PubMed Health⌕ Search

Biomedical subjects

Tianlun Jiang

Publications and source records attributed to Tianlun Jiang.

3 recordsLinked to original sources

Rapid and simultaneous quantification of 4 urinary proteins by piezoelectric quartz crystal microbalance immunosensor array.

BACKGROUND: Urinary proteins are predictive and prognostic markers for diabetes nephropathy. Conventional methods for the quantification of urinary proteins, however, are time-consuming, and most require radioactive labeling. We designed a label-free piezoelectric quartz crystal microbalance (QCM) immunosensor array to simultaneously quantify 4 urinary proteins. METHODS: We constructed a 2 x 5 model piezoelectric immunosensor array fabricated with disposable quartz crystals for quantification of microalbumin, alpha1-microglobulin, beta2-microglobulin, and IgG in urine. We made calibration curves after immobilization of antibodies at an optimal concentration and then evaluated the performance characteristics of the immunosensor with a series of tests. In addition, we measured 124 urine samples with both QCM immunosensor array and immunonephelometry to assess the correlation between the 2 methods. RESULTS: With the QCM immunosensor array, we were able to quantify 4 urinary proteins within 15 min. This method had an analytical interval of 0.01-60 mg/L. The intraassay and interassay imprecisions (CVs) were <10%, and the relative recovery rates were 90.3%-109.1%. Nonspecificity of the immunosensor was insignificant (frequency shifts <20 Hz). ROC analyses indicated sensitivities were > or =95.8% and, specificities were > or =76.3%. Bland-Altman difference plots showed the immunosensor array to be highly comparable to immunonephelometry. CONCLUSIONS: The QCM system we designed has the advantages of being rapid, label free, and highly sensitive and thus can be a useful supplement to commercial assay methods in clinical chemistry.

Alpha-Globulins↗

Construction of a novel peptide nucleic acid piezoelectric gene sensor microarray detection system.

A novel 2 x 5 clamped style piezoelectric gene sensor microarray has been successfully constructed. Every crystal unit of the fabricated gene sensor can oscillate independently without interfering with each other. The bis-peptide nucleic acid (bis-PNA) probe, which can combine with target DNA or RNA sequences more effectively and specifically than a DNA probe, was designed and immobilized on the surface of the gene sensor microarray to substitute the conventional DNA probe for direct detection of the hepatitis B virus (HBV) genomic DNA. Detection conditions were then explored and optimized. Results showed that PBS buffer of pH 6.8, an ion concentration of 20 mmol/liter, and a probe concentration of 1.5 micromol/liter were optimal for the detection system. Under such optimized experimental conditions, the specificity of bis-PNA was proved much higher than that of DNA probe. The relationship between quantity of target and decrease of frequency showed a typical saturation curve when concentrations of target HBV DNA varied from 10 pg/liter to 100 microg/liter, and 10 microg/liter was the watershed, with a statistic linear regression equation of I gC = -2.7455 + 0.0691 deltaF and the correlating coefficient of 0.9923. Fortunately, this is exactly the most ordinary variant range of the HBV virus concentration in clinical hepatitis samples. So, a good technical platform is successfully constructed and it will be applied to detect HBV quantitatively in clinical samples.

Base Sequence↗

A novel piezoelectric quartz micro-array immunosensor based on self-assembled monolayer for determination of human chorionic gonadotropin.

A novel multi-channel 2 x 5 model of piezoelectric quartz micro-array immunosensor has been developed for quantitative detection of human chorionic gonadotropin (hCG) in serum or urine samples. Every crystal unit of the fabricated piezoelectric hCG micro-array immunosensor can oscillate independently without interfering each other. A 2 x 5 model of micro-array immunosensor as compared with a one-channel immunosensor can provide eight times higher detection speeds for hCG assay. The anti-hCG antibody is deposited on the gold electrode's surface of 10 MHz quartz AT-cut crystal by self-assembled technique using sulfosuccinimidyl 6-[3'-(2-pyridyldithio) propionamido] hexanoate (Sulfo-LC-SPDP), and serves as an antibody recognizing layer. The highly ordered self-assembled monolayers (SAM) ensure well-controlled surface structure and offer many advantages to the performance of the sensor. Compared with conventional antibody immobilization methods, the amount and the reaction activity of antibody monolayer coated by the SAM binding are bigger than those by the SPA method, and less non-specific binding caused by other analytes in sample is found. Under the optimized experimental conditions, the results showed that micro-array immunosensor quantitatively detected serum or urine hCG in the range of 2.5-500 mIU/ml with high precision (CV<5%); other hormones in human serum and urine did not interfere with the determination markedly. Serum and urine samples of 60 patients were detected by the micro-array immunosensor, and the results agreed well with those given by the commercial radioimmunoassay test kit, with correlation coefficient of 0.92. After regeneration with urea solution the coated immunosensor can be reused five times without appreciable loss of activity.

Biosensing Techniques↗