PubMed Health⌕ Search

Biomedical subjects

Thomas P Jones

Publications and source records attributed to Thomas P Jones.

4 recordsLinked to original sources

A convenient method for the computer-aided molecular design of carborane containing compounds.

Computer-aided molecular design (CAMD) of carborane containing compounds is of growing interest for scientists involved in boron neutron capture therapy (BNCT) and other pharmaceutical applications. However, the complex organo-metallic structures of carboranes pose difficulties in modeling and docking of these structures. This is the first report of a new strategy for modeling and docking of carborane containing molecules with the readily available software packages HyperChem, SYBYL and FlexX. It is intended as a guide for boron chemists interested in using CAMD of carborane containing agents for medical applications such as BNCT.

Boranes↗

The influence of water vapour on the determination of glutaraldehyde vapour concentrations using an electrochemical fuel cell sensor.

The effects of relative humidity (40-90% RH) and varying glutaraldehyde vapour concentrations (< 0.1 ppm) on the response of an electrochemical fuel cell sensor have been investigated over time (0-400 s). These studies have identified changes in the response of the fuel cell with time after sampling. In particular, it has been found that the maximum cell output for water vapour occurs ca. 10 s after sampling whilst the response to glutaraldehyde occurs much later (> 100 s). For mixtures containing different ratios of water and glutaraldehyde vapours, the time taken to reach maximum fuel cell response varies between 10 and 100 s, depending on the ratio of the two vapours. For instance, glutaraldehyde vapour containing higher % RH has been found to result in shorter times to reach maximum fuel cell response. A comparison was made between measuring glutaraldehyde vapour concentrations in the presence of water vapour at the maximum fuel cell response and also at a fixed interval (240 s) after sampling. Such a comparison resulted in a reduction in the standard error from 36% to 5% for a glutaraldehyde vapour sample (0.023 ppm) measured at different values of relative humidity (40 to 80%). Examination of the effect of the sample volume (30-60 ml) on the response of the fuel cell shows, as expected, an approximate doubling of the fuel cell response. Optimisation of the fuel cell measurement parameters to measure a 60 ml sample leads to a lowering of the limit of detection from 0.083 ppm (for data taken at the maximum cell response) to 0.017 ppm for data measured 240 s after sampling. In the light of recent reductions in the legal limits for exposure to glutaraldehyde, this has important implications for the measurement of glutaraldehyde vapour in the workplace.

Disinfectants↗

Association of biceps tendon tears with rotator cuff abnormalities: degree of correlation with tears of the anterior and superior portions of the rotator cuff.

OBJECTIVE: This study was performed to examine the relationship and association of abnormalities seen in the long head of the biceps brachii tendon to abnormal findings in the rotator cuff. MATERIALS AND METHODS: One hundred eleven patients underwent MR imaging for shoulder pain followed by arthroscopic or open shoulder surgery from January 1997 to December 2000. Patients were identified by a retrospective search, and all consecutive patients having undergone both MR imaging and surgery were included in the patient cohort. Official MR imaging interpretations were compared with operative reports, and all findings were recorded. RESULTS: Twenty-three patients were identified with partial- or full-thickness tears of the long head of the biceps tendon. The sensitivity, specificity, and accuracy of unenhanced MR imaging of the shoulder for detecting these bicipital tears were 52%, 86%, and 79%, respectively. When a tear was present in the biceps tendon, the prevalence of supraspinatous, infraspinatus, and subscapularis tendon tears was 96.2%, 34.6%, and 47.1%, respectively. Patients with biceps tendon tears were significantly more likely to also have subscapularis tendon tears (p < 0.0001) and supraspinatous tendon tears (p < 0.008) than those patients who did not have biceps tendon tears. No significant relationship was found between the presence or absence of a biceps tendon tear and the presence or absence of a infraspinatus or teres minor tendon tear (p = 0.17). CONCLUSION: Tears of the long head of the biceps tendon have a statistically significant association with tears of the anterior and superior rotator cuff and are highly correlated with tears of the supraspinatous and subscapularis tendons. When tears of these tendons are detected, specific attention directed toward the long biceps tendon is warranted to characterize the status of this structure that provides additional stability to the shoulder joint.

Adolescent↗

Your diagnosis? Posterior shoulder dislocation.

Accurate diagnosis of posterior shoulder dislocation requires a high index of suspicion in shoulder trauma patients and proper radiographic evaluation. This case highlights the importance of obtaining axillary views in shoulder trauma cases.

Arthroscopy↗