Microsystem for transfection of exogenous molecules with spatio-temporal control into adherent cells.

Several non-viral techniques involving the use of liposomes, particle bombardment and electroporation have been used for efficient transfection of plasmids and other molecules into cells. Current approaches target whole or bulk regions of tissue, lacking the desired spatial control over the transfection process. In this study, we present a novel approach using microsystems to achieve spatial and temporal control over the transfection process in adherent cells. A 6x6 MEA (microelectrode array) with 100 microm microelectrode dimension was developed on a silicon substrate using standard microfabrication procedures and passivated with a biocompatible layer. Using finite element models, electric field intensities were simulated and locations of optimal electroporation zones in the cell culture on the microelectrode surface were predicted. The MEA was subsequently tested using 3T3 fibroblasts cultured on the MEA surface for 96 h and stimulation voltages in the range of 2-5 V in the presence of propidium iodide (PI), a cell impermeant dye. Maximum electric field intensities in the z-direction were estimated to be in the range of 320-820 V/cm for applied differential voltages in the range of 2-5 V. Cells directly on the top and on the edges of the stimulating microelectrodes in the MEA were preferentially transfected with PI as predicted by the simulations. The results of these experiments demonstrate that spatial and temporal control of desired regions of transfection in vitro can be achieved using MEAs and electroporation.

Animals↗

An array of microactuated microelectrodes for monitoring single-neuronal activity in rodents.

Arrays of microelectrodes used for monitoring single- and multi-neuronal action potentials often fail to record from the same population of neurons over a period of time for several technical and biological reasons. We report here a novel Neural Probe chip with a 3-channel microactuated microelectrode array that will enable precise repositioning of the individual microelectrodes within the brain tissue after implantation. Thermal microactuators and associated microelectrodes in the Neural Probe chip are microfabricated using the Sandia's Ultraplanar Multi-level MEMS Technology (SUMMiTV) process, a 5-layer polysilicon micromachining technology of the Sandia National labs, Albuquerque, NM. The Neural Probe chip enables precise bi-directional positioning of the microelectrodes in the brain with a step resolution in the order of 8.8 microm. The thermal microactuators allow for a linear translation of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The overall translation in either direction was reduced to approximately 2 mm after insulation of the microelectrodes with epoxy for monitoring multi-unit activity. Single unit recordings were obtained from the somatosensory cortex of adult rats over a period of three days demonstrating the feasibility of this technology. Further optimization of the microelectrode insulation and chip packaging will be necessary before this technology can be validated in chronic experiments.

Action Potentials↗

Electrostatic microactuators for precise positioning of neural microelectrodes.

Microelectrode arrays used for monitoring single and multineuronal action potentials often fail to record from the same population of neurons over a period of time likely due to micromotion of neurons away from the microelectrode, gliosis around the recording site and also brain movement due to behavior. We report here novel electrostatic microactuated microelectrodes that will enable precise repositioning of the microelectrodes within the brain tissue. Electrostatic comb-drive microactuators and associated microelectrodes are fabricated using the SUMMiT V (Sandia's Ultraplanar Multilevel MEMS Technology) process, a five-layer polysilicon micromachining technology of the Sandia National labs, NM. The microfabricated microactuators enable precise bidirectional positioning of the microelectrodes in the brain with accuracy in the order of 1 microm. The microactuators allow for a linear translation of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The overall translation was reduced to approximately 2 mm after insulation of the microelectrodes with epoxy for monitoring multiunit activity. The microactuators are capable of driving the microelectrodes in the brain tissue with forces in the order of several micro-Newtons. Single unit recordings were obtained from the somatosensory cortex of adult rats in acute experiments demonstrating the feasibility of this technology. Further optimization of the insulation, packaging and interconnect issues will be necessary before this technology can be validated in long-term experiments.