PubMed Health⌕ Search

Biomedical subjects

Thomas Wilhein

Publications and source records attributed to Thomas Wilhein.

3 recordsLinked to original sources

Condenser for Koehler-like illumination in transmission x-ray microscopes at undulator sources.

We report on a novel condenser for full-field transmission x-ray microscopes that use synchrotron radiation from an undulator source. The condenser produces a Koehler-like homogeneous intensity distribution in the sample plane and eliminates object illumination problems connected with the high degree of spatial coherence in an undulator beam. The optic consists of a large number of small linear diffraction gratings and is therefore relatively easy to manufacture. First imaging experiments with a prototype condenser were successfully performed with the Twinmic x-ray microscope at the Elettra synchrotron facility in Italy.

Journal Article↗

Single-optical-element soft-x-ray interferometry with a laser-plasma x-ray source.

We report on a compact interferometer for the water-window soft-x-ray range that is suitable for operation with laser-plasma sources. The interferometer consists of a single diffractive optical element that focuses impinging x rays to two focal spots. The light from these two secondary sources forms the interference pattern. The interferometer was operated with a liquid-nitrogen jet laser-plasma source at lambda=2.88 nm. Scalar wave-field propagation was used to simulate the interference pattern, showing good correspondence between theoretical and experimental results. The diffractive optical element can simultaneously be used as an imaging optic, and we demonstrate soft-x-ray microscopy with interferometric contrast enhancement of a phase object.

Journal Article↗

Differential interference contrast x-ray microscopy with twin zone plates.

X-ray imaging in differential interference contrast (DIC) with submicrometer optical resolution was performed by using a twin zone plate (TZP) setup generating focal spots closely spaced within the TZP spatial resolution of 160 nm. Optical path differences introduced by the sample are recorded by a CCD camera in a standard full-field imaging and by an aperture photodiode in a standard scanning transmission x-ray microscope. Applying this x-ray DIC technique, we demonstrate for both the full-field imaging and scanning x-ray microscope methods a drastic increase in image contrast (approximately 20x) for a low-absorbing specimen, similar to the Nomarski DIC method for visible-light microscopy.

Journal Article↗