PubMed Health⌕ Search

Biomedical subjects

Timothy Walker

Publications and source records attributed to Timothy Walker.

2 recordsLinked to original sources

Factors related to false- versus true-positive neuromonitoring changes in adolescent idiopathic scoliosis surgery.

STUDY DESIGN: A retrospective study of 134 adolescent patients who underwent surgical correction of idiopathic scoliosis between June 1992 and August 1998 was conducted. OBJECTIVE: To examine factors related to changes in somatosensory-evoked potentials with or without neurogenic motor-evoked potentials. SUMMARY OF BACKGROUND DATA: Studies document and demonstrate threshold criteria for changes in neuromonitoring that predict changes in spinal cord function. Rates of false-negative occurrences are low, yet higher rates of false-positive findings may result. METHODS: All the patients had somatosensory monitoring, and 71 patients had both somatosensory-evoked potential and neurogenic motor-evoked potential monitoring. Gender, age, curve types, duration of surgery, type and amount of instrumentation, and amount of correction were examined for their effects on monitoring. Estimated blood volume loss as well as high and low mean arterial pressure and its variance were assessed at the start, middle, and conclusion of the procedure. RESULTS: According to the findings, 122 patients (91%) had no monitoring changes and no postoperative neurologic deficit. Six patients (4.5%) had false-positive readings. Six patients had a postoperative motor or sensory deficit, all of which resolved within 18 months. False-positive readings were associated with greater variability in mean arterial pressure. No consistent predictions could be made about the incidence of cord injury if neuromonitoring changes returned to baseline before the end of surgery. CONCLUSIONS: Questions remain about the predictive accuracy of somatosensory-evoked and neurogenic motor-evoked potentials. According to the findings in this study, in which there were no false-negative readings and a modest false-positive rate, continued use of these methods is recommended. Higher false-positive rates were seen in patients with greater lability in mean arterial pressure. A wake-up test is recommended for all cases in which threshold monitoring changes occur because cases of spinal cord injury may exist even when monitored variables return to baseline.

Adolescent↗

Surface sampling methods for Bacillus anthracis spore contamination.

During an investigation conducted December 17-20, 2001, we collected environmental samples from a U.S. postal facility in Washington, D.C., known to be extensively contaminated with Bacillus anthracis spores. Because methods for collecting and analyzing B. anthracis spores have not yet been validated, our objective was to compare the relative effectiveness of sampling methods used for collecting spores from contaminated surfaces. Comparison of wipe, wet and dry swab, and HEPA vacuum sock samples on nonporous surfaces indicated good agreement between results with HEPA vacuum and wipe samples. However, results from HEPA vacuum sock and wipe samples agreed poorly with the swab samples. Dry swabs failed to detect spores >75% of the time when they were detected by wipe and HEPA vacuum samples. Wipe samples collected after HEPA vacuum samples and HEPA vacuum samples collected after wipe samples indicated that neither method completely removed spores from the sampled surfaces.

Bacillus anthracis↗