PubMed Health⌕ Search

Biomedical subjects

Tiina Reponen

Publications and source records attributed to Tiina Reponen.

At least 19 recordsLinked to original sources

The effect of home characteristics on dust antigen concentrations and loads in homes.

On-site home visits, consisting of a home inspection, dust sampling, and questionnaires were conducted in 777 homes belonging to an ongoing birth cohort study in Cincinnati, Ohio. Various home characteristics were investigated, and antigen levels (concentrations [microg/g] and loadings [microg/m(2)]; IU for cockroach allergen) in floor dust samples collected in child's primary activity room were analyzed by ELISA. Monoclonal antibodies were used for the analysis of cat, house dust mite, and cockroach allergens, and polyclonal antibodies for Alternaria and dog antigens. The relationship between the antigen levels and home characteristics was investigated through a generalized multiple regression model. More than half of the homes experienced mold/water damage. Cats and dogs were present in 19.7% and 31.1% of homes, respectively. More than 90% of homes had either carpet or area rug covering their floors. Among 777 homes, 87-92% of homes had measurable amount of Alternaria, cat, and dog allergen/antigen in house dust, whereas only 38% and 14% of homes had measurable levels of house dust mite and cockroach, respectively. Alternaria antigen level in house dust was not associated with visual mold/water damage, which was suspected to be one of the sources for this antigen in homes. Instead, the antigen level was high in samples taken in fall and in homes having dogs implicating that Alternaria antigen appears to be transported from outdoors to indoors. A high level was also measured in homes using a dehumidifier (these homes have experienced excessive humidity) and in-home venting of clothes dryer, which might be associated with microclimate affecting mold growth and spore release. The allergen/antigen level (both concentration and loading) of cat, dog and cockroach was significantly associated with the number of cats and dogs, or the appearance of cockroaches, respectively. High level of house dust mite allergen was measured in bedrooms and in homes using dehumidifier and no central forced air heating system. Having indoor plants was shown to reduce allergen levels. Carpeted floor was found to hold larger amount of antigens than non-carpeted floor. Antigen loading demonstrated more consistent and larger numbers of associations with home characteristics compared to antigen concentration. This study encompassed a wide range of home characteristics and various antigen types. Our findings provide information on home characteristics that can be used for allergen avoidance and in planning future exposure assessment studies.

Air Pollution, Indoor↗

Physical collection efficiency of filter materials for bacteria and viruses.

The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10-900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10-600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-microm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.

Air Microbiology↗

Relative moldiness index as predictor of childhood respiratory illness.

The results of a traditional visual mold inspection were compared to a mold evaluation based on the Relative Moldiness Index (RMI). The RMI is calculated from mold-specific quantitative PCR (MSQPCR) measurements of the concentration of 36 species of molds in floor dust samples. These two prospective mold evaluations were used to classify the mold condition in 271 homes of infants. Later, the development of respiratory illness was measured in the infants living in these homes and the predictive value of each classification system was evaluated. The binary classification of homes as either moldy or non-moldy by on-site visual home inspection was not predictive of the development of respiratory illness (wheeze and/or rhinitis) (P=0.27). Conversely, a method developed and validated in this paper, using the RMI index fit to a logistic function, can be used to predict the occurrence of illness in homes and allows stake-holders the choice among various levels of risk.

Fungi↗

Influence of dog ownership and high endotoxin on wheezing and atopy during infancy.

BACKGROUND: Increased exposure to microbial products early in life may protect from development of atopic disorders in childhood. Few studies have examined the relationship of endotoxin exposure and pet ownership on atopy and wheezing during infancy. OBJECTIVE: Evaluate relationships among high endotoxin exposure, pet ownership, atopy, and wheezing in high-risk infants. METHODS: Infants (n = 532; mean age, 12.5 +/- 0.8 months) with at least 1 parent with confirmed atopy were recruited. A complete medical history and skin prick testing to foods and aeroallergens were performed at age 1 year. House dust samples were analyzed for endotoxin. RESULTS: Prevalences of wheezing were not independently associated with dog or cat ownership or endotoxin levels. Percutaneous reactivity to at least 1 allergen was observed in 28.6% of infants. Univariate analyses showed significant associations of any wheezing, recurrent wheezing, and recurrent wheezing with an event with daycare attendance, number of siblings, respiratory infections, maternal smoking, and history of parental asthma. Logistic regression adjusting for the latter variables showed that recurrent wheezing (odds ratio, 0.4; 95% CI, 0.1-0.9) as well as 2 other wheeze outcomes were significantly reduced in homes with high endotoxin exposure in the presence of 2 or more dogs. CONCLUSION: Pet ownership or endotoxin did not independently modify aeroallergen sensitization or wheezing during infancy. However, high endotoxin exposure in the presence of multiple dogs was associated with reduced wheezing in infants. CLINICAL IMPLICATIONS: A home environment with many dogs and high levels of endotoxin may be conducive to reduced wheezing in infancy.

Allergens↗

Analysis of short-term influences of ambient aeroallergens on pediatric asthma hospital visits.

The objective of our study was to investigate the association between daily pediatric asthma hospital visits and daily concentrations of aeroallergens and their specific species. Records of daily asthma visits in Cincinnati area were retrieved from Cincinnati Children's Hospital Medical Center and aeroallergen sampling was performed by the Button Inhalable Sampler. The Poisson generalized linear model was carried out in which the log of the number of asthma hospital visits was related to aeroallergen level, treated as a continuous variable with adjustment for seasonal time trend, day of the week, ozone and PM(2.5) concentrations, temperature and humidity. The aeroallergens having a significant impact on asthma hospital visits were ragweed, oak/maple and Pinaceae pollen. Their relative risks on asthma hospital visits with respect to a 100 counts/m(3) increase in concentration were in the range of 1.23 to 1.54. The effects in causing the asthma exacerbation were delayed by 3 or 5 days.

Acer↗

Estimating sampling frequency in pollen exposure assessment over time.

A time series model was fitted to the pollen concentration data collected in the Greater Cincinnati area for the Cincinnati Childhood Allergy and Air Pollution Study (CCAAPS). A traditional time series analysis and temporal variogram approach were applied to the regularly spaced databases (collected in 2003) and irregularly spaced ones (collected in 2002), respectively. The aim was to evaluate the effect of the sampling frequency on the sampling precision in terms of inverse of standard error of the overall level of mean value across time. The presence of high autocorrelation in the data was confirmed and indicated some degree of temporal redundancy in the pollen concentration data. Therefore, it was suggested that sampling frequency could be reduced from once a day to once every several days without a major loss of sampling precision of the overall mean over time. Considering the trade-offs between sampling frequency and the possibility of sampling bias increasing with larger sampling interval, we recommend that the sampling interval should take values from 3 to 5 days for the pollen monitoring program, if the goal is to track the long-term average.

Air Pollution↗

Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks?

BACKGROUND: Respiratory protection devices are used to protect the wearers from inhaling particles suspended in the air. Filtering face piece respirators are usually tested utilizing nonbiologic particles, whereas their use often aims at reducing exposure to biologic aerosols, including infectious agents such as viruses and bacteria. METHODS: The performance of 2 types of N95 half-mask, filtering face piece respirators and 2 types of surgical masks were determined. The collection efficiency of these respiratory protection devices was investigated using MS2 virus (a nonharmful simulant of several pathogens). The virions were detected in the particle size range of 10 to 80 nm. RESULTS: The results indicate that the penetration of virions through the National Institute for Occupational Safety and Health (NIOSH)-certified N95 respirators can exceed an expected level of 5%. As anticipated, the tested surgical masks showed a much higher particle penetration because they are known to be less efficient than the N95 respirators. The 2 surgical masks, which originated from the same manufacturer, showed tremendously different penetration levels of the MS2 virions: 20.5% and 84.5%, respectively, at an inhalation flow rate of 85 L/min. CONCLUSION: The N95 filtering face piece respirators may not provide the expected protection level against small virions. Some surgical masks may let a significant fraction of airborne viruses penetrate through their filters, providing very low protection against aerosolized infectious agents in the size range of 10 to 80 nm. It should be noted that the surgical masks are primarily designed to protect the environment from the wearer, whereas the respirators are supposed to protect the wearer from the environment.

Air Microbiology↗

Mold damage in homes and wheezing in infants.

BACKGROUND: In most studies that investigate the association of mold or water damage and respiratory disorders in infants, the analysis is not adjusted for exposure to house dust mite (HDM), which is also a known cause of respiratory illnesses. OBJECTIVE: To investigate the relationship between visually observable mold or water damage and HDM (Der f 1) levels and the prevalence of lower respiratory tract symptoms and allergen sensitization in infants of atopic parents as part of a prospective birth cohort study. METHODS: On-site home visits (at the infants' age of 8 months) were performed to evaluate observable mold or water damage and HDM exposure. At a clinic visit near the infant's first birthday, medical histories, including parent-reported wheezing episodes, and a skin prick test to food and 15 common aeroallergens were conducted in 640 infants. RESULTS: More than half of the homes were found to have mold or water damage, and 5% had major mold or water damage with visible mold at 0.2 m2 or more. Only 16% of homes had a HDM allergen (Der f 1) concentration of more than 2 microg/g. Major mold or water damage increased the risk of recurrent wheezing nearly 2 times in infants, 5 times in food or aeroallergen-sensitized infants, and 6 times in aeroallergen-sensitized infants. Neither visible mold or water damage nor HDM exposure was associated with sensitization to either mold or aeroallergens. CONCLUSIONS: Visible mold was shown to be a significant risk factor for recurrent wheezing in infants at high risk of developing atopic disorders, whereas HDM exposure did not significantly increase the risk.

Allergens↗

Personal exposure to airborne dust and microorganisms in agricultural environments.

Airborne dust and microorganisms are associated with respiratory diseases and increased mortality and morbidity. Farmers are at high risk of exposure to both of these hazards. Very limited information, however, is available on the combined exposures to both hazards on different types of farms. Moreover, most of the previous studies have measured the mass concentration of particles ignoring the particle size. In this study, farmers' exposure to airborne dust and microorganisms was studied using our newly developed personal sampling system. Particle number concentration and size distribution were measured with an optical particle counter. Simultaneously, particles were collected on a filter and analyzed for microorganisms. The field measurements were conducted in animal confinements (swine, poultry, and dairy) and during grain harvesting (corn and soybean). The results show the following average concentrations on the workers' breathing zone: 1.7 x 10(6) to 2.9 x 10(7) particles/m(3) for total dust, 0.9 x 10(3) to 3.9 x 10(4) spores/m(3) for total fungal spores, 0.3 x 10(3) to 3.6 x 10(4)CFU/m(3) for culturable fungal spores, 0.3 x 10(4) to 3.3 x 10(8) CFU/m(3) for culturable bacteria, and limit of detection (LOD) to 2.8 x 10(3) CFU/m(3) for culturable actinomycetes in animal confinements. The respective concentrations were 4.4 x 10(6) to 5.8 x 10(7) particles/m(3), 3.4 x 10(4) to 6.1 x 10(6) spores/m(3), 8.2 x 10(4) to 7.4 x 10(6) CFU/m(3), 0.4 x 10(5) to 1.4 x 10(6) CFU/m(3), and LOD to 2.6 x 10(4) CFU/m(3) during grain harvesting. The highest contribution of large particles (3-10 microm) in total particles was found during grain harvesting, whereas the size distribution was dominated by smaller particles (< 3 microm) in animal confinements. High fraction (up to 37%) of particles between 2-10 microm was found to be fungal spores. The results indicate that an increase in the concentration of large dust particles (2-10 microm) during grain harvesting was partially attributed to the increase in the concentration of the fungal spores. Overall, the combined exposure to airborne dust and microorganisms was found to be more severe during harvesting than in animal confinements.

Aerosols↗

Assessment of fungal contamination in moldy homes: comparison of different methods.

In an effort to better understand the relationship between different fungal sampling methods in the indoor environment, four methods were used to quantify mold contamination in 13 homes with visible mold. Swab, fungal spore source strength tester (FSSST), and air samples (total of 52 samples) were analyzed using both the microscopic (total spore count) and culture-based (CFU count) enumeration techniques. Settled dust samples were analyzed for culturable fungi only, as the microscopic enumeration was restricted by the masking effect. The relationships between the data obtained with the different sampling methods were examined using correlation analysis. Significant relationships were observed between the data obtained from swab and FSSST samples both by the total counting (r = 0.822, p < 0.05) and by the CFU counting (r = 0.935, p < 0.01). No relationships were observed between air and FSSST samples or air and settled dust samples. Percentage culturability of spores for each sampling method was also calculated and found to vary greatly for all three methods (swab: 0.03% to 63%, FSSST: 0.1% to > 100%, air: 0.7% to 79%). These findings confirm that reliance on one sampling or enumeration method for characterization of an indoor mold source might not provide an accurate estimate of fungal contamination of a microenvironment. Furthermore, FSSST sampling appears to be an effective measurement of a mold source in the field, providing an upper bound estimate of potential mold spore release into the indoor air. Because of the small sample size of this study, however, further research is needed to better understand the observed relationships in this study.

Air Microbiology↗

Environmental risk factors of rhinitis in early infancy.

Previous studies of allergic rhinitis in children have not documented the environmental risk factors for infants at age one. We examined the relationship of environmental tobacco smoke (ETS) and visible mold exposures on the development of allergic rhinitis, rhinitis and upper respiratory infection (URI) in a birth cohort where at least one parent was skin prick test (SPT) positive. ETS exposure and upper respiratory symptoms were obtained by questionnaires. Visible mold was classified as none, low or high during home visit. Infants had a SPT at age one. After adjustment for potential confounders, exposure to >20 cigarettes per day was associated with an increased risk of developing allergic rhinitis at age one [odds ratio (OR)=2.7; 95% CI 1.04-6.8] and rhinitis symptoms during the first year (OR=1.9; 95% CI 1.1-3.2). Infants with low (OR=1.5; 95% CI 1.1-2.3) or high (OR=5.1; 95% CI 2.2-12.1) levels of visible mold in their homes were more likely to have more frequent URI during the first year. Older siblings were protective for development of both rhinitis symptoms and allergic rhinitis. This study suggests that ETS exposure, rather than visible mold, is associated with rhinitis and allergic rhinitis in infants. The analysis also suggests that mold may be a stronger risk factor for URI that ETS.

Causality↗

Specific fungal exposures, allergic sensitization, and rhinitis in infants.

Indoor air quality has become increasingly important as we live in a society where the majority of our time is spent indoors. Specific attention has been drawn to airborne fungal spores as a factor affecting indoor air quality. This study targeted shortcomings of other studies by utilizing long-term air sampling and total fungal spore enumeration to determine associations between health outcomes and fungal spore concentrations. Infants (n = 144) were clinically evaluated and had skin prick tests (SPT) for 17 allergens. Airborne fungal spores were collected using a Button Personal Inhalable Sampler (SKC Inc.) for 48 h at a flow rate of 4 l/min. Sampling was conducted in the spring (March-May) or fall (August-October) in 2003-2004. Fungal spores were analyzed using microscopy-based total counting and identified to the genus/group level. Total spore and individual genus concentrations were analyzed for associations with rhinitis and positive SPT results. Overall, concentrations varied widely, between <2 and 2294 spores/m(3). While no relationship was observed between SPT(+) and total fungal counts, several significant associations were found when analysis was conducted on the various fungal genera and health outcomes. Positive associations were obtained between: Basidiospores and rhinitis (p < 0.01), Penicillium/Aspergillus and SPT(+) to any allergen (p < 0.01), and Alternaria and SPT(+) to any allergen (p < 0.01). Inverse associations were found between: Cladosporium and SPT(+) to any allergen (p < 0.05), and Cladosporium and SPT(+) to aeroallergens (p < 0.05). This study indicates that health outcome may vary by fungal genera; some fungal types may have sensitizing effects while others may have a beneficial role.

Air Microbiology↗

Mold and endotoxin levels in the aftermath of Hurricane Katrina: a pilot project of homes in New Orleans undergoing renovation.

BACKGROUND: After Hurricane Katrina, many New Orleans homes remained flooded for weeks, promoting heavy microbial growth. OBJECTIVES: A small demonstration project was conducted November 2005-January 2006 aiming to recommend safe remediation techniques and safe levels of worker protection, and to characterize airborne mold and endotoxin throughout cleanup. METHODS: Three houses with floodwater lines between 0.3 and 2 m underwent intervention, including disposal of damaged furnishings and drywall, cleaning surfaces, drying remaining structure, and treatment with a biostatic agent. We measured indoor and outdoor bioaerosols before, during, and after intervention. Samples were analyzed for fungi [culture, spore analysis, polymerase chain reaction (PCR)] and endotoxin. In one house, realtime particle counts were also assessed, and respirator-efficiency testing was performed to establish workplace protection factors (WPF). RESULTS: At baseline, culturable mold ranged from 22,000 to 515,000 colony-forming units/m3, spore counts ranged from 82,000 to 630,000 spores/m3, and endotoxin ranged from 17 to 139 endotoxin units/m3. Culture, spore analysis, and PCR indicated that Penicillium, Aspergillus, and Paecilomyces predominated. After intervention, levels of mold and endotoxin were generally lower (sometimes, orders of magnitude). The average WPF against fungal spores for elastomeric respirators was higher than for the N95 respirators. CONCLUSIONS: During baseline and intervention, mold and endotoxin levels were similar to those found in agricultural environments. We strongly recommend that those entering, cleaning, and repairing flood-damaged homes wear respirators at least as protective as elastomeric respirators. Recommendations based on this demonstration will benefit those involved in the current cleanup activities and will inform efforts to respond to future disasters.

Air Microbiology↗

Manikin-based performance evaluation of N95 filtering-facepiece respirators challenged with nanoparticles.

Protection of the human respiratory system from exposure to nanoparticles is becoming an emerging issue in occupational hygiene. The potential adverse health effects associated with particles of approximately 1-100 nm are probably greater than submicron or micron-sized particles. The performance of two models of N95 half-facepiece-filtering respirators against nano-sized particles was evaluated at two inhalation flow rates, 30 and 85 l min(-1), following a manikin-based protocol. The aerosol concentration was measured outside and inside the facepiece using the Wide-Range Particle Spectrometer. Sodium chloride particles, conventionally used to certify N-series respirators under NIOSH 42 CFR 84 regulations, were utilized as the challenge aerosol. The targeted particle sizes ranged from 10 to 600 nm, although the standard certification tests are performed with particles of approximately 300 nm, which is assumed to be the most penetrating size. The results indicate that the nanoparticle penetration through a face-sealed N95 respirator may be in excess of the 5% threshold, particularly at high respiratory flow rates. Thus, N95 respirators may not always provide the expected respiratory protection for workers. The highest penetration values representing the poorest respirator protection conditions were observed in the particle diameter range of approximately 30-70 nm. Based on the theoretical simulation, we have concluded that for respirators utilizing mechanical filters, the peak penetration indeed occurs at the particle diameter of approximately 300 nm; however, for pre-charged fiber filters, which are commonly used for N95 respirators, the peak shifts toward nano-sizes. This study has confirmed that the neutralization of particles is a crucial element in evaluating the efficiency of a respirator. The variability of the respirator's performance was determined for both models and both flow rates. The analysis revealed that the coefficient of variation of the penetration ranged from 0.10 to 0.54 for particles of 20-100 nm in diameter. The fraction of N95 respirators for which the performance test at 85 l min(-1) demonstrated excessive (>5%) penetration of nanoparticles was as high as 9/10. The test results obtained in a relatively small (0.096 m(3)) test chamber and in a large (24.3 m(3)) walk-in chamber were found essentially the same, thus, suggesting that laboratory-based evaluations have a good potential to adequately represent the respirator field performance.

Aerosols↗

Correlation of ambient inhalable bioaerosols with particulate matter and ozone: a two-year study.

In this study, we have examined the relationships between the concentrations of ambient inhalable airborne fungi and pollen with PM10, PM2.5, ozone, organic carbon, selected trace metals (cadmium, copper, lead, and zinc), temperature, and relative humidity. The database was collected in Cincinnati, Ohio, USA, during two consecutive years. Measurements of all environmental variables were performed at the same site continuously 5 days a week except during winter months. The airborne concentrations of biological and non-biological pollutants ranged as follows: total fungi: 184-16 979 spores m(-3); total pollen: 0-6692 pollen m(-3); PM10: 6.70-65.38 microg m(-3); PM2.5: 5.04-45.02 microg m(-3); and ozone: 2.54-64.17 ppb. Higher levels of total inhalable fungi and particulate matter were found during fall and summer months. In contrast, total pollen concentration showed elevated levels in spring. Peak concentrations of ozone were observed during summer and beginning of fall. Our study concluded that several types of inhalable airborne fungi and pollen, particulate matter, and ozone could be positively correlated as a result of the atmospheric temperature influence.

Aerosols↗

The effect of filter material on bioaerosol collection of Bacillus subtilis spores used as a Bacillus anthracis simulant.

The objective of this study was to determine filter materials and extraction methods that are appropriate to use for environmental sampling of B. anthracis. Four types of filters were tested: mixed cellulose ester (MCE) with a pore size of 3 microm, polytetrafluoroethylene (PTFE) with pore sizes of 1 and 3 microm, and gelatin with a pore size of 3 microm. Bacillus subtilis var. niger endospores (also known as Bacillus globigii[BG]) were used as a surrogate for B. anthracis. Endospores were collected into Button Inhalable Aerosol Samplers with sampling times of 15 minutes, 1 hour, and 4 hours. Physical collection efficiency was determined by measuring upstream and downstream B. subtilis concentrations with an optical particle counter. Vortexing with ultrasonic agitation and vortexing with shaker agitation extraction methods were evaluated. The MCE, 1 microm PTFE, and gelatin filters provided physical collection efficiencies of 94% or greater. The 3 microm PTFE filter showed inconsistent physical efficiency characteristics between filters. Epifluorescence microscopic analysis of the gelatin filter extraction fluid revealed the presence of contamination by non-culturable bacteria. Mean differences for microbial culturability were not statistically significant for filter materials and extraction methods. However, the vortexing with shaker agitation extraction method resulted in higher total microbial counts in the extraction fluids for MCE and 1 microm PTFE filters when compared to vortexing with ultrasonic agitation. In summary, the MCE and 1 microm PTFE filters in combination with vortexing and shaker extraction demonstrated the best performance for the filter collection and extraction of BG spores.

Aerosols↗

Laboratory and field evaluation of a new personal sampling system for assessing the protection provided by the N95 filtering facepiece respirators against particles.

OBJECTIVES: We have recently developed a new personal sampling system for the real-time measurement of the protection provided by respirators against airborne dust and micro-organisms. The objective of this study was to evaluate the performance characteristics of the new sampling system in both laboratory and field conditions. METHODS: The measurements were conducted using the N95 filtering facepiece respirators and the newly developed personal sampling system put on a manikin (laboratory study) or donned by a human subject (laboratory and field studies). Two inhalation flow rates (0 and 40 l min(-1)) in conjunction with the sampling flow rate (10 l min(-1)) were tested in the manikin-based experiments to investigate the effects of the leak location (nose, cheek and chin) and the depth of the sampling probe (0, 5, 10 and 15 mm) within the respirator. The effect of human activity on the protection factor was evaluated using a variety of head movements and breathing patterns when a human subject wore the respirator in a room-size laboratory test chamber. The field study was conducted during corn harvesting with a respirator worn by a human subject on a combine. RESULTS: There was no significant difference in the protection factors for different leak locations, or for sampling probe depths, when the inhalation rate was 0 l min(-1). For the inhalation rate of 40 l min(-1), the protection factors for nose leaks were higher than those for chin and cheek leaks. Furthermore, the protection factor was the lowest and showed the least variation when the sampling probe depth was equal to 0 mm (imbedded on the respirator surface). Human subject testing showed that the grimace maneuver decreased the protection factor and changed the original respirator fit. The protection factor during breath holding was lower than that found during inhalation and exhalation. Field results showed greater variation than laboratory results. CONCLUSIONS: The newly designed personal sampling system efficiently detected the changes in protection factors in real time. The sampling flow was least affected by the inhalation flow when the sampling probe was imbedded on the respirator surface. Leak location, breathing patterns and exercises did affect the measurement of the protection factors obtained using an N95 filtering facepiece respirator. This can be attributed to the differences in the in-mask airflow dynamics contributed by the leak, filter material, sampling probe and inhalation. In future studies, it would be beneficial if the laboratory data could be integrated with the field database.

Equipment Design↗

Respiratory protection provided by N95 filtering facepiece respirators against airborne dust and microorganisms in agricultural farms.

A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increasing particle size ranging from 21 for 0.7-1 microm particles to 270 for 5-10 microm particles (p < 0.001). The WPF for total culturable fungi (GM = 35) was significantly greater than for total culturable bacteria (GM = 9) (p = 0.01). Among the different microorganism groups, the WPFs of Cladosporium, culturable fungi, and total fungi were significantly correlated with the WPFs of particles of the same sizes. As compared with the WPFs for dust particles, the WPFs for bioaerosols were found more frequently below 10, which is a recommended assigned protection factor (APF) for N95 filtering facepiece respirators. More than 50% of the WPFs for microorganisms (mean aerodynamic diameter < 5 microm) were less than the proposed APF of 10. Even lower WPFs were calculated after correcting for dead space and lung deposition. Thus, the APF of 10 for N95 filtering facepiece respirators seems inadequate against microorganisms (mean aerodynamic size < 5 microm). These results provide useful pilot data to establish guidelines for respiratory protection against airborne dust and microorganisms on agricultural farms. The method is a promising tool for further epidemiological and intervention studies in agricultural and other similar occupational and nonoccupational environments.

Agriculture↗