PubMed Health⌕ Search

Biomedical subjects

Thomas Thundat

Publications and source records attributed to Thomas Thundat.

9 recordsLinked to original sources

Glucose biosensor based on the microcantilever.

Diagnosis and management of diabetes require quantitative and selective detection of blood glucose levels. We report a technique for micromechanical detection of biologically relevant glucose concentrations by immobilization of glucose oxidase (GOx) onto a microcantilever surface. Microfabricated cantilevers have traditionally found utility in atomic force microscope imaging. During the past decade, however, microcantilevers have been increasingly used as transducers in chemical-sensing systems. This paper describes the combination of this technology with enzyme specificity to construct a highly selective glucose biosensor. The enzyme-functionalized microcantilever undergoes bending due to a change in surface stress induced by the reaction between glucose in solution and the GOx immobilized on the cantilever surface. Experiments were carried out under flow conditions. The common interferences for glucose detection in other detection schemes have been tested and have shown to have no effect on the measurement of blood glucose level by this technique.

Biosensing Techniques↗

Detection of heavy metal ions using protein-functionalized microcantilever sensors.

Microcantilevers functionalized with metal-binding protein, AgNt84-6, are demonstrated to be sensors for the detection of heavy metal ions like Hg(2+) and Zn(2+). AgNt84-6, a protein that has the ability to bind multiple atoms of Ni(2+), Zn(2+), Co(2+), Cu(2+), Cd(2+) and Hg(2+) was attached to the gold-coated side of silicon nitride cantilevers via linker groups. Upon exposure to 0.1 mM HgCl(2) and 0.1 mM ZnCl(2) solutions, the microcantilevers underwent bending corresponding to an expanding gold side. Exposure to a 0.1 mM solution of MnCl(2) solution did not result in a similar bending indicating a weak or no interaction of Mn(2+) ions with the AgNt84-6 protein. The microcantilever bending data were consistent with data from electrophoresis carried out on SDS-PAGE gels containing metal ions that showed protein interaction with Zn(2+) ions but not with Mn(2+) ions. Thus, we demonstrate that microcantilever bending can be used to discriminate between metal ions that bind and do not bind to AgNt84-6 protein in real time.

Biosensing Techniques↗

Detection of CrO4(2-) using a hydrogel swelling microcantilever sensor.

Hydrogels containing various mounts of tetraalkylammonium salts were used to modify microcantilevers for measurements of the concentration of CrO4(2-) in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various CrO4(2-) concentrations as a result of swelling or shrinking of the hydrogels. The microcantilever deflection as a function of the concentration of CrO4(2-) ions is nearly linear in most concentration ranges. It was found that a concentration of 10(-11) M CrO4(2-) can be detected using this technology in a fluid cell. Other ions, such as Br-, HPO4(2-), and NO3-, have minimal effect on the deflection of this cantilever. The anions SO4(2-) and CO3(2-) could interfere with the CrO4(2-) detection, but only at high concentrations (> 10(-5) M). Such hydrogel-coated microcantilevers could potentially be used to prepare microcantilever-based chemical and biological sensors when molecular recognition agents are immobilized in the hydrogel.

Journal Article↗

Size-correlated spectroscopy and imaging of rare-earth-doped nanocrystals.

Isolated europium-doped metal-oxide nanoparticles were probed by size-correlated high-numerical-aperture (far-field) imaging techniques. A modified Digital Instruments Bioscope atomic force microscope mounted upon a Nikon TE300 inverted microscope was used to interrogate (dry) particles ranging in size from 2 to 150 nm on the surface of a glass or quartz coverslip. These experiments revealed several interesting features of doped-nanoparticle luminescence such as Poissonian occupation statistics, size-dependent luminescence efficiency enhancement for particle sizes of <10 nm, and correlation of interesting transient behavior at particle sizes of <5 nm.

Journal Article↗

In situ detection of calcium ions with chemically modified microcantilevers.

We report a novel technique of micromechanical detection of trace amounts of calcium ions by using microcantilevers modified with ion-selective self-assembled monolayers (SAMs). The SAM-modified microcantilevers undergo bending due to selective adsorption of calcium ions. Experiments conducted under flow conditions show that the modified cantilevers respond sensitively to calcium ions (Ca(2+)); a Ca(2+) concentration of 10(-9) M can be detected with this technique. Other cations, such as Na(+) and K(+), do not have any effect on the deflection of these cantilevers. We demonstrate two different kinds of SAMs having selectivity for calcium ions.

Adsorption↗

Effects of temperature and pressure on microcantilever resonance response.

The variation in resonance response of microcantilevers was investigated as a function of pressure (10(-2)-10(6)Pa) and temperature (290-390K) in atmospheres of helium (He) and dry nitrogen (N(2)). Our results for a silicon cantilever under vacuum show that the frequency varies in direct proportion to the temperature. The linear response is explained by the decrease in Young's modulus with increasing the temperature. However, when the cantilever is bimaterial, the response is nonlinear due to differential thermal expansion. Resonance response as a function of pressure shows three different regions, which correspond to molecular flow regime, transition regime, and viscous regime. The deflection in flow transition regime resulting from thermal variation has minimal effect on frequency. The frequency variation of the cantilever is caused mainly by changes in the mean free path of gas molecules.

Journal Article↗

Covalent attachment of gold nanoparticles to DNA templates.

Functionalized gold nanoparticles have been covalently bound to internal, modified sites on double-stranded DNA. Gold nanoparticles coated with mercaptosuccinic acid or thioctic acid were bound to amino-modified thymine bases on double-stranded DNA. Visible absorption spectra, gel electrophoresis, and atomic force microscopy were used to analyze the products. Thiol groups were added to one end of the gold/nanoparticle product, which was then attached to a gold surface. This method has the potential to allow controlled placement of particles with subnanometer precision and to allow attachment of the product to fixed contacts for nanodevice fabrication.

Binding Sites↗