PubMed Health⌕ Search

Biomedical subjects

Timothy J Gilbert

Publications and source records attributed to Timothy J Gilbert.

2 recordsLinked to original sources

Activation of coagulation occurs after electrical cardioversion in patients with chronic atrial fibrillation despite optimal anticoagulation with warfarin.

BACKGROUND: There is evidence for the activation of the coagulation system and a hypercoagulable state following cardioversion. The aim of the study was to determine whether electrical cardioversion in patients with chronic atrial fibrillation induced a prothrombotic state despite optimal anticoagulation. We studied the effects of electrical cardioversion on plasma levels of fibrinogen, antithrombin III, protein C and D-dimers. METHODS: We studied 24 patients with chronic atrial fibrillation who were on optimal anticoagulation and were referred for electrical cardioversion. Samples of venous blood were taken 2 h pre and post cardioversion and 1 month later. RESULTS: Plasma median concentrations of fibrinogen decreased significantly from 3.8 g/l (interquartile range 3.1-4.2 g/l) before cardioversion to 3.5 g/l (interquartile range 2.9-3.9 g/l) 2 h after cardioversion levels (P=0.004). The fibrinogen levels at 1 month post cardioversion (3.45 g/l, interquartile range 3.1-3.9 g/l) were also significantly lower than baseline (P=0.02). Plasma median levels of antithrombin III fell from 93.5 U/dl (interquartile range 89.3-97.0 U/dl) pre cardioversion to 89.5 U/dl (interquartile range 83.0-93.0 U/dl) 2 h after cardioversion (P=0.001) and returned to normal by 1 month (94.0 U/dl; interquartile range 89.3-98.5 U/dl; P=0.0001). There were no significant changes in plasma median D-dimer or protein C levels at any time. CONCLUSIONS: We have demonstrated a significant fall in the plasma fibrinogen and antithrombin III levels in patients with chronic atrial fibrillation early after electrical cardioversion, indicating thrombin generation. This study suggests that there are haemostatic changes of thrombogenesis induced by cardioversion despite optimal anticoagulation with warfarin.

Adult↗

Quadricuspid aortic valves.

Quadricuspid aortic valves (QAV) are a rare but well recognized cause of significant aortic regurgitation. The first case was found reported in 1862. Since then there have been 110 reported cases of QAV and we report 4 more. Previously, these were diagnosed at the time of surgery or postmortem examination. With advances in echocardiography, including harmonic imaging, and also the advent of transesophageal echocardiography, more cases are being diagnosed prior to surgery. We describe four more cases, three diagnosed preoperatively and one at the time of surgery, and then review the previously reported cases. Of the 114 cases reported, 46 had the aortic valve replaced, most commonly in the 5th and 6th decade of life. Hurwitz and Roberts classified quadricuspid valves according to the size of the leaflets. It has previously been believed that QAVs with four equal sized leaflets were less likely to develop significant aortic regurgitation; however, on review of the available cases, this would not appear to be the case. The preoperative diagnosis of QAVs is important as they can be associated with abnormally placed coronary ostium. Of the 114 cases reported, there are 10 reports of abnormally placed ostia. There has been at least one reported case of death occurring because of obstruction of an abnormally placed right coronary ostium by a prosthetic aortic valve.

Adult↗