PubMed Health⌕ Search

Biomedical subjects

Thomas Schertler

Publications and source records attributed to Thomas Schertler.

14 recordsLinked to original sources

In-vivo flow simulation in coronary arteries based on computed tomography datasets: feasibility and initial results.

The purpose of this paper was to non-invasively assess hemodynamic parameters such as mass flow, wall shear stress (WSS), and wall pressure with computational fluid dynamics (CFD) in coronary arteries using patient-specific data from computed tomography (CT) angiography. Five patients (two without atherosclerosis, three with atherosclerosis) underwent retrospectively electrocardiogram (ECG) gated 16-detector row CT using ECG-pulsing and geometric models of coronary arteries were reconstructed for CFD analysis. Blood flow was considered laminar, incompressible, Newtonian, and pulsatile. The mass flow, WSS, and wall pressure were quantified and flow patterns were visualized. The wall pressure continuously decreased towards distal segments and showed pressure drops in stenotic segments. In coronary segments without atherosclerotic wall changes, WSS remained low, even during phases of high flow velocity, whereas in atherosclerotic vessels, the WSS was elevated already at low flow velocities. Stenoses and post-stenotic dilatations led to flow acceleration and rapid deceleration, respectively, including a distortion of flow. Areas of high WSS and high flow velocities were found adjacent to plaques, with values correlating with the degree of stenosis. CFD provided detailed mass flow measurements. CFD analysis is feasible in normal and atherosclerotic coronary arteries and provides the rationale for further investigation of the links between hemodynamic parameters and the significance of coronary stenoses.

Aged↗

Visualization of congenital thoracic vascular anomalies using multi-detector row computed tomography and two- and three-dimensional post-processing.

Anomalies of the vascular system are caused by false embryogenesis and are therefore present from birth. Single-detector row spiral computed tomography angiography (CTA) and multi-detector row computed tomography angiography (MDCTA) have gained increasing importance in the non-invasive assessment of vascular pathologies and replace conventional angiography in many cases. High-resolution volumetric datasets that are acquired during a single breath-hold give the possibility of two- (2D) and three-dimensional (3D)-post-processing. Due to post-processing, even complex vascular malformations are visualized in an understandable way. Furthermore, CTA, in contrast to conventional angiography, depicts not only the vascular structures but also allows assessment of the surrounding anatomical structures. We present cases of rare congenital anomalies of the thoracic vessels using MDCT with special respect to 2D- and 3D-post-processing.

Algorithms↗

Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control.

The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1+/-11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14+/-9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter > or =1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3+/-3.9 kg/m2 (range 22.4-36.3 kg/m2), mean heart rate during CT was 70.3+/-14.2 bpm (range 47-102 bpm), and mean Agatston score was 821+/-904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68+/-0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.

Adult↗

Comparison of retrospectively ECG-gated and nongated MDCT of the chest in an emergency setting regarding workflow, image quality, and diagnostic certainty.

PURPOSE: This study aims to assess the influence of ECG-gated acquisition on workflow and to compare image quality and diagnostic certainty for retrospectively ECG-gated and nongated multidetector computed tomography of the chest in the emergency suite. MATERIALS AND METHODS: Thirty-two consecutive patients were referred for both an ECG-gated and a nongated CT to rule out traumatic thoracic injury (n=15) or acute aortic dissection (n=17). The time from the start of the transportation from the emergency suite to the CT room until the start of the CT scan was recorded. Using a scoring system, the image quality of axial images and multiplanar reformats, the presence of disease, and the subjective diagnostic certainty were assessed with regard to the vascular structures, the bone structures, and the lung parenchyma. RESULTS: The time needed for transportation and patient preparation was 12.1+/-1.7 min (8.1-14.5 min). The motion artifacts of the thoracic aorta and the supra-aortic vessels were significantly reduced in the ECG-gated data acquisition compared with the nongated technique (P<0.001). Subjective diagnostic certainty for assessment of the aorta was significantly better using ECG gating. The image quality of the lung parenchyma (P<0.005), the spine (P<0.005), and the ribs (P<0.002) was inferior in the ECG-gated data sets but did not compromise the detection rate of traumatic lesions and fractures. CONCLUSION: Performing ECG gating in the emergency room did not slow down the diagnostic workup. ECG-gated acquisition performed better in the assessment of the aorta, but image quality for lung and bone structures was slightly reduced. Further studies are required to assess the influence of the imaging technique on the diagnostic outcome.

Aorta, Thoracic↗

Aortoiliac and lower extremity arteries assessed with 16-detector row CT angiography: prospective comparison with digital subtraction angiography.

PURPOSE: To prospectively compare the accuracy of 16-detector row computed tomographic (CT) angiography with conventional digital subtraction angiography (DSA) as the reference standard in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease. MATERIALS AND METHODS: This study was approved by the institutional review board, and informed consent was obtained. A total of 39 consecutive patients (27 men [mean age, 66 years] and 12 women [mean age, 64 years]) with peripheral arterial disease underwent both conventional DSA and 16-detector row CT angiography. For data analysis, the arterial vascular system was divided into 35 segments. A total of 1365 arterial segments were analyzed for arterial stenosis by two independent blinded readers using a four-point grading system (grade 1, <10% luminal narrowing; grade 2, 10%-49% luminal narrowing; grade 3, 50%-99% luminal narrowing; grade 4, occlusion). Interobserver agreements were calculated by using kappa statistics. A third independent blinded reader assessed possible reasons for disagreements between 16-detector row CT angiographic findings and conventional DSA findings. Effective radiation dose was calculated for both imaging modalities. RESULTS: Sixteen-detector row CT angiographic and conventional DSA findings were diagnostic in all vascular segments. Compared with conventional DSA, the sensitivity and specificity of 16-detector row CT angiography with regard to detection of hemodynamically significant stenosis in all 35 arterial segments were 96% and 97%, respectively, for both readers. Readers 1 and 2 overestimated arterial stenosis in 42 (3%) and 34 (2%) arterial segments, respectively, and underestimated arterial stenosis in 13 (1%) and 10 (1%) arterial segments, respectively. Interobserver agreement was excellent (kappa = 0.84-1.00). Presence of anteroposteriorly located luminal narrowing and extensive vascular wall calcification were considered main reasons for disagreements between imaging modalities. Effective radiation dose was lower for 16-detector row CT angiography (1.6-3.9 mSv) than for conventional DSA (6.4-16.0 mSv). CONCLUSION: Sixteen-detector row CT angiography is an accurate and reliable noninvasive alternative to conventional DSA in the assessment of aortoiliac and lower extremity arteries in patients with peripheral arterial disease.

Adult↗

Coarctation and aorto-aortic bypass: three-dimensional post-processing using multidetector row computed tomography.

We present the case of a 61-year-old man with a history of dyspnea and disparity in blood pressure of the arms and legs due to a stenotic biscupid aortic valve and a hemodynamically relevant restenosis of a resected coarctation. The coarctation was treated with an extra-anatomic transdiaphragmal aorto-aortic bypass graft. At the same time, the biscupid aortic valve was replaced. Postoperative follow-up contrast-enhanced multidetector row computed tomography (MDCT) and three-dimensional (3D) postprocessing of the axial data sets using the volume-rendering technique was performed. This case of complex vascular structures demonstrates the potency of MDCT combined with the 3D visualization technique.

Aortic Coarctation↗

Image quality of volume rendering of the bronchial tree: Kymogram-gated versus retrospectively ECG-gated and non-gated multi-row detector CT.

RATIONALE AND OBJECTIVE: To compare the image quality of three different heart-cycle-synchronized computed tomography (CT) reconstruction algorithms for volume-rendered (VR) 3D visualization of the bronchial tree. MATERIALS AND METHODS: Kymogram-gated, retrospectively ECG-gated, and non-ECG-gated reconstructions of the bronchial tree were performed from 4-detector-row CT data in 10 subjects. The raw data were reconstructed in 10 phases of the cardiac cycle using ECG-gated and kymogram-gated technique, respectively. For both reconstructions, the optimal artifact-free diastolic phase was determined. VR reconstructions of the bronchial tree were generated from these two data sets and from the non-gated data. Stairstep artifacts of the main bronchi, artifacts in the lung parenchyma, and the extent of bronchial tree visualization were rated by two blinded, independent readers. RESULTS: Kymogram-gated reconstruction showed stairstep artifacts in the main bronchi to the same extent as non-gated reconstruction, but less compared to ECG-gated reconstruction (P < .001). Artifacts in the lung parenchyma were similar with kymogram-gated and non-gated reconstruction, but less compared to ECG-gated reconstruction (P < 0.01). Kymogram-gated reconstruction showed no differences in visualization of segmental and subsegmental bronchi compared to ECG-gated reconstruction, but was inferior to the non-gated reconstruction (P < 0.05). CONCLUSION: Kymogram-gated reconstruction of CT data results in fewer artifacts when compared to the ECG-gated algorithm. Best visualization of the bronchial tree at a low artifact level is obtained with non-gated CT data. It remains therefore the method of choice for VR 3D data post-processing of the bronchial tree.

Adult↗

Sixteen-detector row CT angiography for lower-leg arterial occlusive disease: analysis of section width.

Institutional review board approval and written informed consent from all patients were obtained. Diagnostic accuracy of three reconstructions of 16-detector row computed tomographic (CT) angiography data with different section widths and increments (2.0 and 1.0 mm [CT data set 1], 1.0 and 0.5 mm [CT data set 2], and 0.75 and 0.4 mm [CT data set 3]) was compared with that of digital subtraction angiography (DSA) in 163 arterial segments in 17 patients with occlusive peripheral arterial disease (PAD). Arterial visibility was superior with CT as compared with DSA (P < .008). Sensitivity for stenosis detection did not differ between the CT reconstructions, whereas specificity was significantly improved when CT data set 3 was used (P < .017). Stenosis length did not differ significantly between CT angiography and DSA. Accuracy of stenosis detection was 88.2%, 90.8%, and 96.1% with CT data sets 1, 2, and 3, respectively. CT angiography has excellent diagnostic accuracy in the assessment of lower-leg PAD provided that the thinnest possible section width is used.

Aged↗

Interosseous ligament tears of the wrist: comparison of multi-detector row CT arthrography and MR imaging.

PURPOSE: To compare the accuracy of multi-detector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers. MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multi-detector row CT arthrography was performed after tricompartmental injection of 3-6 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multi-detector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted kappa values for interobserver agreement were calculated for both imaging modalities. RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P = .62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P = .02). Interobserver agreement was better for multi-detector row CT arthrography (kappa = 0.37-0.78) than for MR imaging (kappa = -0.33 to -0.10). CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multi-detector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments.

Aged↗

Effects of ECG gating and postprocessing techniques on 3D MDCT of the bronchial tree.

OBJECTIVE: Our goal was to determine the impact of ECG gating and different postprocessing techniques on 3D imaging of the bronchial tree. SUBJECTS AND METHODS. Retrospective ECG-gated MDCT and non-ECG-gated MDCT of the chest were performed in 25 patients. ECG-gated MDCT data were reconstructed mid diastole using a fixed interval of -400 msec in 25 patients and then additionally at -200, -300, and -500 msec in 10 of those patients. Shaded surface display and volume rendering of the bronchial tree combined with virtual bronchoscopy were performed using all data sets. The extent of bronchial tree visualization in shaded surface display-virtual bronchoscopy and volume rendering-virtual bronchoscopy and the presence of artifacts in volume-rendered images were scored by three blinded reviewers. The effective radiation doses of the ECG-gated and nongated acquisitions were compared. RESULTS: The summary scores of all bronchial segments for gated shaded surface display-virtual bronchoscopy and gated volume rendering-virtual bronchoscopy did not differ significantly. The summary scores for nongated shaded surface display-virtual bronchoscopy and nongated volume rendering-virtual bronchoscopy were not significantly different. Non-gated acquisition yielded significantly better visualization of the bronchial tree for both post-processing techniques, regardless of the time interval used for reconstruction of the ECG-gated series. Artifact scores in volume-rendered images were significantly higher for ECG-gated MDCT compared with nongated MDCT. Effective radiation dose was significantly higher for the ECG-gated acquisition. CONCLUSION: Given the advantage of volume rendering for representing the entire data set and given the lower radiation dose and better 3D image quality of nongated acquisition, volume rendering performed on nongated MDCT data is the method of choice for 3D visualization of the bronchial tree.

Bronchography↗

Effects of bisoprolol fumarate on left ventricular size, function, and exercise capacity in patients with heart failure: analysis with magnetic resonance myocardial tagging.

BACKGROUND: Recent data suggest that beta-blockers can be beneficial in subgroups of patients with chronic heart failure (CHF). For metoprolol and carvedilol, an increase in ejection fraction has been shown and favorable effects on the myocardial remodeling process have been reported in some studies. We examined the effects of bisoprolol fumarate on exercise capacity and left ventricular volume with magnetic resonance imaging (MRI) and applied a novel high-resolution MRI tagging technique to determine myocardial rotation and relaxation velocity. METHODS: Twenty-eight patients (mean age, 57 +/- 11 years; mean ejection fraction, 26 +/- 6%) were randomized to bisoprolol fumarate (n = 13) or to placebo therapy (n = 15). The dosage of the drugs was titrated to match that of the the Cardiac Insufficiency Bisoprolol Study protocol. Hemodynamic and gas exchange responses to exercise, MRI measurements of left ventricular end-systolic and end-diastolic volumes and ejection fraction, and left ventricular rotation and relaxation velocities were measured before the administration of the drug and 6 and 12 months later. RESULTS: After 1 year, heart rate was reduced in the bisoprolol fumarate group both at rest (81 +/- 12 before therapy versus 61 +/- 11 after therapy; P <.01) and peak exercise (144 +/- 20 before therapy versus 127 +/- 17 after therapy; P <.01), which indicated a reduction in sympathetic drive. No differences were observed in heart rate responses in the placebo group. No differences were observed within or between groups in peak oxygen uptake, although work rate achieved was higher (117.9 +/- 36 watts versus 146.1 +/- 33 watts; P <.05) and exercise time tended to be higher (9.1 +/- 1.7 minutes versus 11.4 +/- 2.8 minutes; P =.06) in the bisoprolol fumarate group. A trend for a reduction in left ventricular end-diastolic volume (-54 mL) and left ventricular end-systolic volume (-62 mL) in the bisoprolol fumarate group occurred after 1 year. Ejection fraction was higher in the bisoprolol fumarate group (25.0 +/- 7 versus 36.2 +/- 9%; P <.05), and the placebo group remained unchanged. Most changes in volume and ejection fraction occurred during the latter 6 months of treatment. With myocardial tagging, insignificant reductions in left ventricular rotation velocity were observed in both groups, whereas relaxation velocity was reduced only after bisoprolol fumarate therapy (by 39%; P <.05). CONCLUSION: One year of bisoprolol fumarate therapy resulted in an improvement in exercise capacity, showed trends for reductions in end-diastolic and end-systolic volumes, increased ejection fraction, and significantly reduced relaxation velocity. Although these results generally confirm the beneficial effects of beta-blockade in patients with chronic heart failure, they show differential effects on systolic and diastolic function.

Adrenergic beta-Antagonists↗

Effects of exercise training on left ventricular volumes and function in patients with nonischemic cardiomyopathy: application of magnetic resonance myocardial tagging.

BACKGROUND: Exercise training is now an accepted component of the therapeutic regimen in patients with heart failure and underlying ischemia, but few data are available on the effects of training in patients with nonischemic dilated cardiomyopathy. METHODS: Twenty-four patients (mean age 55 +/- 9 years, mean ejection fraction 26.6% +/- 10%) were randomized to an exercise (n = 12) or a control (n = 12) group. Patients in the exercise group underwent 5 45-minute sessions of supervised training per week. Before and after the 2-month study period, exercise testing with respiratory gas exchange and lactate analysis was performed, left ventricular volumes and ejection fraction were measured with magnetic resonance imaging, and left ventricular rotation and relaxation velocities were measured with a novel magnetic resonance imaging tagging technique. RESULTS: Training resulted in increases in peak oxygen uptake (VO2) (21.7 +/- 4 mL/kg/min to 25.3 +/- 5 mL/kg/min, P <.05) and VO2 at the lactate threshold (12.8 +/- 4 mL/kg/min to 19.0 +/- 5 mL/kg/min, P <.01). No differences were observed within or between groups in left ventricular end-diastolic volume, end-systolic volume, or ejection fraction. Velocity of left ventricular rotation during systole was unchanged in both groups, and relaxation velocity was higher after training in the exercise group (21.2 +/- 5 degrees/s versus 29.7 +/- 12 degrees/s, P <.05). CONCLUSION: Training resulted in increases in peak VO2 and VO2 at the lactate threshold. Left ventricular volumes and systolic function (ie, ejection fraction and rotation velocity) were unchanged with training, suggesting that training in patients with dilated cardiomyopathy does not lead to further myocardial damage. However, the increase in relaxation velocity after exercise training indicates an improvement in diastolic function. The latter finding suggests an additional potential benefit of exercise training in patients with dilated cardiomyopathy.

Cardiac Output, Low↗

Transvenous biopsy of cavo-atrial tumors with the Quick-Core needle.

A variant application of the renal Quick-Core needle in 3 patients with cavo-atrial tumors is reported. In all 3 patients either a transjugular or transfemoral venous biopsy approach with this device yielded sufficient tissue for histological diagnosis at the first attempt. Bioptic diagnoses were confirmed either by surgery or radiological and clinical response to a specific chemotherapy. There were no procedure-related complications.

Aged↗

Vascular emergencies of the thorax after blunt and iatrogenic trauma: multi-detector row CT and three-dimensional imaging.

Multi-detector row computed tomographic (CT) angiography is an effective modality for vascular imaging in the thorax. It allows acquisition of high-resolution data sets during a single breath hold, making it the preferred method for evaluation of patients with acute vascular disease. In contrast to conventional angiography, multirow CT angiography not only depicts the vessels but also allows assessment of adjacent structures. Multirow CT angiography with two- and three-dimensional reformation can be used to diagnose vascular emergencies of the thorax after blunt and iatrogenic trauma. These include incomplete and complete aortic rupture; traumatic aortic dissection; arterial dissection and rupture after minor trauma in patients with Ehlers-Danlos syndrome; traumatic intramural hematoma; pseudoaneurysm after endovascular repair; injuries due to Swan-Ganz catheters; complications of central venous cannulation, pacemaker implantation, and percutaneous pericardial drainage; and foreign-body embolism. The diagnoses can be established with multirow CT angiography in the emergency department. Thus, the time to diagnosis can be considerably decreased by obviating conventional angiography. Knowledge of the CT findings in various vascular conditions is essential to make use of multirow CT angiography in combination with two- and three-dimensional reformation as an efficient and accurate diagnostic tool in emergency radiology.

Adult↗