PubMed Health⌕ Search

Biomedical subjects

Tijani Gharbi

Publications and source records attributed to Tijani Gharbi.

15 recordsLinked to original sources

Blood volume and haemoglobin oxygen content changes in human bone marrow during orthostatic stress.

The interest in, and the need for effective measures to be used in screening, diagnosis, and the follow-up of skeletal pathologies is growing markedly. This paper proposes a completely new and non-invasive technique allowing the study of the human tibia bone marrow (BM) haemodynamics with a time resolution of 1 s. The technique, based on near infrared spectroscopy, is sensitive enough to allow the detection of BM blood volume and/or oxygen saturation changes during orthostatic variations imposed by a tilt bed. An increase in the slope of the bed of 15 degrees is sufficient to detect this phenomenon. The ability to study the possible presence of a neural control of BM haemodynamics is also discussed. No other existing technique currently allows one to obtain the proposed results and this approach might open up a new field of study related to human BM physiology.

Adult↗

Age-related changes in skin topography and microcirculation.

Skin topography and microvasculature undergo characteristic changes with age. Although several non-invasive bioengineering methods are currently available to measure them quantitatively, few publications have referred to their relationship with age in different anatomical sites. This study was carried out to observe the age-related changes of the skin topography and skin microcirculation. The microrelief was assessed with special processing software from scanning by interference fringe profilometry of silicone replicas performed on two sites (volar forearm and back of hand) on 50 female volunteers (aged 20-74 years who consisted of ten probands in each decade). The superficial vascular network of both sites was assessed by videocapillaroscopy, and the subpapillary vascular plexus was studied with laser Doppler flowmetry. Skin color, which is affected by blood flow, was observed by colorimeter. The skin roughness and the mean height between peak and valley increased with age. There were statistically significant differences between the evaluated sites. This study also shows that the capillary loops in the dermal papillae decrease but the subpapillary plexus increase with age. The interference fringe profilometry associated with videocapillaroscopy may be useful and accurate to measure the efficacy of medical or cosmetic products to delay skin aging.

Adult↗

Tensorial analysis of a Fourier-transform profilometric setup devoted to the evaluation of muscular contractions.

We explore the potential use of the Fourier-transform profilometry technique in in vivo studies of muscular contractions through the variation of muscle-group cross sections. Thanks to a tensorial analysis of the technique, a general expression of its sensitivity vector is established. It allows derivation of the expression of the resolution and the limit condition imposed by the spatial sampling of the fringe pattern. Key parameters that maximize the sensitivity are then simulated. A measurement system is accordingly built up and characterized. It is then successfully applied to the evaluation of the deformation of the forearm muscles during grasping exertions.

Algorithms↗

Contractile forces generated by striae distensae fibroblasts embedded in collagen lattices.

Striae distensae are characterized by linear, smooth bands of atrophic-appearing skin that are reddish at first and finally white. They are due to stretching of the skin, as in rapid weight gain, or mechanical stress, as in weight lifting. The pathogenesis of striae distensae is unknown but probably relates to changes in the fibroblast phenotype. In order to characterize striae distensae fibroblasts, alpha-smooth muscle actin expression and contractile forces were studied. Five healthy women with early erythematous striae and five healthy women with older striae were selected. Paired biopsies were taken from the center of lesional striae and adjacent normal skin. Fibroblasts were obtained by an explant technique and expanded in vitro in Dulbecco's modified Eagle's medium. Contractile forces generated by fibroblasts in collagen lattices were measured with the Glasbox device developed in our laboratory. Alpha-smooth muscle actin expression was studied by immunofluorescence labeling of cells and by flow cytometry. Fibroblasts from early striae distensae were the richest cells in alpha-smooth muscle actin filaments and generated the highest contractile forces. Their peak contractile force was 26% greater than normal fibroblasts. There was a 150% higher level of alpha-smooth muscle actin content in fibroblasts from early striae distensae compared with fibroblasts from normal skin. In contrast, there was no significant difference in force generation between old striae fibroblasts and normal fibroblasts with cells expressing no alpha-smooth muscle actin. The contractile properties of fibroblasts from striae distensae varies depending on the stage of the disease. In early striae distensae, fibroblasts acquire a more contractile phenotype, corresponding to that of myofibroblasts.

Actins↗

In vivo measurement of lower back deformations with Fourier-transform profilometry.

Through the variation of their cross sections, the in vivo response of lower back muscles to low loading in an upright seated posture is explored by the Fourier-transform profilometry technique. The maximization of its sensitivity allows us to reach an adequate resolution for the evaluation of low-back displacements. Refinements of the fringe pattern analysis permit the minimization of errors. The experiments show an asymmetric distribution of the displacement during head rotation movements. Significant contribution of the lower back to grasping exertions is also observed. These results are thought to be useful for early defect detection in the lower back.

Anatomy, Cross-Sectional↗

Phase-unwrapping algorithm for images with high noise content based on a local histogram.

We present a robust algorithm of phase unwrapping that was designed for use on phase images with high noise content. We proceed with the algorithm by first identifying regions with continuous phase values placed between fringe boundaries in an image and then phase shifting the regions with respect to one another by multiples of 2pi to unwrap the phase. Image pixels are segmented between interfringe and fringe boundary areas by use of a local histogram of a wrapped phase. The algorithm has been used successfully to unwrap phase images generated in a three-dimensional shape measurement for noninvasive quantification of human skin structure in dermatology, cosmetology, and plastic surgery.

Algorithms↗

Skin capillary network recognition and analysis by means of neural algorithms.

BACKGROUND: The intra-dermal capillary network can be easily assessed by a computerized videomicroscope system. Nevertheless, finding capillary loops automatically in an image is a difficult yet important first step in order to achieve microcirculation analysis. METHODS: A detection system was tested by combining videocapillaroscopy and principal component analysis (PCA). Our goal was to build a generic detector of capillary associated with a retinally connected neural network filter. The filter examines small windows of an image, and decides with this detector whether each window contains a capillary or not. RESULTS: Comparisons with manual detections showed that the system has a detection rate of 82% on test set A containing 100 good-quality images of the scalp. A detection rate of 65% was obtained on test set B containing 50 images with noisy background and large artifacts. The performance was increased by a color detector with a detection rate of 71% on the last test. These results correspond to a false detection rate lower than or equal to 10%. CONCLUSION: This neural filter system is capable of real-time processing; it recognizes capillaries anywhere in an image, and operates successfully under wide range of lighting and noisy conditions.

Algorithms↗

Production and validation of CR-39-based dishes for alpha-particle radiobiological experiments.

The study of radiobiological effects induced in vitro by low fluences of alpha particles would be significantly enhanced if the precise localization of each particle track in the cell monolayer was known. From this perspective, we developed a new method based on tailor-made UV-radiation-cured CR-39, the production of which is described. Its validation both as a petri dish and as solid-state nuclear track detectors is demonstrated. With respect to the demands on solid-state nuclear track detectors in such experiments, these biologically compatible detectors have a controlled micrometric thickness that allows them to be crossed by the alpha particles. In this study, we present a method for obtaining 10-mum-thick CR-39, its chemical characterization, and its properties as a solid-state nuclear track detector under the environmental conditions of radiobiological experiments. The experimental studies performed with 3.5 MeV alpha particles show that their transmitted energy is sufficient enough to cross the entire cellular volume. Under optimal conditions, etched tracks are clearly defined 2 h after etching. Moreover, the UV-radiation-cured CR-39 represents an essentially zero background that is due to the short time between the production and use of the polymer. Under a confocal microscope, this thin solid-state nuclear track detector allows the precise localization of the impact parameter at the subcellular level.

Alpha Particles↗

Towards objective evaluation of the skin aspect: principles and instrumentation.

BACKGROUND/AIMS: The aim of this paper is to propose an objective procedure for the evaluation of the skin aspect. This work is based on light scattering phenomena and in-vivo measurements of the skin profile and of the skin Bi-directional Reflection Distribution Function (BRDF). METHODS: We consider the basic mechanisms of light reflection and scattering by a surface to extract the key sur-face-parameters of aspect. It appears that the surface relief is determinant for the local surface orientation while the light scattering properties of the skin are responsible for the visibility of that skin relief. The first part presents the principles of skin-image formation on the retina and de-scribes the actual roles of the BRDF and of the skin relief. The second part is dedicated to experimental measurements on the skin in vivo. The 3D relief is reconstructed by a fringe projection method and numerical processing. The angular distribution of light reflected by the skin is also measured by means of a different set-up. RESULTS: The knowledge of both the skin relief obtained by 3D optical profilometry and the skin scattering behavior measured for regularly distributed set angle values, allows an objective aspect evaluation as well as a prediction of the skin images that an observer will receive. CONCLUSION: This paper presents both the principles and instrumentation elements suitable for the setting up of an objective evaluation procedure of the skin aspect.

Dermoscopy↗

Assessment of spray application of Saint GERVAIS water effects on skin wettability by contact angle measurement comparison with bidistilled water.

BACKGROUND: The skin is responsible for protecting the body from physical, chemical and microbial injuries. The stratum corneum is the top layer of the epidermis and it plays a key role in helping to contain moisture. When the skin becomes damaged, its ability to perform these functions is compromised. Dry skin is a common form of skin damage. Contact angle 0 between a surface and water is a good indicator of hydrophobic or hydrophilic tendency of surfaces. OBJECTIVE: To quantify the influence of spray application of an isotonic mineral water (Saint GERVAIS water) on the hydrophobic tendency of dry skin and to compare spreading of both types of water on the skin through 0 measurement of each water drop on the skin before and after mineral spray application. MATERIALS AND METHODS: Contact angles theta between skin surface and the two types of water (bidistilled and mineral water) were measured before and after application of mineral water by a system allowing the measurement of theta in vivo and in vitro. The cutaneous hydration, the temperature and pH were also measured before and after mineral water application. RESULTS: As for the application of mineral water, the cutaneous pH significantly increased so the strong skin acidity decreased. The cutaneous temperature was modified (a decrease of 2 degrees C was noted) and the cutaneous hydration was also increased (+47AU). The hydro-phobic tendency of the dry skin tested in this study was strongly decreased after mineral water application. This parameter was illustrated by a decrease of contact angle theta value. CONCLUSION: Saint GERVAIS water application allowed a regulation of skin pH, a fresh sensation on the skin and an increase in the cutaneous hydration. Moreover, the contact angle measurement with bidistilled water illustrated the increased wettability of the skin.

Administration, Topical↗

Influence of the hydrophobic and hydrophilic characteristics of sliding and slider surfaces on friction coefficient: in vivo human skin friction comparison.

INTRODUCTION: The objective of this study was to investigate whether hydrophilic/hydrophobic balance (Hi/Ho) of the skin surface strongly modifies the friction coefficient (mu). The Hi/Ho balance is determined using the relationship between the critical surface tension gammac (Zisman's principle:which delimits the wetting capacity) and the surface tension of water gammaH2O (water: reference element of Hi/Ho balance). METHOD: Critical surface tension gammac was determined (according to Zisman's principle) through the measurement of advancing contact angle theta of a series of ethanol/water dilutions. Friction coefficient depends on several parameters: types of probe motions (rotational vs. linear), surface roughness and physicochemical parameters of surfaces in contact). In this study, the wettability parameters for six surfaces (human skin forearm, Teflon, silicone impression material 'Silflo', vinyl polysiloxane impression material 'resin' steel and glass) were measured and their influences were compared to friction coefficient mu. RESULTS: This study shows that the higher hydrophobia tendency of the surfaces, the lower friction coefficient. The use of three sliding materials (Teflon, steel and glass) of different Hi/Ho balance confirms the importance of these physicochemical parameters in mu. For example, Teflon with high hydrophobia has a low mu. Friction coefficient increased when hydrophobia of sliding and slider surfaces decreased. CONCLUSION: Friction coefficient value depends on the type of slider surface and its physicochemical properties. In vivo,the friction coefficient may quantify the influence of lubrificant/emolients/moisturizers. For example, the friction coefficient of hydrated skin (through the action of moisturizing products) is higher than the friction coefficient of dry skin. The relationship between the friction coefficient and the Hi/Ho balance can be reversed in the presence of water and sebum on forehead, for example.

Adult↗

Pulsed local-field fluorescence microscopy: a new approach for measuring cellular signals in the beating heart.

In cardiac research, single-cell experimental models have been extensively used to study the molecular mechanisms of intracellular Ca(2+) homeostasis. The results of these studies are usually extrapolated to the tissue level assuming that the phenomena studied at the cellular level are either similar in the intact organ, or only slightly modified by variables that exist at the whole-heart level. The validity of these assumptions has rarely been confirmed experimentally. Common obstacles associated with the study of intracellular Ca(2+) signals in beating hearts include motion artifacts and spatio-temporal limitations of the recording system. In this work, action potentials and intracellular Ca(2+) signals were measured in beating hearts from young rats, with spatio-temporal resolutions similar to cellular studies using a novel pulsed local-field fluorescence technique. This method was based on maximizing emitted fluorescence to increase the signal-to-noise ratio (S/N). The fluorescence emission of the indicator molecules was synchronized with brief (<1 ns), high-power (400 W) laser pulses, and the common mode noise of the fluorescence signal was differentially cancelled. To follow rapidly evolving signals, a highly sensitive and fast detection system was used (10 kHz). The spatial resolution was improved using a small (50-200 microm diameter) multimode fiberoptic. Mechanical artifacts were effectively reduced by inserting the fiberoptic into a "floating" glass micropipette sealed to the heart wall with negative pressure. Our results demonstrate that local-field fluorescence microscopy offers an outstanding experimental approach for studying physiological signals at the whole-organ level with the high spatio-temporal resolution common to normal cellular approaches.

Action Potentials↗

Geometrical capillary network analysis.

BACKGROUND: Skin microcirculation, especially the superficial network, can be assessed by a computer capillary video microscope system. The study of morphology and dynamics of microcirculation must include all dynamic and cooperative processes between the capillaries. For characterizing capillary ensembles, the statistical and geometrical properties of the network need to be explored. METHODS: The microvaculature of the skin and the microcirculation were investigated by combining videocapillaroscopy (VCP) and image processing techniques based on computational geometry and graph theory. Our goal was to characterize the capillary network in noisy pictures of the scalp. Different geometric methods were developed, based on proximity parameters (distance and surface) in order to circumscribe and construct this network. RESULTS: By studying the distribution of these parameters, extreme values or outliers, which usually correspond to artifact subregions in the pictures could be eliminated. Different algorithms were developed and has been implemented in an image processing software (Capilab Toolbox). CONCLUSION: This computerized system is capable of real-time processings, increasing the quality of videocapillaroscope images and minimizing the disturbance of artifacts. The algorithms presented here are easy to implement and can process any kind of images of the skin, even in the scalp. In association with an example-based detection system, this method can be generalized to other stimuli in the same conditions.

Capillaries↗

High-accuracy position and orientation measurement of extended two-dimensional surfaces by a phase-sensitive vision method.

We introduced recently phase measurements usually performed in interferometry to the domain of image processing and intelligent vision [IEEE Trans. Instrum. Meas. 49, 867 (2000)]. Our purpose is to sense with a high accuracy the position, orientation, and displacement of two-dimensional (2D) surfaces observed by a static vision system. We report on significant improvements of the method. Experimental measurements reveal a peak-valley noise of approximately 10(-2) CCD pixel, corresponding approximately to a 10(-3) period of the phase reference pattern. Then the observation of 10 microm scaled features enables an accuracy of a few nm in the position sensing of the phase reference pattern for the extended 2D measurement range.

Journal Article↗

Three-dimensional optical high-resolution profiler with a large observation field: foot arch behavior under low static charge studies.

Our aim is to describe a method for detecting small deformations from a three-dimensional (3D) shape of large lateral dimensions. For this purpose the measurement method is based on the simultaneous utilization of several 3D optical systems and the phase-shifting technique. In this way, the following problems appear: optical distortion due to the large field observed, nonlinear phase-to-height conversion, conversion of image coordinates into object coordinates for each 3D optical system, and coordinate unification of all optical systems. The resolution is 50 microm with a field of view of 320 mm x 150 mm. We used this system to study the 3D human foot arch deformation under low loads in vivo. First results indicate the hysteresis behavior of the human foot under a low load (50 to 450 N).

Biomechanical Phenomena↗