bland-Altman method. Bone volume fraction correlation values (r) were up to .99 (P<.001) with good agreements based on Bland-Altman analysis showing that fuzzy clustering is a valid technique to quantify this parameter. Measures of fuzziness also showed consistent correlations to trabecular number parameters (r>.85; P<.001) and good agreements based on Bland-Altman analysis, suggesting that the level of fuzziness in high-resolution magnetic resonance images could be related to the trabecular bone structure.

Aged↗

Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.

PURPOSE: To investigate in vitro the calcaneal trabecular bone structure in elderly human donors with high spatial resolution magnetic resonance (MR) imaging at 3.0 T and 1.5 T, to quantitatively compare MR measures of bone microarchitecture with those from micro-computed tomography (CT), and to compare the performance of 3.0-T MR imaging with that of 1.5-T MR imaging in differentiating donors with spinal fractures from those without spinal fractures. MATERIALS AND METHODS: The study was performed in line with institutional and legislative requirements; all donors had dedicated their body for educational and research purposes prior to death. Sagittal MR images of 49 human calcaneus cadaveric specimens were obtained (mean age of donors, 79.5 years +/- 11 [standard deviation]; 26 male donors, 23 female donors). After the spatial coregistering of images acquired at 3.0-T and 1.5-T MR imaging, the signal-to-noise-ratios and structural parameters obtained at each magnetic field strength were compared in corresponding sections. Micro-CT was performed on calcaneus cores obtained from corresponding regions in 40 cadaveric specimens. Vertebral deformities of the thoracic and lumbar spine were radiographically classified by using the spinal fracture index. Diagnostic performance of the structural parameters in differentiating donors with vertebral fractures from those without was assessed by using receiver operator characteristic (ROC) analysis, including area under the ROC curve (A(z)). RESULTS: Correlations between structural parameters at 3.0-T MR imaging and those at micro-CT were significantly higher (P < .05) than correlations between structural parameters at 1.5-T MR imaging and those at micro-CT (trabecular thickness, r = 0.76 at 3.0 T vs r = 0.57 at 1.5 T). Trabecular dimensions were amplified at 3.0 T because of increasing susceptibility artifacts. Also, higher ROC values were found for structural parameters at 3.0 T than at 1.5 T, but differences were not significant (trabecular thickness, A(z) = 0.75 at 3.0 T vs A(z) = 0.66 at 1.5 T, P > .05). CONCLUSION: MR imaging at 3.0 T provided a better measure of the trabecular bone structure than did MR imaging at 1.5 T. There was a trend for better differentiation of donors with from those without osteoporotic vertebral fractures at 3.0 T than at 1.5 T.

Aged↗

Quantitative MRI of cartilage and bone: degenerative changes in osteoarthritis.

Magnetic resonance imaging (MRI) and quantitative image analysis technology has recently started to generate a great wealth of quantitative information on articular cartilage and bone physiology, pathophysiology and degenerative changes in osteoarthritis. This paper reviews semiquantitative scoring of changes of articular tissues (e.g. WORMS = whole-organ MRI scoring or KOSS = knee osteoarthritis scoring system), quantification of cartilage morphology (e.g. volume and thickness), quantitative measurements of cartilage composition (e.g. T2, T1rho, T1Gd = dGEMRIC index) and quantitative measurement of bone structure (e.g. app. BV/TV, app. TbTh, app. Tb.N, app. Tb.Sp) in osteoarthritis. For each of these fields we describe the hardware and MRI sequences available, the image analysis systems and techniques used to derive semiquantitative and quantitative parameters, the technical accuracy and precision of the measurements reported to date and current results from cross-sectional and longitudinal studies in osteoarthritis. Moreover, the paper summarizes studies that have compared MRI-based measurements with radiography and discusses future perspectives of quantitative MRI in osteoarthritis. In summary, the above methodologies show great promise for elucidating the pathophysiology of various tissues and identifying risk factors of osteoarthritis, for developing structure modifying drugs (DMOADs) and for combating osteoarthritis with new and better therapy.

Animals↗

Comparison of different radiography systems in an experimental study for detection of forearm fractures and evaluation of the Müller-AO and Frykman classification for distal radius fractures.

OBJECTIVES: We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation. MATERIALS AND METHODS: A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis. RESULTS: The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications. CONCLUSIONS: The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.

Area Under Curve↗

Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy.

PURPOSE: To compare the precision and accuracy of 3.0-T and 1.5-T magnetic resonance (MR) imaging in the quantification of cartilage volume by using direct volumetric measurements as a reference standard. MATERIALS AND METHODS: The local animal experimentation committee did not require its approval for this study. Porcine knees were obtained from an abattoir. These specimens were used to optimize imaging parameters regarding effective signal-to-noise ratio (SNRE) and contrast-to-noise ratio (CNRE) for a fat-saturated spoiled gradient-recalled acquisition in the steady state (SPGR) sequence, a water excitation SPGR sequence, and a fast spin-echo sequence at 3.0 T and a fat-saturated SPGR sequence at 1.5 T. By using the optimized sequences, 18 specimens were imaged in less than 6 minutes per sequence. A fivefold repetition of measurements of four specimens was performed for precision analysis. Cartilage was segmented by using semiautomatic software to calculate the volume. After imaging, the cartilage was scraped off and the volume was measured directly by using a saline-displacement method to calculate accuracy. Precision and accuracy errors were calculated as the root-mean-squares of the single errors per specimen. RESULTS: SNRE and CNRE values, respectively, were highest for the water excitation sequence at 3.0 T (1.81 sec(-1/2) and 1.27 sec(-1/2)), followed by the fat-saturated SPGR sequence (1.52 sec(-1/2) and 1.07 sec(-1/2)). The fast spin-echo sequence and the fat-saturated SPGR sequence at 1.5 T had lower SNR(E) (1.27 sec(-1/2) and 0.59 sec(-1/2), respectively). Accuracy error for MR-based volume calculation at the femur was 5.0%, 3.0%, 21%, and 16% for the water excitation, fat-saturated SPGR, and fast spin-echo sequences at 3.0 T and the fat-saturated SPGR sequence at 1.5 T, respectively. CONCLUSION: MR imaging at 3.0 T was shown in our study to better quantify cartilage volume. SNRE and CNRE were substantially improved, resulting in significantly higher accuracy in determining cartilage volume.

Animals↗

Comparison of 16-slice MSCT and MRI in the assessment of squamous cell carcinoma of the oral cavity.

The goal of this retrospective study was to assess the accuracy of 16-slice multislice CT (MSCT) and MRI in staging of patients with primary squamous cell carcinoma (SCC) of the oral cavity. Fifty-two patients with histologically proven primary SCC were examined with contrast enhanced MSCT and MRI at 1.5 T with a combined head and surface neck coil. Image modalities were evaluated in a blinded fashion by two radiologists and an oral-maxillofacial surgeon in consensus concerning tumour depiction, local tumour infiltration and cervical lymph node metastases. Results of the radiological assessment were correlated with the intraoperative and histopathological findings in all patients. 36 of 52 primary tumours (69.2%) were depicted by MSCT while 44 were localized by MRI (84.6%). Regarding muscle infiltration MRI versus MSCT had a sensitivity of 81.8% versus 72.7%, but a low specificity and an accuracy of 63.4% versus 61% and 67.3% versus 63.5%, respectively, were found. There was a trend towards a better detection of bony infiltration by MRI than MSCT with a sensitivity of 100% versus 71.4%, a specificity of 93.3% versus 95.5% and an accuracy 94.2% versus 92.3%, respectively. Detection of cervical lymph node involvement was similar for MRI and MSCT with a sensitivity of 84.2% and 78.9%, a specificity of 63.6% and 75.7% and an accuracy of 71.1% and 76.9%, respectively. For N-staging both methods failed to detect small metastasis. For T-staging MRI was superior to MSCT, because there was a tendency to underestimate the tumour size by MSCT more often (19.4% versus 6.8% by MRI). Therefore, pre-operative MRI is recommended as the basic imaging modality of choice for treatment planning of oral SCC. MSCT is a valid alternative imaging method especially in cases with low patient compliance.

Aged↗

MR imaging findings in the follow-up of patients with different stages of knee osteoarthritis and the correlation with clinical symptoms.

OBJECTIVE: To assess the rate of cartilage loss, the change in bone marrow edema pattern and internal joint derangement at 1.5-T MRI in patients with knee osteoarthritis and to correlate these findings with the clinical Western Ontario and McMaster University Osteoarthitis (WOMAC) score. METHODS: Forty subjects (mean age 57.7+/-15 years; 16 females and 24 males) were recruited: 6 healthy volunteers (OA0), 17 patients with mild osteoarthritis (OA1) and 17 with severe osteoarthritis (OA2) based on the Kellgren-Lawrence scale. MR scans, radiographs and WOMAC scores were obtained at baseline, first follow-up (1.4+/-0.67 years; n=40) and second follow-up (2.4+/-0.4 years; n=26). Cartilage morphology, bone marrow edema (BME), meniscal and ligamentous pathology were assessed on MR images and quantified by two radiologists in consensus. RESULTS: Full-thickness cartilage lesions were observed in 12/17 OA2 at baseline, in 13/17 at the first follow-up and in 7/10 at the second follow-up. Cartilage loss was found in eight patients at the first follow-up and five at the second follow-up. BME was observed in 23/40 patients at baseline, in 22/40 at the first follow-up and in 12/26 at the second follow-up. Changes in BME were visualized in 19/22 and 4/13 patients at the first and second follow-up, respectively. Changes in WOMAC scores over time did not correlate significantly with the amount of cartilage loss and the change in BME (P>0.05). CONCLUSION: MRI is well suited to monitor the progression of OA in the longitudinal follow-up since it shows cartilage defects, BME and internal joint derangement, pathologies that are not visualized by radiographs. The lack of significant correlation between MRI findings and clinical findings is not unexpected, has been previously described and may in part be due to the fact that patients get more accustomed to their pain as the knee progressively degenerates.

Adult↗

Normal and pathological MR findings in osteochondral autografts with longitudinal follow-up.

The purpose of this study was to analyze normal and pathological MR findings in osteochondral autograft transfer systems (OATS) of the knee and ankle in the longitudinal follow-up and in relation to the clinical findings. MR imaging was performed in 55 patients (21 females: 34 males; mean age 34.5+/-12.1 years) after OATS procedures in the knee (n=45) and ankle (n=10). MR sequences were obtained with and without intravenous Gd-DTPA administration within the first year post-operatively, in 30 patients within the second and in 13 patients in the third year. One hundred and five OATS cylinders were implanted. MR findings consistent with osteonecroses were detected in eight cylinders (n=6 in the knee and n=2 in the ankle) in six patients; four out of eight were demonstrated during the first year and four/eight in the second year. Edema around and/or in the cylinders was found in 28/55 of the patients within the first year, five/30 in the second year and in two/13 in the third year. No substantial changes in the cartilage signal intensity or the cartilage-cartilage interface were demonstrated in the longitudinal follow-up within the first three years. Clinical and MR findings were not consistently associated in particular in the patients with osteochondral autograft necroses.

Adult↗

Radiologic assessment of osteoporotic vertebral fractures: diagnostic and prognostic implications.

As populations age osteoporosis becomes an increasingly important public health issue. Among osteoporotic fractures vertebral fractures are of particular relevance: they are the most common fractures, frequently are asymptomatic but have an important influence on prognosis and morbidity in the osteoporotic patient. Previous studies have suggested that these fractures are frequently not diagnosed and that radiologists miss a high percentage of osteoporotic, vertebral fractures present on lateral chest radiographs. The aims of this review are (1) to emphasize the important role that radiologists play in the accurate and clear reporting of vertebral fractures, (2) to provide guidance in assessing these fractures in radiographs, MRI and computed tomography imaging of the vertebral spine and (3) to sensitize the radiologist in diagnosing fractures in chest radiographs.

Aged↗

In vivo 3T spiral imaging based multi-slice T(1rho) mapping of knee cartilage in osteoarthritis.

T(1rho) describes the spin-lattice relaxation in the rotating frame and has been proposed for detecting damage to the cartilage collagen-proteoglycan matrix in osteoarthritis. In this study, a multi-slice T(1rho) imaging method for knee cartilage was developed using spin-lock techniques and a spiral imaging sequence. The adverse effect of T(1) regrowth during the multi-slice acquisition was eliminated by RF cycling. Agarose phantoms with different concentrations, 10 healthy volunteers, and 9 osteoarthritis patients were scanned at 3T. T(1rho) values decreased as agarose concentration increased. T(1rho) values obtained with imaging methods were compared with those obtained with spectroscopic methods. T(1rho) values obtained during multi-slice acquisition were validated with those obtained in a single slice acquisition. Reproducibility was assessed using the average coefficient of variation of median T(1rho), which was 0.68% in phantoms and 4.8% in healthy volunteers. There was a significant difference (P = 0.002) in the average T(1rho) within patellar and femoral cartilage between controls (45.04 +/- 2.59 ms) and osteoarthritis patients (53.06 +/- 4.60 ms). A significant correlation was found between T(1rho) and T(2); however, the difference of T(2) was not significant between controls and osteoarthritis patients. The results suggest that T(1rho) relaxation times may be a promising clinical tool for osteoarthritis detection and treatment monitoring.

Adolescent↗

Computer-aided quantification of focal cartilage lesions using MRI: accuracy and initial arthroscopic comparison.

OBJECTIVE: The purpose of the study was to validate a Gradient Peak Method (GPM) by evaluating its accuracy and consistency at different magnetic field strengths. The GPM using magnetic resonance imaging (MRI) was previously proposed to quantitatively assess the morphology of focal cartilage lesions, and its feasibility was demonstrated. METHODS: GPM quantifies the morphologic properties of cartilage lesions based on their three-dimensional geometry. Twenty-two conical and cylindrical lesions were surgically created on fresh porcine knees, and the results obtained by GPM were compared with manually measured lesion dimensions. Another 15 focal lesions of various shapes were created and scanned, and the quantification results were compared at 1.5 Tesla and 3 Tesla. Additionally, cartilage lesions in three patients were scanned, quantified by GPM, and compared with arthroscopic visualization and measurements. RESULTS: The average absolute errors of GPM (depth: < or =0.4mm; diameter: < or =1.4mm) were within twice the in-plane resolution in depth estimates and within the slice thickness in diameter estimates. Analysis also suggested that the quantifications of GPM using 1.5 Tesla and 3 Tesla data were not statistically different. Moreover, the GPM results were shown to be consistent with the lesion measurements obtained arthroscopically. CONCLUSIONS: The GPM using MRI provides estimates of lesion thickness, depth, diameter, and area. With this validation, the method can be potentially used as an auxiliary tool to help radiologists and physicians assess cartilage lesions quantitatively and monitor disease progression.

Animals↗

Migration of iron oxide-labeled human hematopoietic progenitor cells in a mouse model: in vivo monitoring with 1.5-T MR imaging equipment.

PURPOSE: To evaluate the use of clinical 1.5-T magnetic resonance (MR) imaging equipment to depict the in vivo distribution of iron oxide-labeled human hematopoietic progenitor cells in athymic mice. MATERIALS AND METHODS: This study was approved by the ethical committee, and all women had given consent to donate umbilical cord blood for research. Twenty athymic female Balb/c mice underwent MR imaging before and 1, 4, 24, and 48 hours after intravenous injection of (1-3) x 10(7) human hematopoietic progenitor cells labeled with the superparamagnetic iron oxide particles ferumoxides through simple incubation (n = 10) or P7228 through lipofection (n = 10). Fifteen female Balb/c control mice were examined after intravenous injection of the pure contrast agents (n = 6 for both probes) or nonlabeled cells (n = 3). Signal intensities of liver, spleen, and bone marrow on MR images obtained before and after injection were measured and compared for significant differences by using the t test. MR imaging data were compared with the results of immunostaining against human CD31(+) cells and against the coating of the contrast agents; these results served as the standard of reference. RESULTS: Ferumoxides was internalized into more mature CD34(-) cells but not into CD34(+) stem cells, while P7228 liposomes were internalized into both CD34(-) and CD34(+) cells. After injection of iron oxide-labeled hematopoietic cells, a significant decrease in MR signal intensity was observed in liver and spleen at 1, 4, 24, and 48 hours after injection (P < .05) and in the bone marrow at 24 and 48 hours after injection (P < .05). The signal intensity decrease in bone marrow was significantly stronger after injection of iron oxide-labeled cells compared to controls that received injections of the pure contrast agent (P < .05). Results of histopathologic examination confirmed homing of iron oxide-labeled human progenitor cells in the murine recipient organs. CONCLUSION: The in vivo distribution of intravenously administered iron oxide-labeled hematopoietic progenitor cells can be monitored with 1.5-T MR imaging equipment.

Animals↗

Chest radiography with a digital flat-panel detector: experimental receiver operating characteristic analysis.

PURPOSE: To evaluate the influence of different detector radiation doses and peak kilovoltage settings on diagnostic performance and radiation dose at posteroanterior (PA) chest radiography performed with an amorphous silicon flat-panel detector (FPD). MATERIALS AND METHODS: All examinations were performed by using a digital FPD. PA chest radiographs of an anthropomorphic chest phantom were obtained with detector radiation doses of 2.50 microGy (system speed, 400), 1.56 microGy (speed, 640), and 1.25 microGy (speed, 800) and with peak kilovoltage values of 100, 120, and 140 kVp. Four types of simulated lesions-nodules of different sizes, polylobulated lesions, interstitial-nodular lesions, and interstitial-reticular lesions-were superimposed on the phantom. After four radiologists assessed all of the images, receiver operating characteristics analysis was performed. In addition, the entrance surface dose was measured and the effective dose was calculated. RESULTS: Reduced detector dose led to significantly decreased diagnostic performance in overall lesion detection (P <.05). However, over pulmonary areas only, this effect could not be seen. With use of the same kilovoltage values, reducing the detector dose, even to 1.25 microGy (speed, 800), did not lead to significantly decreased lesion detectability. In terms of diagnostic performance and effective dose, 120 kVp was the most effective. CONCLUSION: Standard PA chest radiographs should still be acquired at a detector dose of 2.50 microGy (speed, 400) with 120 kVp to yield the highest diagnostic performance. However, when the present analysis was focused on the lung fields only, no significant loss in diagnostic performance could be demonstrated, even after a 50% reduction in radiation dose.

Observer Variation↗