Tianfu Yang

Publications and source records attributed to Tianfu Yang.

3 recordsLinked to original sources

[The biomechanical study of rotating-arm self-locking intramedullary nails in comminuted femoral shaft fractures].

This study was sought to compare and evaluate the biomechanical properities of rotating-arm self-locking intramedullary nails (RSIN) with domestic femoral intramedullary nail (DFIN) in communited femoral shaft fractures. A 2 cm midshaft defect was created on seven pairs of cadaver femur, and fixed with two kinds of intramedullary nails. Then the torsion, four-point bending and axial loading to failure were tested on these models. The load versus deformation curve was generated from the load recorded by the load cell and the deformation simultaneously recorded by the linear variable displacement transducer. The mean torsional stiffness of the femora fixed with RSIN was 0.98 Nm/degree, which was significantly less than that fixed with the similar nails reported in documents, and the mean value of bending stiffness of the femur fixed with DFIN was larger than that of the femur fixed with RBIN, but there was no significant statistic difference. For use in fracture models under compression load beyond 1200 N, the RBIN was more rigid than DFIN, which provided the biggest load. All the parameters of the test with nails were greater than that for femur fixed with nails. In conclusion, FBIN probably provides enough strength and rigidity for use in communited femoral shaft fractures.

Adult↗

[A preliminary clinical study on absorbable screws].

To evaluate the application of self-reinforced ploy-DL-lactide (SR-PDLLA) absorbable screws in the treatment of spongy bone and intra-articular fractures, the internal fixation with SR-PDLLA absorbable screw was performed on 58 cases,of which 25 were medial malleolus fractures, 14 condyle of humerus fractures, 9 tibial plateau fractures, 7 ulnar olecranon fractures, and 3 lateral malleolus fractures. Observations were made on the orthopaedic operation sites and overall conditions frequently and radiography was performed for periodic analysis. The results showed that SR-PDLLA absorbable screws were particularly effective and reliable, they had good biocompatibility in the treatment of spongy bone and intra-articular fractures and could be used safely in clinical practice.

Absorbable Implants↗

[Biomechanical study on rotating-arm self-locking intramedullary nail in the treatment of tibial shaft fracture].

We have designed a new kind of self-locking intramedullary nail for the treatment of unstable fracture of the middle and distal tibial shaft and have compared it with the interlocking nail by means of biomechanical experiments. The data could be used as a basis for clinical application. Fourteen formalin-fixed tibials of adults were made into unstable fracture models with a 2cm bone defect each. They were divided into 2 groups. Group 1 was fixed with self-locking intramedullary nail and group 2 was fixed by interlocking nail. All specimens were submitted to biomechanical test. The data were analysed by t test. The results showed there is no difference in anti-bending stiffness between the self-locking intramedullary nail and the interlocking nail. The anti-rotating and anti-compressing stiffness of interlocking nail is slightly better than that of self-locking intramedullary nail, but still the firmmess of the self-locking intramedullary nail in resisting rotation can meet the requirement of biological fixation. Its structure is reasonable, simple, practical, and it can resist certain harmful stress.