PubMed Health⌕ Search

Biomedical subjects

Timothy Wachs

Publications and source records attributed to Timothy Wachs.

4 recordsLinked to original sources

Quantitative mass spectrometric determination of methylphenidate concentration in urine using an electrospray ionization source integrated with a polymer microchip.

We have demonstrated the use of a simple microfabricated electrospray ionization source for coupling microfluidic chips to mass spectrometry (MS). A polymer-based microchip, coupled to a triple quadrupole mass spectrometer, has been employed for direct infusion quantitative bioanalysis of methylphenidate (Ritalin) extracted from human urine samples. The approach used a microfabricated polymer electrospray emitter to couple a microfluidic channel to a stable electrospray ionization source. The microchip was fabricated from cycloolefin plastic plate by hot embossing and thermal bonding. This microfluidic chip contained two independent microfluidic channels, integrated with two corresponding electrospray emitters and an internal gold electrode. Liquid-liquid extraction was used to prepare urine samples, spiked with methylphenidate. A trideuterated analogue of methylphenidate (methylphenidate-d(3)) was used as the internal standard for the analysis. The system showed good electrospray stability and reproducibility with different spray tips. Four different electrospray tips were used to analyze the same sample, and the results showed very small variation with a relative standard deviation of 1.4%. A standard curve prepared for methylphenidate in urine (R(2) = 0.999) was linear over the range of 0.4-800 ng/mL. The precision of the quality control samples for three different concentrations ranged from 19.1% at 20 ng/mL, 3.2% at 200 ng/mL, to 3.5% at 667 ng/mL while the accuracy was 96.3% at 20 ng/mL, 101.2% at 200 ng/mL, and 101.6% at 667 ng/mL. No system carryover was detected even when the same device was used for sequential analysis. These results suggest the potential of this microdevice for MS-based quantitative analysis in drug discovery and development.

Electrophoresis, Microchip↗

Chip-based P450 drug metabolism coupled to electrospray ionization-mass spectrometry detection.

A chip-based P450 in vitro metabolism assay coupled with ESI-MS and ESI-MS/MS detection is described in this paper. The chips were made of a cyclic olefin polymer using a hot embossing process. The introduction of reagent solutions into the chip was carried out using fused-silica capillaries coupled to two syringes with the flow rate controlled by a syringe pump. Initial experiments described here employed a small commercial guard column in an off-chip format to desalt and concentrate the products of the enzymatic reaction prior to ESI-MS analysis. The system was used both to yield the Michaelis constant (K(m)) of the P450 biotransformation of imipramine into desipramine and to determine the IC50 value of a chemical inhibitor (tranylcypromine) for this CYP2C19-mediated reaction. The results demonstrated that the kinetics of the reaction inside the 4-microL volume within the channels of the cyclic olefin polymer chip provided results in agreement with those reported in the literature using conventional assays. The above reactions were carried out using human liver microsomes, and the metabolites were detected by ESI-MS showing the potential of the chip-based P450 reaction for metabolite screening studies as well as for P450 inhibition assays. A porous monolithic column was subsequently integrated into the chip to perform the reaction mixture cleanup process in an integrated fashion on the chip that is necessary for ESI-MS detection. The miniature monolithic SPE column was prepared in situ inside the chip via UV-initiated polymerization. The results obtained using the integrated system demonstrated the possibility of performing P450 enzymatic reactions in a microvolume reaction chamber coupled directly to ESI-MS detection and required less than 4 microg of HLM protein.

Alkenes↗

A device for automated direct sampling and quantitation from solid-phase sorbent extraction cards by electrospray tandem mass spectrometry.

A new solid-phase extraction (SPE) device in the 96-well format (SPE Card) has been employed for automated off-line sample preparation of low-volume urine samples. On-line automated analyte elution via SPE and direct quantitation by micro ion spray mass spectrometry is reported. This sample preparation device has the format of a microtiter plate and is molded in a plastic frame which houses 96 separate sandwiched 3M Empore sorbents (0.5-mm-thickness, 8-microm particles) covered on both sides by a microfiber support material. Ninety-six discrete SPE zones, each 7 mm in diameter, are imbedded into the sheet in the conventional 9-mm pitch (spacing) of a 96-well microtiter plate. In this study one-quarter of an SPE Card (24 individual zones) was used merely as a convenience. After automated off-line interference elution of applied human urine from 24 samples, a section of SPE Card is mounted vertically on a computer-controlled X, Y, Z positioner in front of a micro ion spray direct sampling tube equipped with a beveled tip. The beveled tip of this needle robotically penetrates each SPE elution zone (sorbent disk) or stationary phase in a serial fashion. The eluted analytes are sequentially transferred directly to a microelectrosprayer to obtain tandem mass spectrometric (MS/MS) analysis. This strategy precludes any HPLC separation and the associated method development. The quantitative determination of Ritalin (methylphenidate) from fortified human urine samples is demonstrated. A trideuterated internal standard of methylphenidate was used to obtain ion current response ratios between the parent drug and the internal standard. Human control urine samples fortified from 6.6 to 3300 ng/mL (normal therapeutic levels have been determined in other studies to be between 50 and 100 ng/mL urine) were analyzed and a linear calibration curve was obtained with a correlation coefficient of 0.9999, where the precision of the quality control (QC) samples ranged from 9.6% at the 24 ng/mL QC level to 1.2% at the 3000 ng/mL QC level, and the accuracy for the four levels of QC samples ranged from 98.1% to 100.3%. The QC samples were prepared at four concentrations which included 24, 240, 1200, and 3000 ng/mL, respectively. The run time per sample in this work was 1.5 min not including the sample preparation time.

Automation↗

Rapid forensic selected reaction monitoring liquid chromatography/mass spectrometry determination of ionophore antibiotics found at toxic levels in animal feeds.

A rapid, accurate, and selective method was developed for the forensic determination of ionophore antibiotics in animal feeds. A simple extraction procedure and liquid chromatography/tandem mass spectrometry (LC/MS/MS) in the selected reaction monitoring (SRM) mode were used for rapid identification and confirmation of monensin and lasalocid in feed samples and for quantitation of monensin. Extracts from a homogenous portion of ground feeds were prepared using liquid-solid extraction and liquid-liquid extraction techniques. Feed extracts were further purified by a simple defatting and solvent wash step and then concentrated to dryness. Feed extract residues were reconstituted in 1 mL LC mobile phase and a 2 microL aliquot injected into the SRM LC/MS system. The latter system used a C18, 100 x 2.0 mm, LC column coupled to a PE-Sciex API 2000 tandem triple quadrupole mass spectrometer equipped with a TurbolonSpray LC/MS interface. Feed samples were extracted and analyzed for the determination of monensin and lasalocid within a couple of hours. Control feed samples fortified with monensin at concentrations from 50 ppb to 5 ppm provided a linear response and calibration curve across this range with a correlation coefficient of 0.996.

Animal Feed↗