Timo Lövgren

Publications and source records attributed to Timo Lövgren.

26 records · Page 2Linked to original sources

One-step quantitative thyrotropin assay for the detection of hypothyroidism in point-of-care conditions.

OBJECTIVES: Different screening strategies for early diagnosis of hypothyroidism have been discussed increasingly. We demonstrate the applicability of a miniaturized microparticle assay format for rapid and quantitative determination of increased thyrotropin (TSH) concentrations in serum. DESIGN AND METHODS: Porous microparticles were used as solid phase for a noncompetitive, one-step, kinetic immunoassay with varying incubation times and time-resolved fluorescence detection. RESULTS: The analytical (mean of zero + 3 SD) and functional (CV <15%) detection limits were 1.5 and 6.0 mIU/L for 2-min, 0.5 and 1.5 mIU/L for 7-min, and 0.2 and 0.5 mIU/L for 15-min assays, respectively. A good correlation was found with the Chiron Diagnostics ACS:180 assay (slopes 0.885-1.051, y-intercepts < +/- 0.20 mIU/L, S(y logical or, bar below x) 0.98, n = 20). CONCLUSION: The kinetic TSH assay provides reproducible and quantitative information on thyroid status within minutes and is applicable for the detection of hypothyroidism in point-of-care (POC) conditions.

Calibration↗

A homogeneous high-throughput genotyping method based on competitive hybridization.

OBJECTIVES: A reliable high-throughput assay system is necessary for the analysis of the ever-increasing numbers of single-nucleotide polymorphisms (SNP) relevant to genetic screening studies. We describe an assay suitable also for large-scale screening programs. DESIGN AND METHODS: The one-step assay is based on asymmetric PCR amplification of the target sequence and subsequent time-resolved fluorescence measurement. Asymmetric amplification results in a single-stranded PCR product that is detected in the amplification vessel with a highly sensitive, homogeneous hybridization method. RESULTS: A dual label, homogeneous high-throughput platform for nucleic acid sequence analysis was developed and validated using a C/T single-nucleotide polymorphism in the insulin gene as a model analyte and applied also to two other SNP-assays (poliovirus receptor A/G-polymorphism and CD86-gene exon 2 A/G-polymorphism). CONCLUSIONS: The described high-throughput genotyping technology is very competitive in price, simple in design and easily applied to any analyte sequence.

Genetic Testing↗

Rapid time-resolved immunofluorometric assay for the measurement of creatine kinase in serum and whole blood samples.

A rapid and simple immunochemical method was developed for the assessment of the creatine kinase (MM) isoenzyme [CK(MM)], a protein marker linked with animal welfare and meat quality. The one-step time-resolved immunofluorometric assay produced quantitative results from serum or whole blood samples in 20 min. The analytical limit of detection (mean + 2s) for the immunoassay was 17 ng/mL (n = 6), and the functional limit of detection for the analysis of porcine whole blood samples was 426 ng/mL (n = 24). The working range of the method was linear up to 50 micro g/mL, and the within-assay precision varied between 2.1 and 10.9%. The analysis of porcine serum samples showed that the results from the immunoassay method and colorimetric CK enzyme activity determination were highly correlated (r(2) = 0.965, n = 17, p < 0.001). The practicability of the assay was demonstrated by the analysis of 300 porcine whole blood samples in a slaughterhouse environment.

Animals↗

High-performance real-time quantitative RT-PCR using lanthanide probes and a dual-temperature hybridization assay.

We report a time-resolved fluorescence-based, homogeneous approach for multiplex, real-time or end-point detection of PCR products. Signal generation consists of PCR associated digestion of a 5'-labeled oligonucleotide probe, rapid cooling of the reaction mixture, and hybridization of undigested probe oligonucleotides with a complementary, shorter probe that incorporates a quencher at its 3' end. The signal coming from intact fluorescent probe molecules is, thus, quenched. The fluorophores we have used are environmentally sensitive lanthanide chelates. Their signals can be measured in a time-resolved manner that eliminates most of the unspecific fluorescent background. Signal-to-noise ratios are further enhanced by the environmental sensitivity of these chelates; they exhibit a higher fluorescence intensity when free in solution than when coupled to intact probe molecules. Because of the minimal background fluorescence, the signal-to-noise ratios are higher and threshold cycles are lower than those obtained using conventional TaqMan probes. The multiplexing capacity of the assay chemistry is demonstrated through simultaneous amplification and detection of prostate specific antigen (PSA) cDNA and an internal standard mRNA (mmPSA) using probes labeled with terbium and europium. The applicability of the assay chemistry to routine clinical diagnostics is demonstrated through absolute quantification of PSA mRNA in peripheral blood.

Europium↗

A specificity-enhanced time-resolved fluoroimmunoassay for zeranol employing the dry reagent all-in-one-well principle.

A simple dry chemistry time-resolved fluorescence immunoassay (TR-FIA) method was developed for the measurement of zeranol in bovine urine samples. The samples were purified by immunoaffinity chromatography and a specificity-enhanced zeranol antibody was employed in the immunoassay. This resulted in a highly selective method, which had only negligible reactivity with Fusarium spp. toxins. The all-in-one-well dry chemistry concept made the assay very simple to use because all the assay-specific reagents were already present in the reaction wells in dry form. Only the addition of diluted sample extract was required to perform the competitive one-step TR-FIA and the results were available in less than 1 h. The analytical limit of detection (mean + 3s) for the immunoassay was 0.16 ng ml(-1) (n = 12) and the functional limit of detection for the whole method, estimated by the analysis of zeranol-free samples, was 1.3 ng ml(-1) (n = 20). The recovery of zeranol at the level of 2 ng ml(-1) was 99% (n = 18) and the within-assay variation ranged between 4.5 and 9.0%.

Animals↗

Ultrarapid, ultrasensitive one-step kinetic immunoassay for C-reactive protein (CRP) in whole blood samples: measurement of the entire CRP concentration range with a single sample dilution.

BACKGROUND: Recently, measurement of very low concentrations of C-reactive protein (CRP) has gained popularity as a potential new means for predicting the risk of future cardiac complications. In this study, we demonstrate the feasibility of a kinetic, one-step microparticle assay for quantitative determination of extremely low and high CRP concentrations in the limited timeframe typical for point-of-care testing. METHODS: A noncompetitive, kinetic CRP immunoassay was developed that uses individual, porous microparticles as the solid phase. The microparticles were covalently coated with a monoclonal capture antibody, and the monoclonal detection antibody was labeled with europium. The one-step binding reaction was stopped by washing after 2 min of incubation, and the fluorescence signal of individual particles was measured. RESULTS: The analytical detection limit (mean of zero calibrator + 3 SD) was 0.00016 mg/L CRP. Clinical samples were diluted 400-fold before assay to cover the CRP concentration range of 0.064-1200 mg/L. The assay correlated well with the Dade Behring N High Sensitivity CRP assay (for 0-10 mg/L, r = 0.969, S(y/x) = 0.68, n = 54; for 0-350 mg/L, r = 0.969, S(y/x) = 11.7, n = 100). The within- and between-run CVs based on calculated concentrations were, respectively, 9-16% and 14% at 0.11 mg/L, 4.5-12% and 8.2% at 4.2 mg/L, and 3.5-6.3% and 4.4% at 105 mg/L, with a CV <15% at 0.2 mg/L and above. CONCLUSIONS: Use of the kinetic microparticle approach combined with time-resolved fluorometry allows ultrasensitive quantification of CRP in whole blood in 2 min with a linear assay range spanning more than four orders of magnitude.

Antibodies, Monoclonal↗

Simultaneous quantification of prostate-specific antigen and human glandular kallikrein 2 mRNA in blood samples from patients with prostate cancer and benign disease.

BACKGROUND: Detection or quantification of circulating cancer cells has been proposed as an aid in detection and monitoring of several solid tumors. We investigated the classification accuracy of prostate-specific antigen (PSA) and human glandular kallikrein 2 (hK2) mRNA copy numbers in blood for the differentiation of patients with prostate cancer (PC) and benign disease. METHODS: PSA and hK2 mRNA expression was studied in blood samples from 51 men with PC and 19 men with benign disease. Among the PC patients, 10 had organ-confined disease (pT1-pT2). We used a multiplexed reverse transcription-PCR assay with two highly target-like mRNA internal standards for the simultaneous quantification of PSA and hK2 mRNA. An external calibration curve covered the range of 10(2)-10(6) mRNA copies. RESULTS: PSA and hK2 mRNA were detected in 41 of 51 (median, 1200 copies/0.5 mL of blood) and 43 of 51 (median, 3800 copies/0.5 mL of blood) patients with PC, respectively, whereas only 1 of 19 men with benign disease was positive for both mRNAs (1500 PSA and 3100 hK2 mRNA copies/0.5 mL of blood; P <0.0001, Mann-Whitney U-test). Of the 10 patients with organ-confined PC, only 3 with low Gleason scores (< or =5) were negative for both PSA and hK2 (P = 0.02, Mann-Whitney U-test). CONCLUSIONS: The presence of PC cells in the blood circulation is an early event in PC progression, and quantitative assays for PSA and hK2 mRNA discriminate benign from PC cases. Further studies are needed to determine the diagnostic accuracy and prognostic value of the assays.

Aged↗

A high-capacity streptavidin-coated microtitration plate.

A majority of current immunoassays rely on capturing a specific analyte on a solid phase to allow the separation of the bound analyte from nonbound components. Streptavidin-coated microtitration plates are widely used for immobilization of capturing antibodies, since they provide a generic surface for immobilization of any biotinylated molecule and preserve biomolecule activity much better than direct passive adsorption. Our trials to further improve the properties of the plates resulted in a development of a modified plate, which has higher binding capacity than currently used control plate. The modified coat was prepared by cross-linking streptavidin chemically prior to adsorption onto the microtitration well surfaces. The binding capacities of the plates were measured with biotinylated, europium-labeled molecules and labeled antigen. The immunoassay performance of the plates was studied with noncompetitive, sandwich-type assays of prostate specific antigen (PSA) and human chorionic gonadotropin (hCG). The maximum immobilization capacity of the modified plate was up to 2.5 times higher than that of the control plate. The higher binding capacity was especially emphasized with small-size molecules. The modified high capacity plate increased the linear ranges of the immunoassays and thus delayed the high-dose hook effect. At high antigen concentrations the signal increased up to 59%, and at the conventional linear ranges of the assays, the increase was up to 29%. We conclude that the modified coating method will be valuable for the future miniaturized systems, where high immobilization capacity is needed at limited areas.

Adsorption↗