PubMed Health⌕ Search

Biomedical subjects

Thomas R Pieber

Publications and source records attributed to Thomas R Pieber.

At least 19 recordsLinked to original sources

A New Highly Concentrated Insulin Aspart AT278 (500 U/mL) Demonstrates Ultra-Rapid Pharmacokinetic and Pharmacodynamic Properties in Type 2 Diabetes Regardless of BMI.

AIMS: To evaluate the pharmacokinetics, pharmacodynamics, and safety of a novel U500 insulin aspart formulation (AT278 [500&#x2009;U/mL]; AT278-U500) compared with standard concentration insulin aspart (InsAsp [100&#x2009;U/mL]; InsAsp-U100) and U500 human regular insulin (HumIns [500&#x2009;IU/mL]; HumIns-U500). MATERIALS AND METHODS: This single-centre, randomised, double-blind crossover 12-h euglycaemic clamp study was conducted in 41 overweight and obese people with type 2 diabetes (BMI 25.0-38.7&#x2009;kg/m2) receiving a single subcutaneous dose (0.5&#x2009;U/kg) of AT278-U500 and InsAsp-U100. HumIns-U500 was consecutively studied open label in a 24-h clamp. RESULTS: AT278-U500 exhibited a significantly faster insulin absorption than InsAsp-U100 and HumIns-U500 (t Early50%Cmax: 9&#x2009;min vs. 35&#x2009;min vs. 55&#x2009;min), leading to a significantly higher glucose-lowering effect within the first hour (AUCGIR,0-60min) compared with both InsAsp-U100 (treatment ratio 2.02 [95% CI 1.64; 2.50]) and HumIns-U500 (3.91 [2.89; 5.27]). When divided by median BMI (29.7&#x2009;kg/m2), AUCGIR,0-60min was significantly higher with AT278-U500 in both the low-BMI and high-BMI subgroup compared to InsAsp-U100. Linear regression showed a significant inverse relationship between BMI and AUCGIR,0-60min for InsAsp-U100 (slope -0.142, p&#x2009;<&#x2009;0.0001), whereas AT278-U500 showed no such relationship. Overall insulin exposure was similar for AT278-U500 and InsAsp-U100, while overall glucose-lowering effect was comparable across all three treatments. CONCLUSIONS: AT278-U500 maintains its ultra-rapid onset characteristics independent of BMI, representing the first ultra-rapid U500 option for prandial dosing in insulin-resistant people with type 2 diabetes requiring high-dose therapy. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT05754424.

Humans↗

Rapid online-SPE-MS/MS method for ketoprofen determination in dermal interstitial fluid samples from rats obtained by microdialysis or open-flow microperfusion.

Pharmacokinetic studies of topical ketoprofen formulations using continuous sampling techniques such as microdialysis (MD) or open-flow microperfusion (OFM) require sensitive assays due to small sample volumes. A simple and easy online-SPE-MS/MS method for ketoprofen analysis was developed for both MD and OFM samples obtained from rat dermal tissue. The quantification range is 25-5000 ng/ml with a limit of detection of 3 ng/ml using only 10 microl sample volume. The method is characterized by a simple setup using a short polymeric SPE column (OASIS HLB) for desalting with 1.5 min run times in combination with a sensitive MS detection in negative ESI MRM mode. An easy sample workup procedure was used which enables high throughput analysis of a large number of samples for pharmacokinetic studies. In addition, a commercial available (fenoprofen) as well as an isotopically labelled (deuterated ketoprofen) standard were investigated as potential internal standards. The method was validated according to FDA guidelines for bioanalytical validation in terms of accuracy, intra-batch and inter-batch precision, linearity, matrix effect, recovery and stability for both internal standards. Accuracies were 98-113% (fenoprofen) and 95-108% (deuterated ketoprofen), intra-batch precision was 2-3% R.S.D. (fenoprofen) and 2-6% R.S.D. (deuterated ketoprofen), and inter-batch precision was 2-6% R.S.D. (fenoprofen) and 3-6% R.S.D. (deuterated ketoprofen) over the entire quantification range. The presented method was applied to dermal interstitial fluid samples obtained in a topical administration study of ketoprofen in rats.

Animals↗

Fiber-optic flow-through sensor for online monitoring of glucose.

A new microdialysis-based glucose-sensing system with an integrated fiber-optic hybrid sensor is presented. Design and dimensions of the cell are adapted for its coupling with commercially available microdialysis techniques, thereby providing a new system for continuous glucose monitoring. The glucose level is detected via oxygen consumption which occurs as a consequence of enzymatic reaction between immobilized glucose oxidase and glucose. The use of gas-permeable Tygon tubing ensures complete and constant air-saturation of the measuring fluid in the cell. Nevertheless, a reference oxygen optode is used to detect and to compensate response changes caused by events like bacterial growth, temperature fluctuations, or failure of the peristaltic pump. In contrast to widely used electrochemical sensors, the response of the microdialysis-based fiber-optic glucose sensor is highly selective, making this sensor approach particularly advantageous for continuous glucose monitoring of patients in intensive care units. The effects of flow rate, pH, temperature, and common interferences on the sensor response are presented and discussed in detail. The sensor is evaluated in vitro using a 3-day continuous test in glucose-spiked plasma. The ability to measure glucose in humans is demonstrated by coupling the flow-through cell and commercially available microdialysis catheter CMA60. A 24-h monitoring test using this setup is successfully applied to a healthy volunteer.

Enzymes, Immobilized↗

Poly(cyclooctene)-based monolithic columns for capillary high performance liquid chromatography prepared via ring-opening metathesis polymerization.

Monolithic columns for capillary HPLC were prepared via ring-opening metathesis polymerization (ROMP) from cis-cyclooctene (COE), tris(cyclooct-4-enyl-1-oxy)methylsilane (CL) as monomers, 2-propanol and toluene as porogens and RuCl(2)(Py)(2)(IMesH(2))(CHC(6)H(5)) (Py=pyridine, IMesH(2)=1,3-dimesityl-4,5-dihydroimidazolin-2-ylidene) as initiator within the confines of 200 microm i.d. fused silica columns. For evaluation of the novel monolithic capillary HPLC columns, a protein standard consisting of six proteins in the molecular weight range of 5800-66000 g/mol, i.e. ribonuclease A, insulin, albumin, lysozyme, myoglobin and beta-lactoglobulin, was used. Reproducibility of synthesis was checked by determining the relative standard deviation (RSD) in retention times (t(R)), which was found to be in the range of 2.9-3.9% for all analytes. Variations in polymer kinetics were realized by adding different amounts of free pyridine and had a significant influence on the monolith's morphology, the backpressure and retention times. On the contrary, variations in monomer content and COE to CL ratio showed only minor changes on these parameters. Long-term stability of 1000 runs at 50 degrees C showed excellent stability of the columns and no significant alteration in separation performance was observed in combination with slightly decreased retention times (approx. 1.6-7.2% for all analytes).

Chromatography, High Pressure Liquid↗

Enantioseparation of glycyl-dipeptides by CEC using particle-loaded monoliths prepared by ring-opening metathesis polymerization (ROMP).

Novel particle-loaded monolithic capillary electrochromatography (CEC) phases for chiral separations were prepared via ring-opening metathesis polymerization (ROMP) within the confines of fused silica columns with 200 microm i.d. using norborn-2-ene (NBE), 1,4,4a,5,8,8a-hexahydro-1,4,5,8,exo,endo-dimethanonaphthalene (DMN-H6) as monomers, 2-propanol and toluene as porogens, RuCl2(PCy3)2(CHPh) as initiator and silica-based particles containing the chiral selector. By suspending silica particles bearing the chiral selector in the polymerization mixture, particle-based monoliths are easily prepared. This approach has several advantages compared to particle-based separation media: (i) the concept of particle-based monoliths is broadly applicable, as any silica-based chiral phase can be used; (ii) they are inexpensive to prepare; and (iii) the manufacturing process is very simple, no sophisticated packing procedures or the preparation of end frits are required. To show the usefulness of this concept for chiral CEC, the chiral separation performance of particle-loaded CEC monoliths bearing teicoplanin aglycone, chemically bonded to 3 microm silica gel, was investigated for a set of glycyl-dipeptides. Particle-loaded ROMP CEC monoliths showed good separation performance for glycyl-dipeptides.

Capillary Electrochromatography↗

Recent advances in hereditary sensory and autonomic neuropathies.

PURPOSE OF REVIEW: This review summarizes the genetic advances of hereditary sensory neuropathies and hereditary sensory and autonomic neuropathies, and provides information on phenotype-genotype correlation and on possible underlying pathomechanisms. RECENT FINDINGS: Hereditary sensory neuropathies, also known as hereditary sensory and autonomic neuropathies, are a clinically and genetically heterogeneous group of disorders. These disorders are characterized by prominent sensory loss with acro-mutilating complications and a variable degree of motor and autonomic disturbances. Based on age at onset, clinical features and mode of inheritance, these disorders have originally been subdivided into five types. The identification of eight loci and six disease-causing genes for this group of disorders, however, has shown that this present classification has to be refined. SUMMARY: This review will discuss each of the different loci and genes of these disorders, showing glimpses into a possible underlying pathomechanism leading to the degeneration of sensory and autonomic neurons.

Autonomic Nervous System Diseases↗

Molecular genetics of hereditary sensory neuropathies.

Hereditary sensory neuropathies (HSN), also known as hereditary sensory and autonomic neuropathies (HSAN), are a clinically and genetically heterogeneous group of disorders. They are caused by neuronal atrophy and degeneration, predominantly affecting peripheral sensory and autonomic neurons. Both congenital and juvenile to adulthood onset is possible. Currently, the classification of the HSN depends on the mode of inheritance, age at onset, and clinical presentation. Hallmark features are progressive sensory loss, chronic skin ulcers, and other skin abnormalities. Spontaneous fractures and neuropathic arthropathy are frequent complications and often necessitate amputations. Autonomic features vary between different subgroups. Distal muscle weakness and wasting may be present and is sometimes so prominent that it becomes difficult to distinguish HSN from Charcot-Marie-Tooth syndrome. Recent major advances in molecular genetics have led to the identification of seven gene loci and six-disease causing genes for autosomal-dominant and autosomal-recessive HSN. These genes have been shown to play roles in lipid metabolism and the regulation of intracellular vesicular transport, but also a presumptive transcriptional regulator, a nerve growth factor receptor, and a nerve growth factor have been described among the causative genes in HSN. Nevertheless, it remains unclear how mutations in the known genes lead to the phenotype of HSN. In this review, we summarize the recent progress of the molecular genetics of the HSN and the implicated genes.

Acyltransferases↗

Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients.

OBJECTIVE: To evaluate a fully automated algorithm for the establishment of tight glycemic control in critically ill patients and to compare the results with different routine glucose management protocols of three intensive care units (ICUs) across Europe (Graz, Prague, and London). RESEARCH DESIGN AND METHODS: Sixty patients undergoing cardiac surgery (age 67 +/- 9 years, BMI 27.7 +/- 4.9 kg/m2, 17 women) with postsurgery blood glucose levels >120 mg/dl (6.7 mmol/l) were investigated in three different ICUs (20 per center). Patients were randomized to either blood glucose management (target range 80-110 mg/dl [4.4-6.1 mmol/l]) by the fully automated model predictive control (MPC) algorithm (n = 30, 10 per center) or implemented routine glucose management protocols (n = 30, 10 per center). In all patients, arterial glucose was measured hourly to describe the glucose profile until the end of the ICU stay but for a maximum period of 48 h. RESULTS: Compared with routine protocols, MPC treatment resulted in a significantly higher percentage of time within the target glycemic range (% median [min-max]: 52 [17-92] vs. 19 [0-71]) over 0-24 h (P < 0.01). Improved glycemic control with MPC treatment was confirmed in patients remaining in the ICU for 48 h (0-24 h: 50 [17-71] vs. 21 [4-67], P < 0.05, and 24-48 h: 65 [38-96] vs. 25 [8-79], P < 0.05, for MPC [n = 16] vs. routine protocol [n = 13], respectively). Two hypoglycemic events (<54 mg/dl [3.0 mmol/l]) were observed with routine protocol treatment. No hypoglycemic event occurred with MPC. CONCLUSIONS: The data suggest that the MPC algorithm is safe and effective in controlling glycemia in critically ill postsurgery patients.

Aged↗

On-the-fly form generation and on-line metadata configuration--a clinical data management Web infrastructure in Java.

In this paper we describe the approach to build a web-based clinical data management infrastructure on top of an entity-attribute-value (EAV) database which provides for flexible definition and extension of clinical data sets as well as efficient data handling and high performance query execution. A "mixed" EAV implementation provides a flexible and configurable data repository and at the same time utilizes the performance advantages of conventional database tables for rarely changing data structures. A dynamically configurable data dictionary contains further information for data validation. The online user interface can also be assembled dynamically. A data transfer object which encapsulates data together with all required metadata is populated by the backend and directly used to dynamically render frontend forms and handle incoming data. The "mixed" EAV model enables flexible definition and modification of clinical data sets while reducing performance drawbacks of pure EAV implementations to a minimum. The system currently is in use in an electronic patient record with focus on flexibility and a quality management application (www.healthgate.at) with high performance requirements.

Austria↗

Evaluation of ring-opening metathesis polymerization (ROMP)-derived monolithic capillary high performance liquid chromatography columns.

Novel monolithic capillary HPLC columns were prepared via ring opening metathesis polymerization (ROMP) within the confines of fused silica columns with 200 microm i.d. using norborn-2-ene (NBE), 1,4,4a,5,8,8a-hexahydro-1,4,5,8, exo, endo-dimethanonaphthalene (DMN-H6) as monomers, 2-propanol and toluene as porogens and RuCl2(PCy3)2(CHPh) as initiator. Using the monolithic capillary HPLC columns, different sets of analytes (i.e. standard systems) were used for the evaluation of the monolithic columns: (i) a protein standard consisting of six proteins in the range of 5000-66 000 g/mol, (ii) an insulin-albumin standard, and (iii) a peptide standard obtained from a tryptic digest of cytochrome C. With these three different standard systems the reproducibility of synthesis in terms of separation performance proved to be 1-2% relative standard deviation in tR. Variation of polymerization parameters had a significant influence on the monolithic morphology and therefore separation efficiency and back pressure. The maximum analytical loading capacity of ROMP-derived monolithic capillary columns for albumin was found to be 30-125 ng, depending on the monomer content. Long-term stability studies showed no alteration in separation performance.

Bridged Bicyclo Compounds↗

Systematic review and meta-analysis of short-acting insulin analogues in patients with diabetes mellitus.

BACKGROUND: This article compares the effect of treatment with short-acting insulin (SAI) analogues vs regular insulin on glycemic control, hypoglycemic episodes, quality of life, and diabetes-specific complications. METHODS: Electronic searches (Cochrane Library, MEDLINE, and EMBASE) and additional searching (pharmaceutical companies, experts, approval agencies, abstracts of diabetology meetings) were performed. Two reviewers independently screened randomized controlled trials to determine inclusion. RESULTS: Forty-two randomized controlled trials that assessed the effect of SAI analogues vs regular insulin in 7933 patients with type 1 diabetes mellitus, type 2 diabetes mellitus, and gestational diabetes mellitus were identified. The weighted mean difference between hemoglobin A(1c) values obtained using SAI analogues and regular insulin was -0.12% (95% confidence interval [CI], -0.17% to -0.07%) for adult patients with type 1 diabetes mellitus and -0.02% (95% CI, -0.10% to 0.07%) for patients with type 2 diabetes mellitus. The standardized mean difference for overall hypoglycemia (episodes per patient per month) was -0.05 (95% CI, -0.22 to 0.11) and -0.04 (95% CI, -0.12 to 0.04) comparing SAI analogues with regular insulin in adult patients with type 1 and type 2 diabetes mellitus, respectively. No differences between treatments were observed in children with type 1 diabetes, pregnant women with type 1 diabetes mellitus, and women with gestational diabetes. Concerning quality of life, improvement was observed only in open-label studies in patients with type 1 diabetes mellitus. No differences were seen in a double-blinded study of patients with type 1 or in the studies of patients with type 2 diabetes mellitus. CONCLUSION: Our analysis suggests only a minor benefit to hemoglobin A(1c) values in adult patients with type 1 diabetes mellitus but no benefit in the remaining population with type 2 or gestational diabetes from SAI analogue treatment.

Adolescent↗

LC/MS/MS method for quantitative determination of long-chain fatty acyl-CoAs.

Long-chain acyl-CoA esters (LCACoAs) are activated lipid species that represent key substrates in lipid metabolism. The relationship between lipid metabolism disorders and type 2 diabetes has attracted much attention to this class of metabolites. This paper presents a highly sensitive and robust on-line LC/MS(2) procedure for quantitative determination of LCACoAs from rat liver. A fast SPE method has been developed without the need for time-consuming evaporation steps for sample preparation. LCACoAs were separated with high resolution using a C18 reversed-phase column at high pH (10.5) with an ammonium hydroxide and acetonitrile gradient. Five LCACoAs (C16:0, C16:1, C18:0 C18:1, C18:2) were quantified by selective multireaction monitoring using a triple quadrupole mass spectrometer in positive electrospray ionization mode. It is possible to perform a neutral loss scan of 507 for lipid profiling of complex LCACoA mixtures in tissue extracts. The method presented was validated according to ICH guidelines for quantitative determination of five LCACoAs for physiological concentrations in 100-200 mg of tissue with accuracies ranging from 94.8 to 110.8%, interrun precisions between 2.6 and 12.2%, and intrarun precisions between 1.2 and 4.4%. Due to the high sensitivity of the developed method, the amount of tissue biopsied for reliable quantification can be reduced. This may be advantageous in the quantification of LCACoAs in humans.

Acyl Coenzyme A↗

Measurement of interstitial insulin in human adipose and muscle tissue under moderate hyperinsulinemia by means of direct interstitial access.

Insulin's action to stimulate glucose utilization is determined by the insulin concentration in interstitial fluid (ISF) of insulin-sensitive tissues. The concentration of interstitial insulin has been measured in human subcutaneous adipose tissue and skeletal muscle, however, never in parallel. The aim of this study was to compare interstitial insulin levels between both tissue beds by simultaneous measurements and to verify and quantify low peripheral ISF insulin fractions as found during moderate hyperinsulinemia. Nine healthy subjects (27.2 +/- 0.8 yr) were investigated. A euglycemic-hyperinsulinemic clamp was started with a primed-constant intravenous insulin infusion of 1 mU x kg(-1) x min(-1). For direct access to ISF, macroscopically perforated open-flow microperfusion catheters were inserted in both tissues. During steady-state conditions (9.5 h), interstitial effluents were collected in 30-min fractions using five different insulin concentrations in the inflowing perfusates ("no net flux" protocol). Regression analysis of insulin concentrations in perfusates and effluents yielded the relative recovery and the perfusate insulin concentration, which was in equilibrium with the surrounding tissue. Thus, in subcutaneous adipose tissue and skeletal muscle, the mean ISF-to-serum insulin level was calculated as 21.0% [95% confidence interval (CI) 17.5-24.5] and 26.0% (95% CI 19.1-32.8; P = 0.14), respectively. Recoveries for insulin averaged 51 and 64%, respectively. The data suggest that the concentrations of insulin arising in healthy subjects at the level of ISF per se are comparable between subcutaneous adipose and skeletal muscle tissue. The low interstitial insulin fractions seem to confirm reports of low peripheral insulin levels during moderate insulin clamps.

Adipose Tissue↗

Insulin kinetics in type-I diabetes: continuous and bolus delivery of rapid acting insulin.

We investigated insulin lispro kinetics with bolus and continuous subcutaneous insulin infusion (CSII) modes of insulin delivery. Seven subjects with type-1 diabetes treated by CSII with insulin lispro have been studied during prandial and postprandial conditions over 12 hours. Eleven alternative models of insulin kinetics have been proposed implementing a number of putative characteristics. We assessed 1) the effect of insulin delivery mode, i.e., bolus or basal, on the insulin absorption rate, the effects of 2) insulin association state and 3) insulin dose on the rate of insulin absorption, 4) the remote insulin effect on its volume of distribution, 5) the effect of insulin dose on insulin disappearance, 6) the presence of insulin degradation at the injection site, and finally 7) the existence of two pathways, fast and slow, of insulin absorption. An iterative two-stage parameter estimation technique was used. Models were validated through assessing physiological feasibility of parameter estimates, posterior identifiability, and distribution of residuals. Based on the principle of parsimony, best model to fit our data combined the slow and fast absorption channels and included local insulin degradation. The model estimated that 67(53-82)% [mean (interquartile range)] of delivered insulin passed through the slow absorption channel [absorption rate 0.011(0.004-0.029) min(-1)] with the remaining 33% passed through the fast channel [absorption rate 0.021(0.011-0.040) min(-1)]. Local degradation rate was described as a saturable process with Michaelis-Menten characteristics [VMAX = 1.93(0.62 - 6.03) mU min(-1), KM = 62.6(62.6 - 62.6) mU]. Models representing the dependence of insulin absorption rate on insulin disappearance and the remote insulin effect on its volume of distribution could not be validated suggesting that these effects are not present or cannot be detected during physiological conditions.

Adult↗

A double-blind, randomized, dose-response study investigating the pharmacodynamic and pharmacokinetic properties of the long-acting insulin analog detemir.

OBJECTIVE: To investigate the pharmacodynamic profile and duration of action for five subcutaneous doses of insulin detemir (0.1, 0.2, 0.4, 0.8, and 1.6 units/kg; 1 unit = 24 nmol) and one subcutaneous dose of NPH insulin (0.3 IU/kg; 1 IU = 6 nmol). RESEARCH DESIGN AND METHODS: This single-center, randomized, double-blind, six-period, crossover study was carried out as a 24-h isoglycemic clamp (7.2 mmol/l) in 12 type 1 diabetic patients. RESULTS: Duration of action for insulin detemir was dose dependent and varied from 5.7, to 12.1, to 19.9, to 22.7, to 23.2 h for 0.1, 0.2, 0.4, 0.8, and 1.6 units/kg, respectively. Interpolation of the dose-response relationships for AUC(GIR) (area under the glucose infusion rate curve) revealed that a detemir dose of 0.29 units/kg would provide the same effect as 0.3 IU/kg NPH but has a longer duration of action (16.9 vs. 12.7 h, respectively). Lower between-subject variability was observed for insulin detemir on duration of action (0.4 units/kg insulin detemir vs. 0.3 IU/kg NPH, P < 0.05) and GIR(max) (maximal glucose infusion rate) (0.2 and 0.4 units/kg insulin detemir vs. 0.3 IU/kg NPH, both P < 0.05). Assessment of endogenous glucose production (EGP) and peripheral glucose uptake (PGU) resulted in an AOC(EGP) (area over the EGP curve) of 636 mg/kg (95% CI 279-879) vs. 584 (323-846) and an AUC(PGU) (area under the PGU curve) of 173 (47-316) vs. 328 (39-617) for 0.29 units/kg detemir vs. 0.3 IU/kg NPH, respectively. CONCLUSIONS: This study shows that insulin detemir provides a flat and protracted pharmacodynamic profile.

Adolescent↗

Interstitial glucose kinetics in subjects with type 1 diabetes under physiologic conditions.

We investigated the dynamic relationship between interstitial glucose (IG) in the subcutaneous adipose tissue and plasma glucose (PG) during physiologic conditions in type 1 diabetes mellitus (T1DM). Nine subjects with T1DM (5/4 M/F; age, 33 +/- 13 years; body mass index, 26.6 +/- 4.3 kg/m(2); glycosylated hemoglobin [HbA(1c)], 8.6% +/- 0.9%; mean +/- SD) treated by continuous subcutaneous insulin infusion (CSII) with insulin lispro were studied over 12 hours after a standard meal (40 g carbohydrate [CHO]) and prandial insulin. IG was measured by open flow microperfusion. Nine compartment models were postulated to account for temporal variations in the IG/PG ratio. The models differed in the inclusion of physiologically motivated alterations of pathways entering/leaving the IG compartment in the adipose tissue. The best model included zero order (constant) glucose disposal from the interstitial fluid (ISF) and insulin-stimulated glucose transfer from plasma to the ISF. The former effect is expressed by a positive association between the IG/PG ratio and PG, eg, a decrease in PG from 9 to 3.3 mmol/L lowers the IG/PG ratio by 0.1. The latter effect results in the IG/PG ratio to be increased by 0.03 per 10 mU/L of plasma insulin. We were not able to detect the stimulatory effect of insulin on glucose disappearance from the ISF. In conclusion, we developed and quantified a model of IG kinetics in the adipose tissue applicable to physiologic conditions in subjects with T1DM.

Adipose Tissue↗

Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcutaneously administered short-acting insulin Lispro and gut absorption. The controller uses Bayesian parameter estimation to determine time-varying model parameters. Moving target trajectory facilitates slow, controlled normalization of elevated glucose levels and faster normalization of low glucose values. The predictive capabilities of the model have been evaluated using data from 15 clinical experiments in subjects with type 1 diabetes. The experiments employed intravenous glucose sampling (every 15 min) and subcutaneous infusion of insulin Lispro by insulin pump (modified also every 15 min). The model gave glucose predictions with a mean square error proportionally related to the prediction horizon with the value of 0.2 mmol L(-1) per 15 min. The assessment of clinical utility of model-based glucose predictions using Clarke error grid analysis gave 95% of values in zone A and the remaining 5% of values in zone B for glucose predictions up to 60 min (n = 1674). In conclusion, adaptive nonlinear model predictive control is promising for the control of glucose concentration during fasting conditions in subjects with type 1 diabetes.

Blood Glucose↗