PubMed Health⌕ Search

Biomedical subjects

Tianzhen Shen

Publications and source records attributed to Tianzhen Shen.

2 recordsLinked to original sources

[Computer aided intracranial aneurysm embolization with GDC].

OBJECTIVE: To establish an expert system that automatically generates optimal GDC selection program for the embolization of intracranial aneurysm. METHODS: Twenty highly cost-effective cases of intracranial aneurysm embolized with GDC dense packing were collected. Each of them contains information including aneurysm's volume measured by three-dimension digital subtraction angiography (3D DSA), aneurysm's location, maximum transverse diameter, maximum length diameter, and GDC selection program. An expert system made up of a case base, a mathematical model simulating experts' experience (established with the help of data mining techniques combining multi-layer perceptron network with polyhedrons in high dimensional space), and data envelopment analysis (DEA), was implemented. RESULTS: When the user inputted four required parameters (volume, location, maximum transverse diameter, and maximum length diameter) into the expert system and clicked the "program design" button, candidate GDC selection program(s) would be presented in the result box. CONCLUSION: Case base, data mining techniques, and DEA can be used to establish the expert system that automatically generates optimal GDC selection program for the embolization of intracranial aneurysm. Its clinical value needs to be further evaluated.

Adult↗

[Three dimensional digital subtraction angiography in volume embolization ratio measurement of densely packing experimental aneurysms].

OBJECTIVE: To calculate the volume embolization ratio of densely packing experimental aneurysms by three dimensional digital subtraction angiography (3D-DSA). METHODS: Six experimental crotch aneurysms were created microsurgically in the common carotid artery of white rabbits. Two weeks later, each aneurysm's volume was measured with 3D-DSA surface shaded display(SSD) and the correction of lacteprene balloon calibration method. In the same time, the aneurysms were densely packed with electric detachable coils. The volume of coils that were used in each aneurysm was calculated separately. The ratio of coils volume and aneurysm volume was the volume embolization ratio (VER). RESULTS: The aneurysms volumes measured by 3D DSA SSD ranged from 0.037 to 0.087 ml. The VER ranged from 23.5% to 32.5% (average 27.4%). CONCLUSION: The minimum VER of densely packing experimental crotch aneurysms with electronic detachable coils was 23.5%.

Angiography, Digital Subtraction↗