PubMed Health⌕ Search

Biomedical subjects

Timothy G Townsend

Publications and source records attributed to Timothy G Townsend.

17 recordsLinked to original sources

A mass balance approach for evaluating leachable arsenic and chromium from an in-service CCA-treated wood structure.

Many existing residential wood structures, such as playsets and decks, have been treated with chromated copper arsenate (CCA). This preservative chemical can be released from these structures incrementally over time through contact with rainfall. The objective of this study was to evaluate the levels of arsenic and chromium leached from an in-service CCA-treated deck exposed to rainfall, as well as their possible impacts on soils and shallow groundwater. Two monitoring stations, one containing a CCA-treated deck and the other containing an untreated deck as a control, were constructed outside for this study. Rainfall, runoff water from the decks, soils below the decks, and infiltrated water through 0.7-m depth of soil were monitored for arsenic and chromium over a period of 3 years. The concentration of the CCA-treated deck runoff for arsenic (0.114-4.66 mg/L) and chromium (0.008-0.470 mg/L) were significantly (p<0.001) higher than the untreated deck runoff (< or =0.002 mg/L for both). During the 3-year monitoring period, 13% of the arsenic and 1.4% of the chromium were leached from the amount initially present in the CCA-treated wood. Arsenic levels (<0.1-46 mg/kg) in soils under the CCA-treated deck were significantly (p<0.001) higher than under the untreated deck (<0.1-2.7 mg/kg), while chromium levels were statistically the same below the two decks (2.4-9.6 mg/kg). Approximately 94% of the arsenic from the runoff was absorbed in the soils below the CCA-treated deck; the upper 2.5 cm of the soils captured 42% of the total. The infiltrated water concentrations for arsenic (<0.001-0.085 mg/L) and chromium (<0.001-0.010 mg/L) below the CCA-treated deck were both significantly (p<0.001) higher than below the untreated deck (< or =0.006 mg/L). The amounts of arsenic found in the infiltrated water below the CCA-treated deck represented 6% of total arsenic leached and less than 0.7% of the initial mass in the wood. The study demonstrated that exposure of a CCA-treated deck to rainfall resulted in elevated arsenic concentrations in both runoff and soil. Although only a relatively small fraction of the initial arsenic from the wood was found to infiltrate through the soil, these impacts were significant and caused the infiltrated water to exceed drinking water standards. The study suggests that potential exposures to arsenic exist indirectly through an environment that is contaminated with arsenic leached from in-service CCA-treated wood.

Architecture↗

Arsenic leaching from mulch made from recycled construction and demolition wood and impacts of iron-oxide colorants.

Mulch made from recycled construction and demolition (C&D) wood has been reported to contain elevated levels of arsenic from inadvertent inclusion of chromated copper arsenate (CCA)-treated wood. Such mulch is also commonly colored with iron oxide, a compound known to bind arsenic. The objectives of this study were to quantify the releases of arsenic from mulch made from C&D wood, to evaluate the impacts of an iron-oxide colorant in potentially decreasing arsenic leaching rates, and to evaluate the relative significance of additional variables on leachate concentrations. Atotal of 3 sets of mulch samples (0%, 5%, or 100% CCA-treated wood) were prepared containing a sample either with or without colorant addition. Each sample was subjected to two tests: a field leaching test and the Synthetic Precipitation Leaching Procedure (SPLP). Results showed that arsenic concentrations in the field leachate from the 0% treated wood mulches were consistently low (<0.003-0.013 mg/L) whereas leachates from 5 and 100% treated wood mulches were characterized by higher arsenic concentrations (0.059-2.23 mg/L for 5%; 0.711-22.7 mg/L for 100%). The mass of arsenic leached from the field samples during the 1-year monitoring period was between 10 and 15% of the initial mass of arsenic. The colorant reduced the leaching of arsenic by more than 20% for the field leachate and 50% for the SPLP leachate, on average. However, the study showed that the effect may not last for long periods. Besides colorant addition other factors were observed to affect the amount of arsenic leached from contaminated mulch. These include the proportion of CCA-treated wood in the mulch, time, and pH of rainfall.

Arsenates↗

Review of state of the art methods for measuring water in landfills.

In recent years several types of sensors and measurement techniques have been developed for measuring the moisture content, water saturation, or the volumetric water content of landfilled wastes. In this work, we review several of the most promising techniques. The basic principles behind each technique are discussed and field applications of the techniques are presented, including cost estimates. For several sensors, previously unpublished data are given. Neutron probes, electrical resistivity (impedance) sensors, time domain reflectometry (TDR) sensors, and the partitioning gas tracer technique (PGTT) were field tested with results compared to gravimetric measurements or estimates of the volumetric water content or moisture content. Neutron probes were not able to accurately measure the volumetric water content, but could track changes in moisture conditions. Electrical resistivity and TDR sensors tended to provide biased estimates, with instrument-determined moisture contents larger than independent estimates. While the PGTT resulted in relatively accurate measurements, electrical resistivity and TDR sensors provide more rapid results and are better suited for tracking infiltration fronts. Fiber optic sensors and electrical resistivity tomography hold promise for measuring water distributions in situ, particularly during infiltration events, but have not been tested with independent measurements to quantify their accuracy. Additional work is recommended to advance the development of some of these instruments and to acquire an improved understanding of liquid movement in landfills by application of the most promising techniques in the field.

Refuse Disposal↗

RCRA toxicity characterization of discarded electronic devices.

The potential for discarded electronic devices to be classified as toxicity characteristic (TC) hazardous waste under provisions of the Resource Conservation and Recovery Act (RCRA) using the toxicity characteristic leaching procedure (TCLP) was examined. The regulatory TCLP method and two modified TCLP methods (in which devices were disassembled and leached in or near entirety) were utilized. Lead was the only element found to leach at concentrations greater than its TC limit (5 mg/L). Thirteen different types of electronic devices were tested using either the standard TCLP or modified versions. Every device type leached lead above 5 mg/L in at least one test and most devices leached lead above the TC limit in a majority of cases. Smaller devices that contained larger amounts of plastic and smaller amounts of ferrous metal (e.g., cellular phones, remote controls) tended to leach lead above the TC limit at a greater frequency than devices with more ferrous metal (e.g., computer CPUs, printers).

Cell Phone↗

Hydrogen sulfide flux measurements from construction and demolition debris (C&D) landfills.

Hydrogen sulfide (H2S) has been identified as a principal odorous component of gaseous emissions from construction and demolition debris (C&D) landfills. Although several studies have reported the ambient concentrations of H2S near C&D landfills, few studies have quantified emission rates of H2S. One of the most widely used techniques for measuring surface gas emission rates from landfills is the flux chamber method. Flux measurements using the flux chamber were performed at five different C&D landfills from April to August, 2003. The flux rates of H2S measured in this research were between 0.192 and 1.76 mg/(m2-d).

Air Pollutants↗

Release of arsenic to the environment from CCA-treated wood. 1. Leaching and speciation during service.

Insufficient information exists about the speciation of arsenic leaching from in-service chromated copper arsenate (CCA)-treated products and the overall impact to soils and groundwater. To address this issue, two decks were constructed, one from CCA-treated wood and the other from untreated wood. Both decks were placed in the open environment where they were impacted by rainfall. Over a one-year period, rainwater runoff from the decks and rainwater infiltrating through 0.7 m of sand below the decks was collected and analyzed for arsenic species by HPLC-ICP-MS. The average arsenic concentration in the runoff of the untreated deck was 2-3 microg/L, whereas from the CCA-treated deck it was 600 microg/L. Both inorganic As(III) and As(V) were detected in the runoff from both decks, with inorganic As(V) predominating. No detectable levels of organoarsenic species were observed. The total arsenic concentration in the infiltrated water of the treated deck had risen from a background concentration of 3 microg/L to a concentration of 18 microg/L at the end of the study. Data from the deck study were combined with annual CCA-treated wood production statistics to develop a mass balance model to estimate the extent of arsenic leaching from in-service CCA-treated wood structures to Florida soils. Results showed that during the year 2000, of the 28 000 t of arsenic imported into the state and utilized for in-service CCA-treated wood products, approximately 4600 t had already leached. Future projections suggest that an additional 11,000 t of arsenic will leach during in-service use within the next 40 years.

Arsenates↗

Release of arsenic to the environment from CCA-treated wood. 2. Leaching and speciation during disposal.

Wood treated with chromated copper arsenate (CCA) is primarily disposed within construction and demolition (C&D) debris landfills, with wood monofills and municipal solid waste (MSW) landfills as alternative disposal options. This study evaluated the extent and speciation of arsenic leaching from landfills containing CCA-treated wood. In control lysimeters where untreated wood was used, dimethylarsinic acid (DMAA) represented the major arsenic species. The dominant arsenic species differed in the lysimeters containing CCA-treated wood, with As(V) greatest in the monofill and C&D lysimeters and As(III) greatest in the MSW lysimeters. In CCA-containing lysimeters, the organoarsenic species monomethylarsonic acid (MMAA) and DMAAwere virtually absent in the monofill lysimeter and observed in the C&D and MSW lysimeters. Overall arsenic leaching rate varied for the wood monofill (0.69% per meter of water added), C&D (0.36% per m), and MSW (0.84% per m) lysimeters. Utilizing these rates with annual disposal data, a mathematical model was developed to quantify arsenic leaching from CCA-treated wood disposed to Florida landfills. Model findings showed between 20 and 50 t of arsenic (depending on lysimeter type) had leached prior to 2000 with an expected increase between 350 and 830 t by 2040. Groundwater analysis from 21 Florida C&D landfills suspected of accepting CCA-treated wood showed that groundwater at 3 landfills was characterized by elevated arsenic concentrations with only 1 showing impacts from the C&D waste. The slow release of arsenic from disposed treated wood may account for the lack of significant impact to groundwater near most C&D facilities at this time. However, greater impacts are anticipated in the future given that the maximum releases of arsenic are expected by the year 2100.

Arsenates↗

Reduced sulfur compounds in gas from construction and demolition debris landfills.

The biological conversion of sulfate from disposed gypsum drywall to hydrogen sulfide (H(2)S) in the anaerobic environment of a landfill results in odor problems and possible health concerns at many disposal facilities. To examine the extent and magnitude of such emissions, landfill gas samples from wells, soil vapor samples from the interface of the waste and cover soil, and ambient air samples, were collected from 10 construction and demolition (C&D) debris landfills in Florida and analyzed for H(2)S and other reduced sulfur compounds (RSC). H(2)S was detected in the well gas and soil vapor at all 10 sites. The concentrations in the ambient air above the surface of the landfill were much lower than those observed in the soil vapor, and no direct correlation was observed between the two sampling locations. Methyl mercaptan and carbonyl sulfide were the most frequently observed other RSC, though they occurred at smaller concentrations than H(2)S. This research confirmed the presence of H(2)S at C&D debris landfills. High concentrations of H(2)S may be a concern for employees working on the landfill site. These results indicate that workers should use proper personal protection at C&D debris landfills when involved in excavation, landfill gas collection, or confined spaces. The results indicate that H(2)S is sufficiently diluted in the atmosphere to not commonly pose acute health impacts for these landfill workers in normal working conditions. H(2)S concentrations were extremely variable with measurements occurring over a very large range (from less than 3 ppbv to 12,000 ppmv in the soil vapor and from less than 3 ppbv to 50 ppmv in ambient air). Possible reasons for the large intra- and inter-site variability observed include waste and soil heterogeneities, impact of weather conditions, and different site management practices.

Air Pollutants↗

Hydrogen sulfide generation in simulated construction and demolition debris landfills: impact of waste composition.

Hydrogen sulfide (H2S) generation in construction and demolition (C&D) debris landfills has been associated with the biodegradation of gypsum drywall. Laboratory research was conducted to observe H2S generation when drywall was codisposed with different C&D debris constituents. Two experiments were conducted using simulated landfill columns. Experiment 1 consisted of various combinations of drywall, wood, and concrete to determine the impact of different waste constituents and combinations on H2S generation. Experiment 2 was designed to examine the effect of concrete on H2S generation and migration. The results indicate that decaying drywall, even alone, leached enough sulfate ions and organic matter for sulfate-reducing bacteria (SRB) to generate large H2S concentrations as high as 63,000 ppmv. The codisposed wastes show some effect on H2S generation. At the end of experiment 1, the wood/drywall and drywall alone columns possessed H2S concentrations > 40,000 ppmv. Conversely, H2S concentrations were < 1 ppmv in those columns containing concrete. Concrete plays a role in decreasing H2S by increasing pH out of the range for SRB growth and by reacting with H2S. This study also showed that wood lowered H2S concentrations initially by decreasing leachate pH values. Based on the results, two possible control mechanisms to mitigate H2S generation in C&D debris landfills are suggested.

Air Pollutants, Occupational↗

Factors affecting TCLP lead leachability from computer CPUs.

The factors impacting lead leachability from computer central processing units (CPUs) during the toxicity characteristic leaching procedure (TCLP) were investigated. Several CPUs were disassembled and their component materials were decreased in size to meet the requirements of the TCLP. The impact of CPU composition was examined by leaching different combinations of the CPU components. The ferrous metal content of the mixture greatly impacted lead leaching. TCLP lead concentrations of CPUs predicted by leaching the lead-bearing printed wire boards alone were much greater than those measured when the ferrous metal of the CPU was included in the mixture. The leaching of iron and zinc from the galvanized steel components of the CPU created electrochemical conditions where lead was less soluble. Additional size reduction beyond that required by the TCLP did not result in additional lead leaching. As the volume of head space above the leaching solution increased, the concentration of lead measured increased as well.

Acetic Acid↗

Heavy metal content in soil reclaimed from a municipal solid waste landfill.

Residues reclaimed from a municipal solid waste (MSW) landfill were characterized for the concentrations of a number of heavy metals. The residue fractions analyzed included a fine fraction (<0.425 mm), an intermediate fraction (>0.425 and <6.3 mm) and a fraction consisting of paper products that could ultimately degrade to a smaller size. The intermediate fraction appeared to be organic in nature, while the fine fraction was more soil-like. In general, the metal concentrations were greatest in the intermediate fraction and lowest in the fine fraction. The effect of sample age on the elemental content was also investigated. The concentrations of several elements were greater in older samples (sample approximately 8 years in age) when compared to newer samples (sample approximately 3 years in age). Limitations associated with the land application of residual soil (composed of the fine and intermediate fractions) were assessed by comparing measured concentrations to regulatory threshold values. In general, most metal concentrations were below regulatory thresholds for use in unrestricted settings. At the concentrations measured, however, several elements might limit reuse options, depending on which regulatory threshold serves as a benchmark. Elevated concentrations of arsenic presented the greatest limitation with respect to common US thresholds while elevated cadmium concentrations presented the greatest limitation when compared to UK thresholds. The source of the arsenic was determined to be the waste, not the cover soil.

Environmental Monitoring↗

Arsenic speciation of solvent-extracted leachate from new and weathered CCA-treated wood.

For the past 60 yr, chromate-copper-arsenate (CCA) has been used to pressure-treat millions of cubic meters of wood in the United States for the construction of many outdoor structures. Leaching of arsenic from these structures is a possible health concern as there exists the potential for soil and groundwater contamination. While previous studies have focused on total arsenic concentrations leaching from CCA-treated wood, information pertaining to the speciation of arsenic leached is limited. Since arsenic toxicity is dependent upon speciation, the objective of this study was to identify and quantify arsenic species leaching from new and weathered CCA-treated wood and CCA-treated wood ash. Solvent-extraction experiments were carried out by subjecting the treated wood and the ash to solvents of varying pH values, solvents defined in the EPA's Synthetic Precipitation Leaching Procedure (SPLP) and Toxicity Characteristic Leaching Procedure (TCLP), rainwater, deionized water, and seawater. The generated leachates were analyzed for inorganic As(III) and As(V) and the organoarsenic species, monomethylarsonic acid (MMAA) and dimethylarsinic acid (DMAA), using high-performance liquid chromatography followed by hydride generation and atomic fluorescence spectrometry (HPLC-HG-AFS). Only the inorganic species were detected in any of the wood leachates; no organoarsenic species were found. Inorganic As(V) was the major detectable species leaching from both new and weathered wood. The weathered wood leached relatively more overall arsenic and was attributed to increased inorganic As(III) leaching. The greater presence of As(III) in the weathered wood samples as compared to the new wood samples may be due to natural chemical and biological transformations during the weathering process. CCA-treated wood ash leached more arsenic than unburned wood using the SPLP and TCLP, and ash samples leached more inorganic As(III) than the unburned counterparts. Increased leaching was due to higher concentrations of arsenic within the ash and to the conversion of some As(V) to As(III) during combustion.

Arsenates↗

Evaluation of XRF and LIBS technologies for on-line sorting of CCA-treated wood waste.

Contamination of wood waste with chromated copper arsenate greatly limits recycling opportunities for the wood waste as a whole. Separation of CCA-treated wood from other wood types is one means by which such contamination can be removed. The purpose of the current study was to evaluate two detector technologies for sorting CCA-treated wood from other wood types. The detector technologies evaluated included X-ray fluorescence spectroscopy (XRF) and laser induced breakdown spectroscopy (LIBS). The XRF detector system utilized in this study was capable of rapidly detecting the presence of CCA in painted wood, wet wood, heartwood, sapwood, and at portions of the wood containing knots. Furthermore, the XRF system was capable of distinguishing between CCA-treated wood and wood treated with alternative wood treatment preservatives, but was limited by the fact that it was not designed for on-line operation so tests were conducted in a batch mode on a conveyor. The analysis time used in this study (3 s) can be decreased significantly for an XRF system designed specifically for on-line operation. The LIBS system developed for this study was found to effectively identify CCA-treated wood for pieces ranging in thickness from 1 to 8 cm. High sorting efficiencies were noted when 10 laser shots were taken on a piece of wood. Furthermore, the LIBS system was found to be effective for identifying wood that has been coated with stains and paints in addition to identifying wood that has been CCA treated. The major drawback with the LIBS system developed in this study was the limited laser pulse energy. With an increase in laser pulse energy it is anticipated that the working focal length of the LIBS system can be increased to enable the monitoring of wood samples of more variable thicknesses. Limitations associated with analysis of very rotted pieces of wood and wet wood can also be overcome by using a higher pulse energy laser. Overall, both technologies show incredible promise for sorting CCA-treated wood from other wood types. The next recommended step would be to run an improved full-scale operation at one facility to document sorting efficiencies and fine-tune the improvements proposed in the current study. Such a study could potentially open-the-door for more widespread sorting of wood waste.

Arsenates↗

Leaching of lead from computer printed wire boards and cathode ray tubes by municipal solid waste landfill leachates.

The proper management of discarded electronic devices (E-waste) is an important issue for solid waste professionals because of the magnitude of the waste stream and because these devices often contain a variety of toxic metals (e.g., lead). While recycling of E-waste is developing, much of this waste stream is disposed in landfills. Leaching tests are frequently used to characterize the potential of a solid waste to leach when disposed in a landfill. In the United States, the Toxicity Characteristic Leaching Procedure (TCLP) is used to determine whether a solid waste is a hazardous waste by the toxicity characteristic. The TCLP is designed to simulate worse-case leaching in a landfill environment where the waste is co-disposed with municipal solid waste (MSW). While the TCLP is a required analysis from a regulatory perspective, the leachate concentrations measured may not accurately reflect the concentrations observed under typical landfill conditions. Another method that can be performed to assess the degree a pollutant might leach from a waste in a landfill is to use actual landfill leachate as the leaching solution. In this study, two lead-containing components found in electronic devices (printed wire boards from computers and cathode ray tubes from computers and televisions) were leached using the TCLP and leachates from 11 Florida landfills. California's Waste Extraction Test (WET) and the Synthetic Precipitation Leaching Procedure were also performed. The results indicated that the extractions using MSW landfill leachates resulted in lower lead concentrations than those by the TCLP. The pH of the leaching solution and the ability of the organic acids in the TCLP and WET to complex with the lead are factors that regulate the amount of lead leached.

Electronics↗

Impact of chromated copper arsenate (CCA) in wood mulch.

The production of landscape mulch is a major market for the recycling of yard trash and waste wood. When wood recovered from construction and demolition (C&D) debris is used as mulch, it sometimes contains chromated copper arsenate (CCA)-treated wood. The presence of CCA-treated wood may cause some potential environmental problems as a result of the chromium, copper, and arsenic present. Research was performed to examine the leachability of the three metals from a variety of processed wood mixtures in Florida. The mixtures tested included mixed wood from C&D debris recycling facilities and mulch purchased from retail outlets. The synthetic precipitation leaching procedure (SPLP) was performed to examine the leaching of chromium, copper and arsenic. Results were compared to Florida's groundwater cleanup target levels (GWCTLs). Eighteen of the 22 samples collected from C&D debris processing facilities leached arsenic at concentrations greater than Florida's GWCTL of 50 microg/l. The mean leachable arsenic concentration for the C&D debris samples was 153 microg/l with a maximum of 558 microg/l. One of the colored mulch samples purchased from a retail outlet leached arsenic above 50 microg/l, while purchased mulch samples derived from virgin materials did not leach detectable arsenic (<5 microg/l). A mass balance approach was used to compute the potential metal concentrations (mg/kg) that would result from CCA-treated wood being present in wood mulch. Less than 0.1% CCA-treated wood would cause a mulch to exceed Florida's residential clean soil guideline for arsenic (0.8 mg/kg).

Arsenates↗

Municipal solid waste in situ moisture content measurement using an electrical resistance sensor.

Moisture content (MC) is a crucial parameter for degradation of solid waste in landfills. Present MC measurement techniques suffer from several drawbacks. A moisture sensor for measurement of in situ moisture content of solid waste in landfills was developed. The sensor measures the electrical resistance across the granular matrix of the sensor, which in turn can be correlated to moisture content. The sensor was also equipped with a thermocouple and tubing that permits simultaneous measurement of temperature and gas sampling. The electrical conductivity of the surrounding moisture and the temperature in the matrix both affect the resistance measurements. This paper describes the results of laboratory experiments designed to select the appropriate granular media particle size, measure the influence of moisture electrical conductivity and temperature, and develop calibration relationships between measured resistance and gravimetrically determined moisture content. With a few limitations, the sensor is able to detect MC of solid waste under conditions allowing moisture movement into the sensor. The application of this technique shows promise for use in bioreactor landfills where high moisture contents are expected and desired.

Biodegradation, Environmental↗

Characteristics of chromated copper arsenate-treated wood ash.

The combustion of recovered wood from construction and demolition waste as biomass fuel is a common practice. When chromated copper arsenate (CCA)-treated wood is present as part of the wood fuel mix, concentrations of arsenic, chromium, and copper become elevated in the ash. The objectives of this study were to estimate the fraction of CCA-treated wood needed to cause the ash to fail regulatory guidelines and to test a series of solvents for the purpose of extracting the metals from the ash. Ash samples were prepared in an industrial furnace using samples of CCA-treated wood, mixtures of CCA-treated wood and untreated wood, and recycled wood waste collected at construction and demolition recycling facilities. Regulatory guidelines were evaluated by measuring total metals concentrations (using neutron activation analysis) and by conducting standardized leaching tests (toxicity characteristic leaching procedure (TCLP) and synthetic precipitation leaching procedure (SPLP)) on the ash. Ten different solvents, ranging from distilled water to strong acids, were also tested for their ability to extract metals. Results of this study indicate that metal concentrations (chromium plus copper plus arsenic) can be as high as 36% of the ash by weight for treated wood samples containing high retention levels (40 kg/m(3)) of CCA. All ash samples from the combustion of 100% CCA-treated wood and mixtures containing 5% CCA-treated wood leached enough arsenic (and sometimes chromium) to be characterized as a hazardous waste under US regulations. Concentrated nitric acid, which was the most effective solvent tested, was capable of removing between 70 and 100% of the copper, between 20 and 60% of the chromium, and 60 and 100% of the arsenic for samples characterized by low retention levels. A particular finding of interest was the efficiency of distilled water and other weak solvents to extract measurable amounts of chromium, especially for ash samples containing low retention levels of CCA. Citric acid was particularly effective at removing arsenic (between 40 and 100%) for ash samples produced from wood containing low CCA retention levels.

Arsenates↗