PubMed Health⌕ Search

Biomedical subjects

Timothy Griffin

Publications and source records attributed to Timothy Griffin.

2 recordsLinked to original sources

Phase II study of clofarabine in pediatric patients with refractory or relapsed acute lymphoblastic leukemia.

PURPOSE: To evaluate the efficacy and safety of clofarabine, a novel deoxyadenosine analog, in pediatric patients with refractory or relapsed acute lymphoblastic leukemia (ALL). PATIENTS AND METHODS: In a phase II, open-label, multicenter study, 61 pediatric patients with refractory or relapsed ALL received clofarabine 52 mg/m2 intravenously over 2 hours daily for 5 days, every 2 to 6 weeks. The median age was 12 years (range, 1 to 20 years), and the median number of prior regimens was three (range, two to six regimens). RESULTS: The response rate was 30%, consisting of seven complete remissions (CR), five CRs without platelet recovery (CRp), and six partial remissions. Remissions were durable enough to allow patients to proceed to hematopoietic stem-cell transplantation (HSCT) after clofarabine. Median CR duration in patients who did not receive HSCT was 6 weeks, with four patients maintaining CR or CRp for 8 weeks or more (8+, 12, 37+, and 48 weeks) on clofarabine therapy alone. The most common adverse events of grade > or = 3 were febrile neutropenia, anorexia, hypotension, and nausea. CONCLUSION: Clofarabine is active as a single agent in pediatric patients with multiple relapsed or refractory ALL. The toxicity profile is as expected in this heavily pretreated patient population. Studies exploring rational combinations of clofarabine with other agents are ongoing in an effort to maximize clinical benefit.

Adenine Nucleotides↗

A modular injection system, multilevel sampler, and manifold for tracer tests.

Ground water injection and sampling systems were developed for bacterial transport experiments in both homogenous and heterogeneous unconsolidated, surficial aquifers. Two types of injection systems, a large single tank and a dynamic mixing tank, were designed to deliver more than 800 L of amended ground water to the aquifer over 12 hours, without altering the ground water temperature, pH, Eh, or dissolved gas composition. Two types of multilevel samplers (MLSs) were designed and installed. Permanent MLSs performed well for the homogenous surficial aquifer, but their installation procedure promoted vertical mixing, which could obfuscate experimental data obtained from vertically stratified, heterogeneous aquifers. A novel, removable MLS was designed to fit in 2- and 4-inch wells. Expandable O-rings between each sampling port hydraulically isolated each port for sample collection when a nut was tightened at the land surface. A low-cost vacuum manifold system designed to work with both MLS designs used 50 mL centrifuge tubes to efficiently sample 12 MLS ports with one peristaltic pump head. The integrated system was developed and used during four field campaigns over a period of three years. During each campaign, more than 3000 ground water samples were collected in less than one week. This system should prove particularly useful for ground water tracer, injection, and push-pull experiments that require high-frequency and/or high-density sampling.

Bacteria↗