32-element receiver-coil array for cardiac imaging.

A lightweight 32-element MRI receiver-coil array was designed and built for cardiac imaging. It comprises an anterior array of 21 copper rings (75 mm diameter) and a posterior array of 11 rings (107 mm diameter) that are arranged in hexagonal lattices so as to decouple nearest neighbors, and curved around the left side of the torso. Imaging experiments on phantoms and human volunteers show that it yields superior performance relative to an eight-element cardiac array as well as a 32-element whole-torso array for both traditional nonaccelerated cardiac imaging and 3D parallel imaging with acceleration factors as high as 16.

Algorithms↗

Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system.

Coronary MR angiography (CMRA) is generally confined to the acquisition of multiple targeted slabs with coverage dictated by the competing constraints of signal-to-noise ratio (SNR), physiological motion, and scan time. This work addresses these obstacles by demonstrating the technical feasibility of using a 32-channel coil array and receiver system for highly accelerated volumetric breath-hold CMRA. The use of the 32-element array in unaccelerated CMRA studies provided a baseline SNR increase of as much as 40% over conventional cardiac-optimized phased array coils, which resulted in substantially enhanced image quality and improved delineation of the coronary arteries. Modest accelerations were used to reduce breath-hold durations for tailored coverage of the coronary arteries using targeted multi-oblique slabs to as little as 10 s. Finally, high net accelerations were combined with the SNR advantages of a 3D steady-state free precession (SSFP) technique to achieve previously unattainable comprehensive volumetric coverage of the coronary arteries in a single breath-hold. The merits and limitations of this simplified volumetric imaging approach are discussed and its implications for coronary MRA are considered.

Coronary Angiography↗

Parallel imaging in cardiovascular MRI: methods and applications.

Cardiovascular MR imaging (CVMR) has become a valuable modality for the non-invasive detection and characterization of cardiovascular diseases. CVMR requires high imaging speed and efficiency, which is fundamentally limited in conventional cardiovascular MRI studies. With the introduction of parallel imaging, alternative means for increasing acquisition speed beyond these limits have become available. In parallel imaging some image data are acquired simultaneously, using RF detector coil sensitivities to encode simultaneous spatial information that complements the information gleaned from sequential application of magnetic field gradients. The resulting improvements in imaging speed can be used in various ways, including shortening long examinations, improving spatial resolution and/or anatomic coverage, improving temporal resolution, enhancing image quality, overcoming physiological constraints, detecting and correcting for physiologic motion, and streamlining work flow. Examples of each of these strategies will be provided in this review. First, basic principles and key concepts of parallel MR are described. Second, practical considerations such as coil array design, coil sensitivity calibrations, customized pulse sequences and tailored imaging parameters are outlined. Next, cardiovascular applications of parallel MR are reviewed, ranging from cardiac anatomical and functional assessment to myocardial perfusion and viability to MR angiography of the coronary arteries and the large vessels. Finally, current trends and future directions in parallel CVMR are considered.

Algorithms↗

Comprehensive cardiac magnetic resonance imaging at 3.0 Tesla: feasibility and implications for clinical applications.

OBJECTIVE: The objective of this study was to examine the applicability of high magnetic field strengths for comprehensive functional and structural cardiac magnetic resonance imaging (MRI). SUBJECTS AND METHODS: Eighteen subjects underwent comprehensive cardiac MRI at 1.5 T and 3.0 T. The following imaging techniques were implemented: double and triple inversion prepared FSE for anatomic imaging, 4 different sets of echocardiographic-gated CINE strategies for functional and flow imaging, inversion prepared gradient echo for delayed enhancement imaging, T1-weighted segmented EPI for perfusion imaging and 2-dimensional (2-D) spiral, and volumetric SSFP for coronary artery imaging. RESULTS: : Use of 3 Tesla as opposed to 1.5 Tesla provided substantial baseline signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) improvements for anatomic (T1-weighted double IR: DeltaSNR = 29%, DeltaCNR = 20%, T2-weighted double IR: DeltaSNR = 39%, DeltaCNR = 33%, triple IR: DeltaSNR = 74%, DeltaCNR = 60%), functional (conventional CINE: DeltaSNR = 123%, DeltaCNR = 74%, accelerated CINE: DeltaSNR = 161%, DeltaCNR = 86%), myocardial tagging (DeltaSNRsystole = 54%, DeltaCNRsystole = 176%), phase contrast flow measurements (DeltaSNR = 79%), viability (DeltaSNR = 48%, DeltaCNR = 40%), perfusion (DeltaSNR = 109%, DeltaCNR = 87%), and breathhold coronary imaging (2-D spiral: DeltaSNRRCA = 54%, DeltaCNRRCA = 69%, 3-D SSFP: DeltaSNRRCA = 60%, DeltaCNRRCA = 126%), but also revealed image quality issues, which were successfully tackled by adiabatic radiofrequency pulses and parallel imaging. CONCLUSIONS: Cardiac MRI at 3.0 T is feasible for the comprehensive assessment of cardiac morphology and function, although SAR limitations and susceptibility effects remain a concern. The need for speed together with the SNR benefit at 3.0 T will motivate further advances in routine cardiac MRI while providing an image-quality advantage over imaging at 1.5 Tesla.

Adult↗

Blood oxygen level-dependent MRI of tissue oxygenation: relation to endothelium-dependent and endothelium-independent blood flow changes.

OBJECTIVES: The contribution of endothelial function to tissue oxygenation is not well understood. Muscle blood oxygen level-dependent MRI (BOLD MRI) provides data largely dependent on hemoglobin (Hb) oxygenation. We used BOLD MRI to assess endothelium-dependent signal intensity (SI) changes. METHODS AND RESULTS: We investigated mean BOLD SI changes in the forearm musculature using a gradient-echo technique at 1.5 T in 9 healthy subjects who underwent a protocol of repeated acetylcholine infusions at 2 different doses (16 and 64 microg/min) and N(G)-monomethyl-L-arginine (L-NMMA; 5 mg/min) into the brachial artery. Sodium nitroprusside was used as a control substance. For additional correlation with standard methods, the same protocol was repeated, and forearm blood flow was measured by strain gauge plethysmography. We obtained a significant increase in BOLD SI during acetylcholine infusion (64 microg/min) and a significant decrease for L-NMMA infusion (P<0.005 for both). BOLD SI showed a different kinetic signal than did blood flow, particularly after intermittent ischemia and at high flow rates. CONCLUSIONS: In standard endothelial function tests, BOLD MRI detects a dissociation of tissue Hb oxygenation from blood flow. BOLD MRI may be a useful adjunct in assessing endothelial function.

Acetylcholine↗

Influence of high magnetic field strengths and parallel acquisition strategies on image quality in cardiac 2D CINE magnetic resonance imaging: comparison of 1.5 T vs. 3.0 T.

The aim of this paper is to examine signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image quality of cardiac CINE imaging at 1.5 T and 3.0 T. Twenty volunteers underwent cardiac magnetic resonance imaging (MRI) examinations using a 1.5-T and a 3.0-T scanner. Three different sets of breath-held, electrocardiogram-gated (ECG) CINE imaging techniques were employed, including: (1) unaccelerated SSFP (steady state free precession), (2) accelerated SSFP imaging and (3) gradient-echo-based myocardial tagging. Two-dimensional CINE SSFP at 3.0 T revealed an SNR improvement of 103% and a CNR increase of 19% as compared to the results obtained at 1.5 T. The SNR reduction in accelerated 2D CINE SSFP imaging was larger at 1.5 T (37%) compared to 3.0 T (26%). The mean SNR and CNR increase at 3.0 T obtained for the tagging sequence was 88% and 187%, respectively. At 3.0 T, the duration of the saturation bands persisted throughout the entire cardiac cycle. For comparison, the saturation bands were significantly diminished at 1.5 T during end-diastole. For 2D CINE SSFP imaging, no significant difference in the left ventricular volumetry and in the overall image quality was obtained. For myocardial tagging, image quality was significantly improved at 3.0 T. The SNR reduction in accelerated SSFP imaging was overcompensated by the increase in the baseline SNR at 3.0 T and did not result in any image quality degradation. For cardiac tagging techniques, 3.0 T was highly beneficial, which holds the promise to improve its diagnostic value.

Adult↗

Short breath-hold, volumetric coronary MR angiography employing steady-state free precession in conjunction with parallel imaging.

An ECG-gated, 3D steady-state free precession (SSFP) technique in conjunction with sensitivity encoding (SENSE)-based parallel imaging was implemented for short breath-hold, volumetric coronary MR angiograpy (CMRA). Two parallel imaging acquisition strategies (employing 1 R-R and 2 R-R intervals, respectively) were developed to achieve 1) very short breath-hold times (12 s for a heart rate of 60 bpm), and 2) small acquisition windows to minimize sensitivity to physiologic motion. Both strategies were examined in CMRA applications over a range of heart rates. A four-point scale blinded reading (with 4 indicating the most desirable features) revealed substantial image quality improvements for the accelerated data as compared to the nonaccelerated approach. The 1 R-R interval scheme yielded an image score of 3.39 +/- 0.60, and was found to be particularly suitable for low heart rates (P = 0.0008). The 2 R-R interval strategy yielded an image score of 3.35 +/- 0.64, and was more appropriate for higher heart rates (P = 0.03). The results demonstrate that 3D SSFP combined with parallel imaging is a versatile method for short breath-hold CMRA while maintaining high spatial resolution. This strategy permits imaging of the major coronary artery distributions in two to three breath-holds using targeted slabs, and offers the potential for single breath-hold, large-volume CMRA.

Adult↗

Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

RATIONALE AND OBJECTIVES: Many clinical applications of Magnetic Resonance Imaging are constrained by basic limits on imaging speed. Parallel MRI relaxes these limits by using the sensitivity patterns of arrays of radiofrequency receiver coils to encode spatial information in a manner complementary to traditional encoding with magnetic field gradients. Until now, parallel MRI has been used to achieve modest improvements in imaging speed; order-of-magnitude improvements have been elusive given fundamental losses in signal-to-noise ratio. The goal of this work was to demonstrate that, with appropriate hardware and careful SNR management, rapid volumetric imaging at high accelerations is in fact feasible. MATERIALS AND METHODS: Contrast-enhanced MRI with an axial 3D spoiled gradient echo imaging sequence was performed in healthy adult subjects using a 32-element RF coil array and a prototype 32-channel MR imaging system. Large imaging volumes were prescribed, in place of traditional limited slabs targeted only to suspect regions. RESULTS: As much as 16-fold net accelerations of imaging were achieved repeatably using this approach. The use of large 3D volumes allowed comprehensive anatomical coverage at clinically useful spatial and/or temporal resolution. The need for careful, time-consuming, and subject-specific scan prescription was also eliminated. CONCLUSION: The highly parallel imaging approach presented here allows previously inaccessible volumetric coverage for time-sensitive MRI examinations such as contrast-enhanced MRA, and simultaneously provides a substantially simplified imaging paradigm. The resulting capability for rapid volumetric imaging promises to combine the strengths of MRI with some of the advantages of alternative imaging modalities such as multidetector CT.

Adult↗

A feasibility study of contrast enhancement of acute myocardial infarction in multislice computed tomography: comparison with magnetic resonance imaging and gross morphology in pigs.

INTRODUCTION: Late enhancement magnetic resonance imaging (MRI) of myocardial infarction (MI) is clinically established. There are no reports on MI assessment using state-of-the-art multislice CT technology. For this reason, animal experiments were conducted to examine the applicability of contrast-enhanced ECG-gated multislice computed tomography (MSCT) for the detection of acute MI. The results were correlated with MRI and postmortem tissue staining. MATERIAL AND METHODS: Acute MI was induced in 14 pigs by balloon occlusion of the LAD. In 8 animals, the LAD was reperfused after 45 minutes. In 6 animals, the LAD was permanently blocked. MR imaging was performed 15 minutes after the administration of 0.2 mmol Gd-DTPA/kg/bodyweight. Subsequently, 16-slice MSCT was performed at various timepoints after injecting 120 mL of iodinated contrast medium. 2,3,5-Triphenyltetrazolin-chloride (TTC) staining was acquired for all hearts investigated. Correlation analysis was applied to compare the area of MI derived from MRI, MSCT, and TTC. The reperfused infarcts were compared with the nonreperfused infarcts using an unpaired t test. RESULTS: : Mean infarct area as measured by TTC staining was 18.3% +/- 7.8% of the left ventricular area. Good correlation of the spatial extent of the infarcted area was found for TTC and MRI as well as for TTC and MSCT data obtained 5 minutes postcontrast injection. MSCT imaging demonstrated a significant difference in density (P < 0.001) between nonreperfused (47.0 +/- 6.6 HU) and reperfused (116.4 +/- 19.8 HU) infarction. CONCLUSION: In our pilot study, contrast-enhanced MSCT was feasible to assess myocardial viability in pigs. MSCT also affords differentiation of nonreperfused and reperfused acute MI. MI sizes derived from MSCT imaging correlate well to those obtained with MRI and TTC.

Animals↗

Highly parallel volumetric imaging with a 32-element RF coil array.

The improvement of MRI speed with parallel acquisition is ultimately an SNR-limited process. To offset acquisition- and reconstruction-related SNR losses, practical parallel imaging at high accelerations should include the use of a many-element array with a high intrinsic signal-to-noise ratio (SNR) and spatial-encoding capability, and an advantageous imaging paradigm. We present a 32-element receive-coil array and a volumetric paradigm that address the SNR challenge at high accelerations by maximally exploiting multidimensional acceleration in conjunction with noise averaging. Geometric details beyond an initial design concept for the array were determined with the guidance of simulations. Imaging with the support of 32-channel data acquisition systems produced in vivo results with up to 16-fold acceleration, including images from rapid abdominal and MRA studies.

Equipment Design↗

Blood oxygen level-dependent magnetic resonance imaging in patients with stress-induced angina.

BACKGROUND: Blood oxygen level-dependent (BOLD) MRI reflects tissue oxygenation and may be useful for the detection of myocardial ischemia in patients with suspected coronary artery disease. METHODS AND RESULTS: We studied 25 patients with stress-induced angina using a T2*-sensitive echo planar imaging sequence before and during adenosine in a single-slice approach. BOLD-MRI results were compared with quantitative angiography and adenosine thallium single-photon emission computed tomography (SPECT). Although image quality was variable because of artifacts, no data were excluded from the analysis. During adenosine, a mean signal intensity decrease was observed for myocardial segments related to coronary stenoses >75%. On average, a nonsignificant increase was observed in the other segments. The angiographically determined stenosis was correlated with BOLD-MRI results. Including all segments and using BOLD-MRI signal intensity increase cutoff value of 1.2%, BOLD-MRI had a sensitivity of 88% and a specificity of 47% to correctly classify severe stenoses. Adenosine thallium SPECT data from distal segments of the same coronary territory were also correlated with BOLD-MRI. However, variability was substantial. CONCLUSIONS: In patients with stress-induced angina, adenosine BOLD-MRI detects myocardial ischemia in myocardial segments related to severe coronary stenoses. Its potential will increase with additional improvement of spatial coverage and image quality.

Adenosine↗

T1 mapping in patients with acute myocardial infarction.

Pixel-by-pixel calculation of T1 values (T1 mapping) has been used in different tissues to focus on T1 changes in a quantitative fashion. The aim of this study was to establish T1 mapping of human myocardium on a 1.5 Tesla system and to examine its diagnostic potential in patients with acute myocardial infarction (AMI). 8 patients with reperfused AMI (day 3 +/- 1) underwent multi-breath-hold MRI in a 1.5 Tesla system. Sets of five images with varying T1 weighting were acquired prior to and after the administration of contrast agent to generate images from calculated T1 values (T1 mapping). Prior to the contrast agent administration, all patients showed T1 prolongation in the area of infarction, which was identified in separate measurements using the delayed enhancement approach. Compared to noninfarcted areas, T1 values in the infarcted areas were increased by 18 +/- 7% (SE, p < 0.05). The spatial extent of the area of T1 prolongation was larger than that of the hyper-enhanced areas in conventional contrast-enhanced images. T1 maps obtained after the application of Gadolinium-DTPA revealed a T1 reduction of 27 +/- 4% in infarcted tissue compared to noninfarcted areas (p < 0.05). The areas showing T1 reduction were in agreement with the hyper-enhanced regions in conventional T1-weighted images. T1 mapping visualizes changes in the longitudinal relaxation time induced by AMI. T1 mapping can detect myocardial necrosis without the use of contrast media. Information that can be extracted from a combination of pre- and postcontrast T1 maps exceeds that from conventional contrast studies.

Adult↗