PubMed Health⌕ Search

Biomedical subjects

Thomas Welsch

Publications and source records attributed to Thomas Welsch.

4 recordsLinked to original sources

(Micellar) electrokinetic chromatography: an interesting solution for the liquid phase separation dilemma.

High-performance liquid chromatography (HPLC) is a well-established method in modern analysis. The method is simple, very robust and is applicable to the majority of components to be analyzed in contrast to gas chromatography. Low efficiency and small peak capacity are sore points of HPLC when complex mixtures have to be separated. The reason for this dilemma is the small diffusion coefficient of the analytes in the liquid mobile phase compared to a gaseous phase. This review, complemented by exemplary calculated data and some latest results of our own research, illustrates the dilemma of liquid phase chromatography to achieve high efficiencies under reasonable conditions. It is shown that (micellar) electrokinetic chromatography, offering fast and efficient separations, is a very promising solution for this dilemma. Additional features of this method are possibilities of on-line analyte concentration, coupling to mass spectrometry and the easy change of selectivities by applying various separation additives. The pros and cons of electrokinetic chromatography are pointed out and some application examples are given.

Chromatography, Micellar Electrokinetic Capillary↗

Automated microgradient system for capillary electrochromatography.

A microprocessor controlled gradient elution system suitable for capillary electrochromatography has been developed and tested. It is based on a liquid handling device described previously which is capable of liquid transport with both low and high fluid dispersion. The low dispersion region formed by stainless steel needle 250 microm I.D. serves for sample injection, while the high dispersion region, created by steep extension of tube diameter, is used for continuous mobile phase gradient generation. A homologous series of seven alkylphenones was electrochromatographically separated on a monolithic polyacrylic column under gradient conditions. An S-shaped acetonitrile gradient (30-70%) was applied. A high reproducibility of retention times (RSD about 0.1%) was obtained, indicating accuracy of automated gradient operations.

Automation↗

Improvement of the long-term stability of polyimide-coated fused-silica capillaries used in capillary electrophoresis and capillary electrochromatography.

Swelling of the polyimide coating of fused-silica capillaries in acetonitrile-containing buffers was found to be the reason for several problems in capillary electrophoresis (CE) and capillary electrochromatography (CEC). Scanning electron microscopy photographs of the ends of raw fused-silica tubing showed that the coating becomes soft and increases its volume after longer contact with such buffers. As a consequence, separation efficiency can deteriorate, the capillary ends can clog or break off. To prevent swelling of the polyimide coating, fused-silica capillaries used in CE or CEC were heated at 300 degrees C for a longer period of time which improved their long-term stability in comparison to raw fused-silica tubing.

Chromatography, Micellar Electrokinetic Capillary↗

Study of flow profile distortions and efficiency in counter pressure moderated partial filling micellar electrokinetic chromatography in relation to the relative buffer zone lengths.

The influence of the relative buffer zone lengths on the efficiency was investigated in partial filling micellar electrokinetic chromatography using sodium dodecyl sulfate as separation additive. Varying relative zone lengths were obtained by applying identical initial separation zone lengths but different total lengths of the capillaries. Plate numbers of a homologous series of omega-phenylalcohols were measured to indicate the effect of both a changing relative zone length during the run and a counter pressure applied on the cathodic buffer reservoir. The magnitude and the course of these plate numbers are discussed on the basis of models for flow profile superposition and flow profile deformation which are caused by an intersegmental pressure arising at the boundary between the two buffer zones with different electroosmotic flow velocities. Calculation of the intersegmental pressure and of the resulting laminar flow components in the buffer zones on the basis of some equations for electroosmotic and hydrodynamic flow supported the interpretation that a long background buffer zone should be avoided

Buffers↗