PubMed Health⌕ Search

Biomedical subjects

Thorsten Lewalter

Publications and source records attributed to Thorsten Lewalter.

At least 19 recordsLinked to original sources

Cardiac morphogenetic defects and conduction abnormalities in mice homozygously deficient for connexin40 and heterozygously deficient for connexin45.

Connexin40 (Cx40) and connexin45 (Cx45) are involved in both cardiac morphogenesis and propagation of electrical activity. We found that Cx40/Cx45 double deficiency (Cx40(-/-)/Cx45(+/-)) causes a variety of cardiac defects leading to high mortality during embryonic development and at birth. The majority of Cx40(-/-)/Cx45(+/-) embryos and postnatal mice suffered from atrioventricular septal defects. Additional cardiac abnormalities, e.g., ventricular septal defects and abnormal myocardial arrangement, occurred at lower abundance. Electrocardiograms of Cx40(-/-)/Cx45(+/+) and Cx40(-/-)/Cx45(+/-) mice revealed prolongation of P-wave, PQ interval and QRS duration compared to controls. Interestingly, in Cx40(-/-)/Cx45(+/-) mice, PQ interval and QRS duration were significantly prolonged compared to Cx40(-/-)/Cx45(+/+) mice. We conclude that the gap junctional proteins Cx40 and Cx45 have overlapping and partially compensatory functions with regard to heart morphogenesis and cardiac conduction. Cx45 might be one of the genetic modifiers that can cause variations in the phenotype of connexin40-deficient animals. Our findings may be particularly relevant for understanding molecular factors contributing to human congenital cardiac diseases.

Animals↗

[German Competence Network on Atrial Fibrillation (AFNET). A nationwide cooperation for better research and patient care].

The Atrial Fibrillation Competence Network is an interdisciplinary national research network funded by the Federal Ministry of Education and Research (BMBF). The aim of the network--founded in 2003--is to improve the treatment of atrial fibrillation, the most common clinically important arrhythmia of the heart. A decentralized patient registry has been established. This registry, which comprises the manifestation, diagnostics and therapy of atrial fibrillation in Germany, is being used as a data basis for epidemiologic clinical studies. Epidemiologic projects are being conducted to study, e.g., the prevalence of atrial fibrillation as well as the occurrence of complications. Four multicenter clinical trials have been started to optimize pharmacological treatments (ANTIPAF trial, Flec-SL trial), preventive pacing (BACE-PACE trial) and catheter-based ablation (GAP-AF trial). Other clinical projects are being conducted to study the risk of neurologic complications and to develop new diagnostic imaging techniques. Experimental basic research projects are focusing on different aspects of atrial remodeling in order to find out in which way the molecular mechanisms can be manipulated by new methods of treatment. First results are presented.

Atrial Fibrillation↗

Pro-arrhythmic effects of amiodarone and concomitant rate-control medication.

AIMS: Amiodarone is one of the most efficient and safe antiarrhythmic drugs in the treatment of atrial fibrillation (AF). Although pro-arrhythmic effects of amiodarone therapy are rare, the aim of the present study was to identify clinical constellations which may lead to amiodarone-associated pro-arrhythmia. METHODS AND RESULTS: Sixty-three consecutive patients (pts) (49 males; 64+/-10.3 years; 35 with coronary heart disease, 17 with lone AF) were retrospectively included in this study. All received an oral (92.1%) or i.v. (7.9%) loading dose of amiodarone for the treatment of AF. Cardiac diseases, concomitant medical treatment, and incidence of pro-arrhythmic effects were analysed. Three pts (4.8% of the total population) developed a clinical relevant, polymorphic ventricular tachyarrhythmia, 3-48 h after initiation of amiodarone loading. Coronary heart disease was present in all of these pts, and in two of them left ventricular ejection fraction was severely reduced. The mean QTc in these pts was only slightly prolonged; mean heart rate was significantly decreased compared with the total study population (61.0+/-7.5 vs. 74.5+/-24.1 bpm; P < or = 0.05). In all pts with pro-arrhythmia, amiodarone (two pts i.v., one patient oral) was initiated during concomitant beta-blocker/digitalis therapy. Twenty-five per cent of the patients receiving this 'triple' therapy developed ventricular arrhythmia. CONCLUSION: The present study implies that initiation of amiodarone therapy in pts with structural heart disease and AF that are concomitantly treated with beta-blockers and digitalis may have an increased risk of amiodarone-associated pro-arrhythmia.

Adult↗

New insights into the initiation of atrial fibrillation: a detailed intraindividual and interindividual analysis of the spontaneous onset of atrial fibrillation using new diagnostic pacemaker features.

BACKGROUND: This study investigated onset scenarios of atrial fibrillation (AF), the first phase of the Atrial Fibrillation Therapy (AFT) trial, to determine potential arrhythmogenic triggers as targets for atrial pacing algorithms that have been proposed for prevention of AF. METHODS AND RESULTS: Ninety-eight patients (58 men; age 65+/-11 years) with recurrent, symptomatic, drug-refractory AF and a conventional pacemaker indication in 31 of 98 received a dual-chamber pacemaker. Using novel diagnostic pacemaker features AF onset scenarios were prospectively evaluated in 612 AF episodes during a 2-month monitoring period, with atrial pacing limited to 40 bpm. The most common onset scenario was premature atrial complexes (PACs) before AF (48% onsets per patient), followed by bradycardia (33%), sudden onset (17%), and tachycardia (0%). Combinations of onset scenarios were frequent (median 2 different scenarios per patient). A main study finding was the significance of repetitive AF, with 33% of onsets per patient being initiated within 5 minutes of a previous AF episode. Sudden onsets were more frequent among patients with than without repetitive AF (24% versus 0% onsets per patient, P=0.011), whereas the proportion of PACs before AF was not statistically different (50% versus 37%, P=0.52); however, patients with repetitive AF had more PACs per hour (72 versus 29, P=0.023) and a higher number of AF episodes per day (17 versus 0, P=0.001) and were more likely to have at least 1 PAC-related onset (90% versus 53%, P<0.0001). CONCLUSIONS: Novel diagnostic pacemaker features allowed a detailed individual analysis of rate and rhythm changes before AF and thus uncovered a substantial intraindividual and interindividual variability of AF onset scenarios.

Aged↗

Connexin30.2 containing gap junction channels decelerate impulse propagation through the atrioventricular node.

In the mammalian heart, gap junction channels between electrically coupled cardiomyocytes are necessary for impulse propagation and coordinated contraction of atria and ventricles. Recently, mouse connexin30.2 (Cx30.2) was shown to be expressed in the cardiac conduction system, predominantly in sinoatrial and atrioventricular (AV) nodes. The corresponding gap junctional channels expressed in HeLa cells exhibit the lowest unitary conductance (9 pS) of all connexin channels. Here we report that Cx30.2 slows down the propagation of excitation through the AV node. Mice expressing a LacZ reporter gene instead of the Cx30.2 coding region (Cx30.2(LacZ/LacZ)) exhibit a PQ interval that is approximately 25% shorter than in WT littermates. By recording atrial, His, and ventricular signals with intracardiac electrodes, we show that this decrease is attributed to significantly accelerated conduction above the His bundle (atrial-His interval: 27.9 +/- 5.1 ms in Cx30.2(LacZ/LacZ) versus 37.1 +/- 4.1 ms in Cx30.2(+/+) mice), whereas HV conduction is unaltered. Atrial stimulation revealed an elevated AV-nodal conduction capacity and faster ventricular response rates during induced episodes of atrial fibrillation in Cx30.2(LacZ/LacZ) mice. Our results show that Cx30.2 contributes to the slowdown of impulse propagation in the AV node and additionally limits the maximum number of beats conducted from atria to ventricles. Thus, it is likely to be involved in coordination of atrial and ventricular contraction and to fulfill a protective role toward pathophysiological states such as atrial tachyarrhythmias (e.g., atrial fibrillation) by preventing rapid conduction to the ventricles potentially associated with hemodynamic deterioration.

Animals↗

Identification of "substrate fibrillators" and "trigger fibrillators" by pacemaker diagnostics.

BACKGROUND: The population of patients likely to respond to selected pacing algorithms for maintenance of sinus rhythm is unknown. OBJECTIVES: The purpose of this study was to identify patients with specific onset patterns of paroxysmal atrial fibrillation (AF). METHODS: Dual-chamber pacemakers with advanced diagnostic functions were implanted in 112 patients with conventional indications for antibradycardia pacing and a history of paroxysmal AF. Pacemaker diagnostic data were analyzed after 97.5 +/- 40.9 days. According to the frequency of premature atrial contractions (PACs) during the 5 minutes before AF onset, patients were assigned to one of three groups: group A (high PAC activity), group B (moderate PAC activity), or group C (low PAC activity). RESULTS: AF burden was lower in group A (4.6% +/- 2.4%) than group B (15.8% +/- 3.0%, P = .003) and group C (15.5% +/- 3.1%, P = .003). Fewer AF episodes occurred in group A (2.1 +/- 1.3 per day) than group B (3.8 +/- 1.2 per day, P = .006). Mean AF episode duration was shorter in group A (11.4 +/- 10.2 hours) than group C (41.4 +/- 27.5 hours, P = .03). CONCLUSION: The coincidence of low PAC activity before AF onset, high AF burden, and extended arrhythmia episode duration appears to be the consequence of a high atrial substrate factor. In these "substrate fibrillators," the efficacy of pacing algorithms for maintenance of sinus rhythm may be limited. In contrast, "trigger fibrillators" exhibiting low AF burden despite high PAC incidence may represent the target population for specific PAC-suppressing pacing algorithms.

Aged↗

Transient ST-segment-elevation during pulmonary vein ablation using circumferential coiled microelectrodes in a prospective multi-centre study.

AIMS: Paroxysmal atrial fibrillation (PAF) is predominantly triggered by focal ectopies located within the pulmonary veins (PV). The BITMAP Study (Breakthrough and Isolation Trial: Mapping and Ablation of Pulmonary Veins) investigated prospectively the safety and efficacy of a catheter design with circumferential mapping and ablation electrodes. We report the phenomenon of ST-segment-elevation during catheter placement in the left atrium (LA) and superior PVs in this multi-centre study. METHODS AND RESULTS: Forty-three patients (57+/-10 years) with PAF were included in this study. Radiofrequency catheter (RFC) ablation supported by the 4F REVELATION Helix microcatheter (Cardima Inc., Freemont, CA, USA) with eight distal-coiled microelectrodes for bipolar mapping and ablation. RFC was applied at the ostial region of PV (30 W, 45-50 degrees C) with a maximum of four RFC applications per electrode. In four of the 43 patients from three centres, we recorded the occurrence of ST-segment-elevation greater than 0.2 mV and accompanying left thoracic discomfort. The ECG changes and the symptoms started abruptly and lasted for 4.2+/-2.2 min. Pericardial effusion could instantaneously be excluded by echocardiography in all cases. Coronary angiograms were performed in three patients with the longest episodes; no thrombotic material or air emboli were present. The symptoms and the ECG changes resolved completely in all patients. CONCLUSION: The phenomenon of ST-segment-elevation during LA- and PV-mapping in patients with PAF may be a common occurrence. In this prospective multi-centre trial, we demonstrated the reversibility of this phenomenon; no cardiovascular or cerebral damage was reported during both the procedure and the follow-up. Although the mechanism is still unclear, vasospasm may contribute to this phenomenon because of autonomic dysregulation.

Adult↗

Persistence of iatrogenic atrial septal defect after pulmonary vein isolation--an underestimated risk?

BACKGROUND: According to present knowledge, pulmonary vein isolation (PVI) bears a low interventional risk and has a high feasibility. For completion of PVI, left atrial access is achieved via single or double transseptal puncture. We sought to determine the incidence and echocardiographic characteristics of persistent iatrogenic atrial septal defect (iASD) after PVI. Further objectives were to define clinical and periprocedural risk factors for the development of iASD. METHODS: Every patient admitted for PVI at our hospital was screened for eligibility for study participation. Exclusion criteria were inability for undergoing transesophageal echocardiography, preexisting atrial septal defect, open-heart surgery or another transseptal procedure during the follow-up period. Transesophageal echocardiography was performed before PVI and after 9 months. Interatrial shunt was characterized by echocardiographic parameters; right-to-left-shunting (RLS) was quantified by contrast echocardiography. RESULTS: Forty-two patients were included, 27 patients underwent PVI with single transseptal puncture and additional advancement of a second electrophysiologic catheter (group A) 15 patients underwent PVI with double transseptal puncture (group B). In 8 patients of group A, iASD persisted after the follow-up period, including 6 patients with distinct RLS. We saw no iASD in group B (P = .011, CI -0.79 to -0.11). Preprocedural pulmonary artery pressure was significantly higher in patients with iASD and accompanying RLS, compared with patients with iASD and no evidence of RLS (23.75 +/- 0.50 vs 17.59 +/- 5.82, P = .048, CI 0.048-12.27). CONCLUSION: This is the first study that demonstrates a high incidence of long-term persistent iatrogenic atrial septal defect with RLS after PVI. All interatrial shunts occurred after single transseptal puncture with passage of 2 electrophysiologic catheters into the left atrium. Increased preprocedural pulmonary artery pressure seems to promote the occurrence of RLS across iASD.

Adult↗

Strategy for safe performance of magnetic resonance imaging on a patient with implantable cardioverter defibrillator.

Clinically indicated magnetic resonance imaging (MRI) of the brain was safely performed at 1.5 T on a patient with an implantable cardioverter defibrillator (ICD). The ICD was reprogrammed to detection only, and imaging hardware and protocols were modified to minimize radiofrequency power deposition to the ICD system. The integrity of the ICD system was verified immediately post-MRI and after 6 weeks, including an ICD test with induction of ventricular fibrillation. This case demonstrates that in exceptional circumstances, in carefully selected patients, and using special precautions, an MRI exam of the brain may be possible in patients with ICDs.

Adult↗

Individualized selection of pacing algorithms for the prevention of recurrent atrial fibrillation: Results from the VIP registry.

OBJECTIVES: The VIP registry investigated the efficacy of preventive pacing algorithm selection in reducing atrial fibrillation (AF) burden. BACKGROUND: There are few data identifying which patients might benefit most from which preventive pacing algorithms. METHODS: Patients, with at least one documented AF episode and a conventional antibradycardia indication for pacemaker therapy, were enrolled. They received pacemakers with AF diagnostics and four preventive algorithms (Selection and PreventAF series, Vitatron). A 3-month Diagnostic Phase with conventional pacing identified a Substrate Group (>70% of AF episodes with <2 premature atrial contractions [PACs] before AF onset) and a Trigger Group (< or =70% of AF episodes with <2 PACs before AF onset). This was followed by a 3-month Therapeutic Phase where in the Trigger Group algorithms were enabled aimed at avoiding or preventing a PAC and in the Substrate Group continuous atrial overdrive pacing was enabled. RESULTS: One hundred and twenty-six patients were evaluated. In the Trigger Group (n = 73), there was a statistically significant 28% improvement in AF burden (median AF burden: 2.06 hours/day, Diagnostic Phase vs 1.49 hours/day, Therapy Phase; P = 0.03304 signed-rank test), and reduced PAC activity. There was no significant improvement in AF burden in the Substrate Group (median AF burden: 1.82 hours/day, Diagnostic Phase vs 2.38 hours/day, Therapy Phase; P = 0.12095 signed-rank test), and little change in PAC activity. CONCLUSIONS: We identified a subgroup of patients for whom the selection of appropriate pacing algorithms, based on individual diagnostic data, translated into a reduced AF burden. Trigger AF patients were more likely responders to preventive pacing algorithms as a result of PAC suppression.

Aged↗

"Torsade de pointes" in patients with structural heart disease and atrial fibrillation treated with amiodarone, beta-blockers, and digitalis.

Amiodarone is one of the most efficient and safe antiarrhythmic drugs in the treatment of atrial fibrillation (AF). Yet, though rare, proarrhythmic effects remain a clinical problem. We present three cases of amiodarone-associated "Torsade de pointes" tachycardia (Tdp) in patients treated concomitantly with heart rate controlling medication for AF. Amiodarone loading therapy was started for the treatment of tachyarrhythmic AF in all the three patients. All presented with a history of coronary heart disease, resulting in a severely reduced left ventricular ejection fraction in two patients. One received oral amiodarone loading, in the others, amiodarone was administered intravenously because of hemodynamically relevant AF episodes. Amiodarone therapy was combined with a heart rate controlling medication including a beta-blocking agent and digitalis in all the cases. All the subjects suffered from clinically relevant Tdp in the early run after initiation of amiodarone loading (max. 48 hours). The mean QTc in all patients before induction of Tdp was prolonged. The present case reports imply that amiodarone in combination with beta-blocker/digitalis therapy may be associated with an elevated proarrhythmic risk in selected patients with structural heart disease and AF.

Adrenergic beta-Antagonists↗

Paroxysmal atrial flutter caused by cardiac lymphoma.

Atrial flutter is a relatively frequent macro-reentrant tachycardia that can be caused by a variety of structural and functional atrial changes. Cardiac lymphoma is rare and usually carries a poor prognosis. It preferentially involves the right atrium. This report describes a patient with cardiac follicular B-cell lymphoma who developed paroxysmal atrial flutter. The large tumor mass created a macroscopic substrate for an area of slow conduction which is essential for atrial flutter. It also caused sinus arrest and intermittent obstruction of the tricuspid valve inlet.

Aged↗

Cerebral diffusion-weighted magnetic resonance imaging: a tool to monitor the thrombogenicity of left atrial catheter ablation.

INTRODUCTION: Cerebral embolism and stroke are feared complications of left atrial catheter ablation such as pulmonary vein (PV) ablation. In order to assess the thrombogenicity of left atrial catheter ablation, knowledge of both clinically evident as well as silent cerebral embolism is important. The aim of the current study was to examine the use of diffusion-weighted magnetic resonance imaging (DW-MRI) for detection of cerebral embolism, apparent as well as silent, caused by PV catheter ablation. METHODS AND RESULTS: Twenty consecutive patients without structural heart disease undergoing lasso catheter-guided ostial PV ablation using an irrigated-tip ablation catheter were studied. Cerebral MRI including DW single-shot spin echo echoplanar, turbo fluid attenuated inversion recovery, and T2-weighted turbo spin echo sequences were performed the day after the ablation procedure. Ten patients also underwent preprocedure cerebral MRI. All ablation procedures were performed without acute complications. A mean of 3.2 +/- 0.6 PVs were ablated per patient. No patient had neurological symptoms following the procedure. In 2 of 20 patients (10%), DW-MRI revealed new embolic lesions, which were located in the right periventricular white matter in one and in the left temporal lobe in the other patient. There was no statistically significant difference in age, history of hypertension, left atrial volume, and procedure duration between the 2 patients with and the 18 patients without cerebral embolism following AF ablation. CONCLUSION: This is the first study using highly sensitive DW-MRI of the brain to detect asymptomatic cerebral embolism after left atrial catheter ablation. Even small, clinically silent, embolic lesions can be demonstrated with this technique. DW-MRI can be used to monitor and compare the thrombogenicity of different AF ablation approaches.

Adult↗

Echocardiographic assessment of left ventricular mass in neonatal and adult mice: accuracy of different echocardiographic methods.

Echocardiography is an established method to estimate left-ventricular mass (LVM) in mice. Accuracy is determined by cardiac size and morphology and influenced by mathematical models. We investigated accuracy of three common algorithms in three early developmental stages. High-resolution echocardiography was performed in 35 C57/BL6-mice. Therefore, two-dimensional-guided M-mode echocardiography and parasternal short- and long-axis views in B-mode were obtained. LVM was assessed in vivo applying Penn (P), Area Length (AL), and Truncated Ellipsoid (TE) algorithms and validated with histomorphometry. Regression analysis of all mice showed fair estimation of LVM assessed with M-mode-based Penn algorithm (y = 0.6*x - 0.12, r: 0.71). In contrast two-dimensional assessment of LVM revealed close linear relationship with histomorphometry (y(AL)= 1.21*x - 12.1, r: 0.88, y(TE)= 1.38*x - 2.88, r: 0.86). Bias was lowest for LVM-AL at diastole underestimating 3.2%. In concordance with the summarized data, LVM-P revealed lower regression coefficients and significant underestimation in all three subgroups. Small hearts (<50 mg, n = 12) correlated best with LVM-AL at systole. Hearts of adolescent (50-75 mg, n = 13) and adult (75-100 mg, n = 10) mice revealed close linear relationship with LVM-AL and LVM-TE at diastole. Echocardiographic assessment of LVM is feasible in hearts weighting less than 50 mg and can be estimated best in systole. Hearts weighting more than 50 mg are estimated most accurately by means of LVM-AL at diastole.

Algorithms↗

[Cardiac pacing for the prevention of atrial fibrillation. A current review].

Several prospective randomized clinical trials have reported that atrial-based "physiological" pacing is associated with a lower incidence of paroxysmal and permanent atrial fibrillation than single-chamber ventricular pacing in patients with conventional pacemaker indication. Whether atrial pacing itself is antiarrhythmic remains still uncertain. By contrast, right ventricular pacing is considered to beget atrial fibrillation, even in preserved AV synchrony during dual-chamber pacing. A number of clinical trials investigated the impact of sitespecific atrial pacing and advanced atrial pacing algorithms on the secondary prevention of atrial fibrillation. Multisite pacing (dual-site right atrial or biatrial pacing) was demonstrated to add only minimal benefit for the prevention of atrial fibrillation. By contrast, in some studies septal pacing and specific atrial pacing algorithms were reported to reduce the recurrence of atrial fibrillation in selected patients. At present, however, it remains unclear how to identify these patients. In clinical practice, the effectiveness of specific atrial pacing algorithms and/or septal pacing has to be tested out in the individual case. These therapeutic options should be considered in patients with a conventional indication for antibradycardia pacing and, additionally, symptomatic atrial fibrillation.

Algorithms↗

Impact of age and basic heart rate on heart rate turbulence in healthy persons.

Postextrasystolic acceleration of heart rate (HR), known as HR turbulence (HRT) is attenuated in patients with coronary artery disease at increased risk of adverse events. The influence of age and basic HR on HRT have not been evaluated in a large cohort of persons. In 95 healthy individuals, HRT onset (TO) and slope (TS) were calculated from 24-hour ambulatory electrocardiograms, as well as the turbulence timing (TT). Gender specific differences in TO and TS were compared in simple, linear, weighted regression model. The influence of age and the basic HR preceding ventricular premature contractions on HRT were examined. We found that, in men and women, TO decreases as basic HR increases (P < 0.01). In contrast, in men, TS decreased as basic HR increases, whereas in women, basic HR influenced TS only slightly (P < 0.01). A multiple, linear regression model revealed a decrease in HRT with increasing age in men. In conclusion, physiological acceleration of the HR within the first 11 beats after premature ventricular complex (VPC) was observed in >75% of healthy individuals. An accelerating HR preceding the VPC influenced HRT in men. An increasing age was associated with a decrease in HRT in men and a decrease in TO in women. These results illustrate the importance of physiological modulations of HRT when used for risk stratification, especially in older populations.

Adult↗

Gold-tip electrodes--a new "deep lesion" technology for catheter ablation? In vitro comparison of a gold alloy versus platinum-iridium tip electrode ablation catheter.

Gold-tip electrodes. Radiofrequency (RF) catheter ablation is widely used to induce focal myocardial necrosis using the effect of resistive heating through high-frequency current delivery. It is current standard to limit the target tissue-electrode interface temperature to a maximum of 60-70 degrees C to avoid char formation. Gold (Au) exhibits a thermal conductivity of nearly four times greater than platinum (Pt-Ir) (3.17 W/cm Kelvin vs 0.716 W/cm Kelvin), it was therefore hypothesized that RF ablation using a gold electrode would create broader and deeper lesions as a result of a better heat conduction from the tissue-electrode interface and additional cooling of the gold electrode by "heat loss" to the intracardiac blood. Both mechanisms would allow applying more RF power to the tissue before the electrode-tissue interface temperature limit is reached. To test this hypothesis, we performed in vitro isolated liver and pig heart investigations comparing lesion depths of a new Au-alloy-tip electrode to standard Pt-Ir electrode material. Mean lesion depth in liver tissue for Pt-Ir was 4.33+/-0.45 mm (n=60) whereas Au electrode was able to achieve significantly deeper lesions (5.86+/-0.37 mm [n=60; P<0.001]). The mean power delivered using Pt-Ir was 6.95+/-2.41 W whereas Au tip electrode delivered 9.64+/-3.78 W indicating a statistically significant difference (P<0.05). In vitro pig heart tissue Au ablation (n=20) increased significantly the lesion depth (Au: 4.85+/-1.01 mm, Pt-Ir: 2.96+/-0.81 mm, n=20; P<0.001). Au tip electrode again applied significantly more power (P<0.001). Gold-tip electrode catheters were able to induce deeper lesions using RF ablation in vitro as compared to Pt-Ir tip electrode material. In liver and in pig heart tissue, the increase in lesion depth was associated with a significant increase in the average power applied with the gold electrode at the same level of electrode-tissue temperature as compared to platinum material.

Animals↗