PubMed Health⌕ Search

Biomedical subjects

Tine De Backer

Publications and source records attributed to Tine De Backer.

3 recordsLinked to original sources

Brief report: The accuracy of parents for the thoughts and feelings of their adolescent suffering from chronic fatigue: a preliminary study of empathy.

OBJECTIVE: This study examined the actual and estimated empathic accuracy (EA) of the parents of adolescents with chronic fatigue syndrome (CFS). METHODS: The actual EA of both parents (n = 24) was assessed in relation to the thoughts and feelings of their child (n = 14) about CFS and about other life events. Adolescents were also asked to estimate the parents' EA. RESULTS: For the actual EA, both parents were significantly less accurate regarding the adolescent's thoughts and feelings about CFS than about other life events. Fathers were just as empathically accurate as mothers. For the estimated EA, however, results indicated that adolescents perceived their mother to be more empathically accurate than their father. Actual EA and estimated EA about CFS were negatively correlated for fathers, not for mothers. CONCLUSIONS: Results are discussed in terms of the importance of assessing EA in relation to other dimensions of empathic understanding and distress in the observer.

Adolescent↗

Prevalence of mechanical dyssynchrony in patients with heart failure and preserved left ventricular function (a report from the Belgian Multicenter Registry on dyssynchrony).

The present study evaluated the prevalence of mechanical inter- and intraventricular dyssynchrony in patients with heart failure and preserved left ventricular (LV) ejection fraction (LVEF). We studied 138 patients with heart failure (age 67+/-11 years; 76% men); 60 patients had preserved LVEF (>40%). Using conventional Doppler echocardiography, an interventricular mechanical delay>or=40 ms was defined as interventricular dyssynchrony. Using pulse-wave tissue Doppler imaging, the time from the beginning of the QRS complex to onset of systolic motion was measured in 4 basal LV segments. A dispersion of >or=60 ms was defined as intraventricular dyssynchrony. The prevalence of inter- and intraventricular dyssynchrony was lower in patients with preserved LVEF than in those with reduced LVEF (17% vs 41%, p<0.01 for interventricular dyssynchrony, 18% vs 36%, p<0.01 for intraventricular dyssynchrony). However, patients with preserved LVEF and a QRS width>or=120 ms had higher values for the parameters for inter- and intraventricular dyssynchrony than patients with a QRS width<120 ms (interventricular mechanical delay 33+/-20 vs 20+/-16 ms, p<0.05; tissue Doppler imaging dispersion 42+/-26 vs 33+/-22 ms, p<0.05). In patients with a QRS width>or=120 ms, the prevalence of inter- and intraventricular dyssynchrony was comparable for patients with preserved and reduced LVEF (42% vs 55%, p=NS for interventricular dyssynchrony and 45% vs 46%, p=NS for intraventricular dyssynchrony). In conclusion, the prevalence of inter- and intraventricular dyssynchrony was low (17% and 18%, respectively) in patients with heart failure and preserved LVEF. However, in the presence of a QRS width of >or=120 ms, this prevalence increased to almost 50%, comparable to that for patients with heart failure and reduced LVEF and a QRS width of >or=120 ms.

Aged↗

Tailored echocardiographic interventricular delay programming further optimizes left ventricular performance after cardiac resynchronization therapy.

BACKGROUND: The aim of cardiac resynchronization therapy is correction of left ventricular (LV) dyssynchrony. However, little is known about the optimal timing of LV and right ventricular (RV) stimulation. OBJECTIVES: The purpose of this study was to evaluate the acute hemodynamic effects of biventricular pacing, using a range of interventricular delays in patients with advanced heart failure. METHODS: Twenty patients with dilated ischemic (n = 12) and idiopathic (n = 8) cardiomyopathy (age 66 +/- 6 years, New York Heart Association class III-IV, LV end-diastolic diameter >55 mm, ejection fraction 22% +/- 18%, and QRS 200 +/- 32 ms) were implanted with a biventricular resynchronization device with sequential RV and LV timing (VV) capabilities. Tissue Doppler echocardiographic parameters were measured during sinus rhythm before implantation and following an optimal AV interval with both simultaneous and sequential biventricular pacing. The interventricular interval was modified by advancing the LV stimulus (LV first) or RV stimulus (RV first) up to 60 ms. For each stimulation protocol, standard echocardiographic Doppler and tissue Doppler imaging (TDI) echo were used to measure the LV outflow tract velocity-time integral, LV filling time, intraventricular delay, and interventricular delay. RESULTS: The highest velocity-time integral was found in 12 patients with LV first stimulation, 5 patients with RV first stimulation, and 3 patients with simultaneous biventricular activation. Compared with simultaneous biventricular pacing, the optimized sequential biventricular pacing significantly increased the velocity-time integral (P <.001) and LV filling time (P = .001) and decreased interventricular delay (P = .013) and intraventricular delay (P = .010). The optimal VV interval could not be predicted by any clinical nor echocardiographic parameter. At 6-month follow-up, the incidence of nonresponders was 10%. CONCLUSION: Optimal timing of the interventricular interval results in prolongation of the LV filling time, reduction of interventricular asynchrony, and an increase in stroke volume. In patients with advanced heart failure undergoing cardiac resynchronization therapy, LV hemodynamics may be further improved by optimizing LV-RV delay.

Aged↗