The biological effectiveness of antiproton irradiation.

BACKGROUND AND PURPOSE: Antiprotons travel through tissue in a manner similar to that for protons until they reach the end of their range where they annihilate and deposit additional energy. This makes them potentially interesting for radiotherapy. The aim of this study was to conduct the first ever measurements of the biological effectiveness of antiprotons. MATERIALS AND METHODS: V79 cells were suspended in a semi-solid matrix and irradiated with 46.7MeV antiprotons, 48MeV protons, or (60)Co gamma-rays. Clonogenic survival was determined as a function of depth along the particle beams. Dose and particle fluence response relationships were constructed from data in the plateau and Bragg peak regions of the beams and used to assess the biological effectiveness. RESULTS: Due to uncertainties in antiproton dosimetry we defined a new term, called the biologically effective dose ratio (BEDR), which compares the response in a minimally spread out Bragg peak (SOBP) to that in the plateau as a function of particle fluence. This value was approximately 3.75 times larger for antiprotons than for protons. This increase arises due to the increased dose deposited in the Bragg peak by annihilation and because this dose has a higher relative biological effectiveness (RBE). CONCLUSION: We have produced the first measurements of the biological consequences of antiproton irradiation. These data substantiate theoretical predictions of the biological effects of antiproton annihilation within the Bragg peak, and suggest antiprotons warrant further investigation.

Animals↗

Dosimetric characteristics of a new linear accelerator under gated operation.

Respiratory gated radiotherapy may allow reduction of the treatment margins, thus sparing healthy tissue and/or allowing dose escalation to the tumor. However, current commissioning and quality assurance of linear accelerators do not include evaluation of gated delivery. The purpose of this study is to test gated photon delivery of a Siemens ONCOR Avant-Garde linear accelerator. Dosimetric characteristics for gated and nongated delivery of 6-MV and 15-MV photons were compared for the range of doses, dose rates, and for several gating regimes. Dose profiles were also compared using Kodak EDR2 and X-Omat V films for 6-MV and 15-MV photons for several dose rates and gating regimes. Results showed that deviation is less than or equal to 0.6% for all dose levels evaluated with the exception of the lowest dose delivered at 25 MU at an unrealistically high gating frequency of 0.5 Hz. At 400 MU, dose profile deviations along the central axes in in-plane and cross-plane directions within 80% of the field size are below 0.7%. No unequivocally detectable dose profile deviation was observed for 50 MU. Based on the comparison with widely accepted standards for conventional delivery, our results indicate that this LINAC is well suited for gated delivery of nondynamic fields.

Artifacts↗

Phase versus amplitude sorting of 4D-CT data.

Image quality of CT scans suffers when objects undergo motion. Respiratory motion causes artifacts, which prevents adequate visualization of anatomy. Four-dimensional CT (4D-CT) is a method in which image reconstruction of moving objects is retrospectively gated according to the recorded phase information of the monitored motion pattern. Although several groups have investigated the use of 4D-CT in radiotherapy, little has been detailed with regard to the sorting method. We present a new retrospective gating technique with sorting based on the amplitude of the motion trace. This method is compared to previously developed methods that sort based on phase. A 16-slice CT scanner (Sensation 16, Siemens Medical Solutions, Erlangen, Germany) was used to acquire images of two phantoms on a motion platform moving in two dimensions. The motion was monitored using a strain gauge inserted inside an adjustable belt. A 180 degrees interpolation was used for reconstruction after gating. Significant improvement using the amplitude-sorting technique was observed, particularly when testing nonperiodic motion functions.

Algorithms↗

Image-guided radiotherapy using a mobile kilovoltage x-ray device.

A mobile isocentric C-arm kilovoltage imager has been evaluated as a potential tool for image-guided radiotherapy. The C-arm is equipped with an amorphous silicon flat panel for high-quality image acquisition. Additionally, the device is capable of cone beam computed tomography (CT) and volumetric reconstruction. This is achieved through the application of a modified Feldkamp algorithm with acquisition over a 180 degrees scan arc. The number of projections can be varied from 100 to 1000, resulting in a reconstructed volume 20 cm in diameter by 15-cm long. While acquisition time depends upon number of projections, acceptable quality images can be obtained in less than 60 seconds. Image resolution and contrast of cone-beam phantom images have been compared with images from a conventional CT scanner. The system has a spatial resolution of > or = 10 lp/cm and resolution is approximately equal in all 3 dimensions. Conversely, subject contrast is poorer than conventional CT, compromised by the increased scatter and underlying noise inherent in cone beam reconstruction, as well as the absence of filtering prior to reconstruction. The mobility of the C-arm makes it necessary to determine the C-arm position relative to the linear accelerator isocenter. Two solutions have been investigated: (1) the use of fiducial markers, embedded in the linac couch, that can subsequently be registered in the image sets; and (2), a navigation approach for infrared tracking of the C-arm relative to the linac isocenter. Observed accuracy in phantom positioning ranged from 1.0 to 1.5 mm using the navigation approach and 1.5 to 2.5 mm using the fiducial-based approach. As part of this work, the impact of respiratory motion on cone-beam image quality was evaluated, and a scheme for retrospective gating was devised. Results demonstrated that kilovoltage cone beam CT provides spatial integrity and resolution comparable to conventional CT. Cone-beam CT studies of patients undergoing radiotherapy have demonstrated acceptable soft tissue contrast, allowing assessment of daily changes in target anatomy. Of the 2 approaches developed to register images to the linac isocenter, the navigation method demonstrated superior accuracy for daily patient positioning relative to the fiducial-based method. Finally, significant image degradation due to respiratory motion was observed. It was demonstrated that this could be improved by correlating the acquisition of individual 2D projections with respiration for retrospective reconstruction of phase-based volumetric datasets.

Humans↗

Stereotactic radiosurgery of the rete mirabile in swine: a longitudinal study of histopathological changes.

OBJECTIVE: Stereotactic radiosurgery is an established, effective treatment for brain arteriovenous malformations. The mechanisms of vessel occlusion in arteriovenous malformations has not been extensively evaluated. To better understand these mechanisms, we report histopathological changes in the swine rete mirabile after stereotactic radiosurgery. METHODS: Thirty-five swine were used, 15 as nonradiated controls and 20 as radiated. Two in the control group and five in the radiated group were sacrificed before the study endpoint. Tissue was obtained from 13 nonradiated (4 at 3 mo, 5 at 6 mo, 4 at 9 mo) and 15 radiated swine (2 at 3 mo, 3 at 6 mo, 10 at 9 mo) for histological, immunohistochemical, and morphometric analysis. RESULTS: Radiated vessels showed increasing intimal hyperplasia over the follow-up period. Histometrical analysis confirmed this with evidence of progressive luminal narrowing over the follow-up period. Immunohistochemical analysis showed intimal cells to be proliferating smooth muscle cells with surrounding extracellular collagen Type IV. Adventitial fibrosis composed of collagen Type IV was also seen with smooth muscle cells interspersed within the collagen matrix. The nonradiated animals showed no intimal hyperplasia or change in the appearance or size of the vessels over the same follow-up period. Adventitial fibrosis was minimal in the nonradiated animals. CONCLUSION: The vessels show an intimal response to radiation with progressive occlusion caused by migrating, proliferating smooth muscle cells, a likely source of the extracellular collagen in the intima. Cytokine mediated pathways likely produce these morphological changes. Future studies will be directed toward elucidating these underlying molecular mechanisms.

Animals↗

Optimization of multi-slice helical respiration-correlated CT: the effects of table speed and rotation time.

While respiration-correlated CT is gaining acceptance in clinical radiotherapy, the effect of scanning parameters on the image quality has yet to be addressed. The intent of this study was to characterize the effects of gantry rotation and table speed on various image quality characteristics in multi-slice, helical, retrospectively-gated CT images. Images of stationary and moving phantoms were obtained in helical mode on a 20-slice CT scanner. Motion was generated by a computer-controlled platform capable of moving simultaneously in two dimensions. Motion was monitored using a pressure gauge inserted inside an adjustable belt. Selected scans were retrospectively gated into ten phases based on the monitored motion. Gantry rotation speeds of 0.5 s and 1.0 s were evaluated with pitches ranging from 0.1 to 0.45. Several parameters, including calculated object volumes, trajectory (movement from peak to trough), deformation (actual volume divided by volume created with the maximum diameter of contoured object) and z-axis resolution, were used to characterize image quality. These studies indicate that for objects in the peak phase of a movement pattern that simulates breathing, retrospectively gated scans using fast gantry rotation speeds produce volume, trajectory, deformation and z-axis resolution results comparable with those of a stationary object.

Algorithms↗

Targeting accuracy of an image guided gating system for stereotactic body radiotherapy.

Recently, a commercial system capable of x-ray image guided patient positioning and respiratory gated delivery has become available. Here we describe the operational principles of this system and investigate its geometric targeting accuracy under controlled conditions. The system tracks breathing via infrared (IR) detection of reflective markers located on the patient's abdomen. Localization kilovoltage (kV) x-rays are triggered from within the gated delivery window portion of the breathing trace and after positioning, the tumour will cross the linac isocentre during gated delivery. We tested geometric accuracy of this system by localizing and delivering gated fields to a moving phantom. Effects of phantom speed, gating window location, timing errors and phantom rotations on positioning and gating accuracy were investigated. The system delivered gated fields to both a moving and static phantom with equal accuracy. The position of the gating window affects accuracy only to the extent that an asymmetric breathing motion could affect dose distribution within its boundaries. Positioning errors were found to be less then 0.5 +/- 0.2 mm for phantom rotations up to 5 degrees. We found and corrected a synchronization error caused by a faulty x-ray duration setting and detected a 60 +/- 20 ms time delay in our linear accelerator.

Calibration↗

Respiratory correlated cone-beam computed tomography on an isocentric C-arm.

A methodology for 3D image reconstruction from retrospectively gated cone-beam CT projection data has been developed. A mobile x-ray cone-beam device consisting of an isocentric C-arm equipped with a flat panel detector was used to image a moving phantom. Frames for reconstruction were retrospectively selected from complete datasets based on the known rotation of the C-arm and a signal from a respiratory monitor. Different sizes of gating windows were tested. A numerical criterion for blur on the reconstructed image was suggested. The criterion is based on minimization of an Ising energy function, similar to approaches used in image segmentation or restoration. It is shown that this criterion can be used for the determination of the optimal gating window size. Images reconstructed from the retrospectively gated projection sequences using the optimal gating window data showed a significant improvement compared to images reconstructed from the complete projection datasets.

Equipment Design↗

Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group no. 68.

Intracranial stereotactic positioning systems (ISPSs) are used to position patients prior to precise radiation treatment of localized lesions of the brain. Often, the lesion is located in close proximity to critical anatomic features whose functions should be maintained. Many types of ISPSs have been described in the literature and are commercially available. These are briefly reviewed. ISPS systems provide two critical functions. The first is to establish a coordinate system upon which a guided therapy can be applied. The second is to provide a method to reapply the coordinate system to the patient such that the coordinates assigned to the patient's anatomy are identical from application to application. Without limiting this study to any particular approach to ISPSs, this report introduces nomenclature and suggests performance tests to quantify both the stability of the ISPS to map diagnostic data to a coordinate system, as well as the ISPS's ability to be realigned to the patient's anatomy. For users who desire to develop a new ISPS system, it may be necessary for the clinical team to establish the accuracy and precision of each of these functions. For commercially available systems that have demonstrated an acceptable level of accuracy and precision, the clinical team may need to demonstrate local ability to apply the system in a manner consistent with that employed during the published testing. The level of accuracy and precision required of an individual ISPS system is dependent upon the clinical protocol (e.g., fractionation, margin, pathology, etc.). Each clinical team should provide routine quality assurance procedures that are sufficient to support the assumptions of accuracy and precision used during the planning process. The testing of ISPS systems can be grouped into two broad categories, type testing, which occurs prior to general commercialization, and site testing, performed when a commercial system is installed at a clinic. Guidelines to help select the appropriate tests as well as recommendations to help establish the required frequency of testing are provided. Because of the broad scope of different systems, it is important that both the manufacturer and user rigorously critique the system and set QA tests appropriate to the particular device and its possible weaknesses. Major recommendations of the Task Group include: introduction of a new nomenclature for reporting repositioning accuracy; comprehensive analysis of patient characteristics that might adversely affect positioning accuracy; performance of testing immediately before each treatment to establish that there are no gross positioning errors; a general request to the Medical Physics community for improved QA tools; implementation of weekly portal imaging (perhaps cone beam CT in the future) as a method of tracking fractionated patients (as per TG 40); and periodic routine reviews of positioning accuracy.

Equipment Failure Analysis↗

Three-dimensional fast imaging employing steady-state acquisition magnetic resonance imaging for stereotactic radiosurgery of trigeminal neuralgia.

OBJECTIVE: The aim of this study was to demonstrate the use and applications of the three-dimensional fast imaging employing steady-state acquisition (3-D-FIESTA) magnetic resonance imaging sequence in targeting and planning for stereotactic radiosurgery of trigeminal neuralgia. METHODS: A 3-D-FIESTA sequence for visualization of cranial nerves in the cranial base was added to the routine magnetic resonance imaging scan to enhance the treatment planning for trigeminal neuralgia. T1-weighted images, 1 mm thick, were directly compared with the FIESTA sequence for the exact visualization of the trigeminal entry zone and surrounding vasculature. The target accuracy was evaluated by image fusion of computed tomographic and magnetic resonance imaging scans. The anatomy visualized with the FIESTA sequence was validated by direct inspection of the gross anatomic specimens of the trigeminal complex. RESULTS: A total of 15 consecutive patients, 10 women and 5 men, underwent radiosurgery for essential trigeminal neuralgia between April and July, 2003. The mean age of the patients was 65.2 years (range, 24-83 yr). Nine patients had right-sided symptoms. Four patients had had previous surgery (two microvascular decompression, one percutaneous rhizotomy, and one radiofrequency thermocoagulation). The 3-D-FIESTA sequence successfully demonstrated the trigeminal complex (root entry zone, trigeminal ganglion, rootlets, and vasculature) in 14 patients (93.33%). The 3-D-FIESTA sequence also allowed visualization of the branches of the trigeminal nerve inside Meckel's cavity. This exact visualization correlated precisely with the anatomic specimens. In one patient (6.66%), it was not possible to demonstrate the related vasculature. However, the other structures were clearly visualized. CONCLUSION: The 3-D-FIESTA sequence is used in this study for demonstration of the exact anatomy of the trigeminal complex for the purpose of radiosurgical planning and treatment of trigeminal neuralgia. With such imaging techniques, radiosurgical targeting of specific trigeminal nerve branches may be feasible. It has not been possible previously to target individual branches of the trigeminal nerve.

Adult↗

Degeneracy, frequency response and filtering in IMRT optimization.

This paper attempts to provide an answer to some questions that remain either poorly understood, or not well documented in the literature, on basic issues related to intensity modulated radiation therapy (IMRT). The questions examined are: the relationship between degeneracy and frequency response of optimizations, effects of initial beamlet fluence assignment and stopping point, what does filtering of an optimized beamlet map actually do and how could image analysis help to obtain better optimizations? Two target functions are studied, a quadratic cost function and the log likelihood function of the dynamically penalized likelihood (DPL) algorithm. The algorithms used are the conjugate gradient, the stochastic adaptive simulated annealing and the DPL. One simple phantom is used to show the development of the analysis tools used and two clinical cases of medium and large dose matrix size (a meningioma and a prostate) are studied in detail. The conclusions reached are that the high number of iterations that is needed to avoid degeneracy is not warranted in clinical practice, as the quality of the optimizations, as judged by the DVHs and dose distributions obtained, does not improve significantly after a certain point. It is also shown that the optimum initial beamlet fluence assignment for analytical iterative algorithms is a uniform distribution, but such an assignment does not help a stochastic method of optimization. Stopping points for the studied algorithms are discussed and the deterioration of DVH characteristics with filtering is shown to be partially recoverable by the use of space-variant filtering techniques.

Algorithms↗

Stereotactic radiotherapy for treatment of cavernous sinus meningiomas.

PURPOSE: To assess the safety and efficacy of stereotactic radiotherapy (SRT) using a linear accelerator equipped with a micromultileaf collimator for cavernous sinus meningiomas. METHODS AND MATERIALS: Forty-five patients with benign cavernous sinus meningiomas were treated with SRT between November 1997 and April 2002. Sixteen patients received definitive treatment on the basis of imaging characteristics of the cavernous sinus tumor. Twenty-nine patients received SRT either as immediate adjuvant treatment after incomplete resection or at documented recurrence. Treatment planning in all patients included CT-MRI image fusion and beam shaping using a micromultileaf collimator. The primary tumor volume varied from 1.41 to 65.66 cm(3) (median, 14.5 cm(3)). The tumor diameter varied from 1.4 to 7.4 cm (median, 3.8 cm). Tumor compressed the optic chiasm or optic nerve in 30 patients. All tumors were treated with a single isocenter plus a margin of normal parenchyma varying from 1 to 5 mm (median, 2.5 mm). The prescribed dose varied from 4250 to 5400 cGy (median, 5040 cGy). The prescription isodose varied from 87% to 95% (median, 90%). The maximal tumor dose varied from 5000 to 6000 cGy (median, 5600 cGy). The follow-up varied from 12 to 53 months (median, 36 months). RESULTS: The actuarial 3-year overall and progression-free survival rate was 100% and 97.4%, respectively. One patient (2%) developed local relapsed at 18 months. A partial imaging response occurred in 18% of patients, and the tumor was stable in the remaining 80%. Preexisting neurologic complaints improved in 20% of patients and were stable in the remainder. No patient, tumor, or treatment factors were found to be predictive of imaging or clinical response. Transient acute morbidities included headache responsive to nonnarcotic analgesics in 4 patients, fatigue in 3 patients, and retroorbital pain in 1 patient. No treatment-induced peritumoral edema, cranial neuropathy, endocrine dysfunction, cognitive decline, or second malignancy occurred. One patient had an ipsilateral cerebrovascular accident 6 months after SRT. CONCLUSION: Stereotactic radiotherapy is both safe and effective for patients with cavernous sinus meningiomas. Field shaping using a micromultileaf collimator allows conformal and homogeneous radiation of cavernous sinus meningiomas that may not be amenable to single-fraction stereotactic radiosurgery because of tumor size or location. Additional clinical experience is necessary to determine the position of SRT among the available innovative fractionated RT options for challenging skull base meningiomas.

Adult↗

A methodology for verification of radiotherapy dose calculation.

OBJECT: A methodology for dosimetric verification of radiation therapy plans was developed and implemented. Dosimetric accuracy of clinically active intensity-modulated radiotherapy (IMRT) and intensity-modulated radiosurgery (IMRS) programs was assessed using this methodology. METHODS: The methodology included several dosimetric tasks that were performed to assess the dosimetric accuracy of a treatment plan. Absolute dosimetry of the composite plan was performed using an ionization chamber. Film dosimetry was performed for each individual field and for the multifield composite plan. Calculated dose distributions and film measurements were compared using software developed for the specific tasks. Two-dimensional maps of gamma index, dose difference, and distance-to-agreement were calculated and displayed. To date, good agreement between measurements and calculations has been observed in 160 clinical IMRT and IMRS plans. The largest observed absolute dose disagreement was -4.79%. The mean absolute dose difference was 0.26%, with a standard deviation of 1.75%. The authors specify a 3% dose difference and 3-mm distance as the scaling acceptability criteria for the gamma index calculations of the film measurement analysis. The planning and delivery system in clinical use has proven consistently to satisfy these criteria. CONCLUSIONS: The dosimetric verification methods and the software tools developed were both quantitative and clinically practical. The measurements and the analysis demonstrated that the IMRT and IMRS planning and delivery system in use was sufficiently accurate for highly conformal treatments.

Film Dosimetry↗

Stereotactic radiotherapy for the treatment of acoustic neuromas.

OBJECT: The authors sought to assess the safety and efficacy of stereotactic radiotherapy when using a linear accelerator equipped with a micromultileaf collimator for the treatment of patients with acoustic neuromas. METHODS: Fifty patients harboring acoustic neuromas were treated with stereotactic radiotherapy between September 1997 and June 2003. Two patients were lost to follow-up review. Patient age ranged from 20 to 76 years (median 59 years), and none had neurofibromatosis. Forty-two patients had useful hearing prior to stereotactic radiotherapy. The fifth and seventh cranial nerve functions were normal in 44 and 46 patients, respectively. Tumor volume ranged from 0.3 to 19.25 ml (median 2.51 ml). The largest tumor dimension varied from 0.6 to 4 cm (median 2.2 cm). Treatment planning in all patients included computerized tomography and magnetic resonance image fusion and beam shaping by using a micromultileaf collimator. The planning target volume included the contrast-enhancing tumor mass and a margin of normal tissue varying from 1 to 3 mm (median 2 mm). All tumors were treated with 6-MV photons and received 54 Gy prescribed at the 90% isodose line encompassing the planning target volume. A sustained increase greater than 2 mm in any tumor dimension was defined as local relapse. The follow-up duration varied from 6 to 74 months (median 36 months). The local tumor control rate in the 48 patients available for follow up was 100%. Central tumor hypodensity occurred in 32 patients (67%) at a median of 6 months following stereotactic radiotherapy. In 12 patients (25%), tumor size increased 1 to 2 mm at a median of 6 months following stereotactic radiotherapy. Increased tumor size in six of these patients was transient. In 13 patients (27%), tumor size decreased 1 to 14 mm at a median of 6 months after treatment. Useful hearing was preserved in 39 patients (93%). New facial numbness occurred in one patient (2.2%) with normal fifth cranial nerve function prior to stereotactic radiotherapy. New facial palsy occurred in one patient (2.1 %) with normal seventh cranial nerve function prior to treatment. No patient's pretreatment dysfunction of the fifth or seventh cranial nerve worsened after stereotactic radiotherapy. Tinnitus improved in six patients and worsened in two. CONCLUSIONS: Stereotactic radiotherapy using field shaping for the treatment of acoustic neuromas achieves high rates of tumor control and preservation of useful hearing. The technique produces low rates of damage to the fifth and seventh cranial nerves. Long-term follow-up studies are necessary to confirm these findings.

Actuarial Analysis↗

Functional stereotactic radiosurgery involving a dedicated linear accelerator and gamma unit: a comparison study.

OBJECT: The purpose of this work was to investigate the targeting and dosimetric characteristics of a linear accelerator (LINAC) system dedicated for stereotactic radiosurgery compared with those of a commercial gamma knife (GK) unit. METHODS: A phantom was rigidly affixed within a Leksell stereotactic frame and axial computerized tomography scans were obtained using an appropriate stereotactic localization device. Treatment plans were performed, film was inserted into a recessed area, and the phantom was positioned and treated according to each treatment plan. In the case of the LINAC system, four 140 degrees arcs, spanning +/-60 degrees of couch rotation, were used. In the case of the GK unit, all 201 sources were left unplugged. Radiation was delivered using 3- and 8-mm LINAC collimators and 4- and 8-mm collimators of the GK unit. Targeting ability was investigated independently on the dedicated LINAC by using a primate model. Measured 50% spot widths for multisource, single-shot radiation exceeded nominal values in all cases by 38 to 70% for the GK unit and 11 to 33% for the LINAC system. Measured offsets were indicative of submillimeter targeting precision on both devices. In primate studies, the appearance of an magnetic resonance imaging-enhancing lesion coincided with the intended target. CONCLUSIONS: Radiosurgery performed using the 3-mm collimator of the dedicated LINAC exhibited characteristics that compared favorably with those of a dedicated GK unit. Overall targeting accuracy in the submillimeter range can be achieved, and dose distributions with sharp falloff can be expected for both devices.

Film Dosimetry↗

A feasibility study of 18F-fluorodeoxyglucose positron emission tomography targeting and simultaneous integrated boost for intensity-modulated radiosurgery and radiotherapy.

OBJECT: The authors hypothesized that the efficacy of intensity-modulated radiation therapy (IMRT) can be enhanced by selectively increasing the radiation dose to the biologically active positron emission tomography (PET)-documented positive tumor subregions while simultaneously maintaining the overall clinically established target dose. METHODS: The authors undertook a feasibility study to evaluate IMRT PET/computerized tomography (CT) protocol for boost treatment in selected cancer patients. Prior to treatment, FDG-PET and CT scans were acquired using an integrated PET/CT scanner, ensuring accurate correlation between image sets. After acquisition, tumor volume and objects-at-risk (OARs) were outlined on the CT scans; any PET-positive tumor subregions were similarly outlined. Daily dosages of 1.8 to 2 Gy were prescribed to tumor volume and the margin whereas additional dosages of 10 to 20% were delivered to PET-positive subregions. Dosage-volume histogram-derived constraints were used in inverse planning to specify the desired dose to one or more PET-positive tumor subregions, CT-delineated tumor volume, and OARs. The IMRT treatment was delivered using a micromultileaf collimator. Simultaneous integrated boost radiation was successfully delivered using IMRT with PET/CT planning. Excellent dose conformality was achieved in the tumor volume and the dose to PET-positive tumor subregions was increased while minimizing the dose to OARs. CONCLUSIONS: When coupled with IMRT, PET/CT scanning allows dose escalation to biologically active subregions within the tumor volume. Further study is needed to determine if dose escalation to FDG-PET-active sites correlates with improved treatment outcome. Finally, in extracranial sites, PET scanning should only be performed with a dedicated PET/CT device because present image fusion technologies are inadequate for accurately registering deformable objects.

Brain Neoplasms↗

Absence of multiple local minima effects in intensity modulated optimization with dose-volume constraints.

This paper reports on the analysis of intensity modulated radiation treatment optimization problems in the presence of non-convex feasible parameter spaces caused by the specification of dose-volume constraints for the organs-at-risk (OARs). The main aim was to determine whether the presence of those non-convex spaces affects the optimization of clinical cases in any significant way. This was done in two phases: (1) Using a carefully designed two-dimensional mathematical phantom that exhibits two controllable minima and with randomly initialized beamlet weights, we developed a methodology for exploring the nature of the convergence characteristics of quadratic cost function optimizations (deterministic or stochastic). The methodology is based on observing the statistical behaviour of the residual cost at the end of optimizations in which the stopping criterion is progressively more demanding and carrying out those optimizations to very small error changes per iteration. (2) Seven clinical cases were then analysed with dose-volume constraints that are stronger than originally used in the clinic. The clinical cases are two prostate cases differently posed, a meningioma case, two head-and-neck cases, a spleen case and a spine case. Of the 14 different sets of optimizations (with and without the specification of maximum doses allowed for the OARs), 12 fail to show any effect due to the existence of non-convex feasible spaces. The remaining two sets of optimizations show evidence of multiple minima in the solutions, but those minima are very close to each other in cost and the resulting treatment plans are practically identical, as measured by the quality of the dose-volume histograms (DVHs). We discuss the differences between fluence maps resulting from those similar treatment plans. We provide a possible reason for the observed results and conclude that, although the study is necessarily limited, the annealing characteristics of a simulated annealing method may not be justified in clinical optimization in the presence of dose-volume constraints. The results of optimizations by the Newton gradient (NG) method with a quadratic cost function are reported in detail. An adaptive simulated annealing method, optimizing the same function, and the dynamically penalized likelihood method, optimizing a log likelihood function, have also been used in the study. The results of the latter two methods have only been discussed briefly, as they yielded the same conclusions as the NG method.

Algorithms↗

The effects of tumor motion on planning and delivery of respiratory-gated IMRT.

The purpose of this study is to investigate the effects of object motion on the planning and delivery of IMRT. Two phantoms containing objects were imaged using CT under a variety of motion conditions. The effects of object motion on axial CT acquisition with and without gating were assessed qualitatively and quantitatively. Measurements of effective slice width and position for the CT scans were made. Mutual information image fusion was adapted for use as a quantitative measure of object deformation in CT images. IMRT plans were generated on the CT scans of the moving and gated object images. These plans were delivered with motion, with and without gating, and the delivery error between the moving deliveries and a nonmoving delivery was assessed using a scalable vector-based index. Motion during CT acquisition produces motion artifact, object deformation, and object mispositioning, which can be substantially reduced with gating. Objects that vary in cross section in the direction of motion exhibit the most deformation in CT images. Mutual information provides a useful quantitative estimate of object deformation. The delivery of IMRT in the presence of target motion significantly alters the delivered dose distribution in relation to the planned distribution. The utilization of gating for IMRT treatment, including imaging, planning, and delivery, significantly reduces the errors introduced by object motion.

Artifacts↗