PubMed Health⌕ Search

Biomedical subjects

Todd Albert

Publications and source records attributed to Todd Albert.

9 recordsLinked to original sources

Surgical vs nonoperative treatment for lumbar disk herniation: the Spine Patient Outcomes Research Trial (SPORT) observational cohort.

CONTEXT: For patients with lumbar disk herniation, the Spine Patient Outcomes Research Trial (SPORT) randomized trial intent-to-treat analysis showed small but not statistically significant differences in favor of diskectomy compared with usual care. However, the large numbers of patients who crossed over between assigned groups precluded any conclusions about the comparative effectiveness of operative therapy vs usual care. OBJECTIVE: To compare the treatment effects of diskectomy and usual care. DESIGN, SETTING, AND PATIENTS: Prospective observational cohort of surgical candidates with imaging-confirmed lumbar intervertebral disk herniation who were treated at 13 spine clinics in 11 US states and who met the SPORT eligibility criteria but declined randomization between March 2000 and March 2003. INTERVENTIONS: Standard open diskectomy vs usual nonoperative care. MAIN OUTCOME MEASURES: Changes from baseline in the Medical Outcomes Study Short-Form Health Survey (SF-36) bodily pain and physical function scales and the modified Oswestry Disability Index (American Academy of Orthopaedic Surgeons/MODEMS version). RESULTS: Of the 743 patients enrolled in the observational cohort, 528 patients received surgery and 191 received usual nonoperative care. At 3 months, patients who chose surgery had greater improvement in the primary outcome measures of bodily pain (mean change: surgery, 40.9 vs nonoperative care, 26.0; treatment effect, 14.8; 95% confidence interval, 10.8-18.9), physical function (mean change: surgery, 40.7 vs nonoperative care, 25.3; treatment effect, 15.4; 95% CI, 11.6-19.2), and Oswestry Disability Index (mean change: surgery, -36.1 vs nonoperative care, -20.9; treatment effect, -15.2; 95% CI, -18.5. to -11.8). These differences narrowed somewhat at 2 years: bodily pain (mean change: surgery, 42.6 vs nonoperative care, 32.4; treatment effect, 10.2; 95% CI, 5.9-14.5), physical function (mean change: surgery, 43.9 vs nonoperavtive care 31.9; treatment effect, 12.0; 95% CI; 7.9-16.1), and Oswestry Disability Index (mean change: surgery -37.6 vs nonoperative care -24.2; treatment effect, -13.4; 95% CI, -17.0 to -9.7). CONCLUSIONS: Patients with persistent sciatica from lumbar disk herniation improved in both operated and usual care groups. Those who chose operative intervention reported greater improvements than patients who elected nonoperative care. However, nonrandomized comparisons of self-reported outcomes are subject to potential confounding and must be interpreted cautiously. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00000410.

Adult↗

Wear and corrosion in retrieved thoracolumbar posterior internal fixation.

STUDY DESIGN: Posterior thoracolumbar spine implants retrieved as part of routine clinical practice over a 2-year period were analyzed to identify wear and corrosion. OBJECTIVE: Engineering analyses of retrieved posterior instrumentation for indications of performance and failure and correlation of this information with clinical factors. SUMMARY OF BACKGROUND DATA: Recent studies have reported spinal instrumentation particulate wear debris and have noted the importance of design considerations at implant connector interfaces. METHODS: A total of 57 implants were analyzed from patients (39 female, 18 male) whose average age at implantation was 43.9 years (range, 13.7-77.4 years). Time of implantation ranged from 2 months to 13.5 years. The top 3 implantation diagnoses were radiculopathy (33%), scoliosis (30%), and back pain (25%). Metallurgical analyses were performed to characterize the wear and/or corrosion, and fractures of the implants. RESULTS: Wear was present in 75%, corrosion in 39%, and fractures in 7% of the retrieved implants. Wear and/or corrosion was more prevalent, with respect to the total number of implants retrieved, in implants that had been in service at least 1 year. There was no evidence of corrosion in any of the Ti implants, whereas corrosion was present (with wear) in 58% of the stainless steel (SS) implants. Wear and corrosion were more frequently observed in long rods than in short rods. Implantation times were longer for SS implants than for Ti implants. CONCLUSIONS: Retrieved rods exhibited corrosion, wear, and fracture, with wear and corrosion mainly located at the interfaces with hooks, screws, or cross-connectors. The mechanisms causing this material loss in situ, as well as what local or systemic responses it may stimulate are of clinical significance and should be studied further.

Adolescent↗

Recurrent laryngeal nerve palsy after anterior cervical spine surgery: the impact of endotracheal tube cuff deflation, reinflation, and pressure adjustment.

BACKGROUND: Vocal fold immobility (paresis or paralysis) from recurrent laryngeal nerve injury remains an important cause of morbidity after anterior cervical spine surgery. A maneuver involving endotracheal tube (ETT) cuff manipulation has been proposed to reduce its incidence. This study is a randomized, prospective, double-blind investigation to test the hypothesis that ETT cuff manipulation reduces the incidence of postoperative vocal fold immobility after anterior cervical spine surgery. METHODS: One hundred patients scheduled to undergo anterior cervical spine surgery were randomly assigned to one of two groups. After inducing general endotracheal anesthesia, patients in the intervention group had their ETT cuff pressures maintained at 20 mmHg or less. After placement of self-retaining retractors, the ETT cuff was deflated for 5 s and then reinflated. Patients in the control group had no further manipulation of their ETT once the cuff was inflated after intubation. Cuff pressures in both groups were recorded before skin incision (baseline) and after placement of self-retaining retractors (peak). Patients' vocal fold motion was evaluated by indirect laryngoscopy performed preoperatively and postoperatively. The examination was videotaped and reviewed by a blinded otolaryngologist. Postoperative vocal fold motion was graded as normal, paretic, or paralyzed. RESULTS: Complete data were available in 94 patients. The incidence of vocal fold paralysis was 3.2% (95% confidence interval, 0.7-9.4%). Cuff manipulation decreased ETT cuff pressure but did not reduce the incidence of vocal fold immobility (15.4% vs. 14.5%). CONCLUSION: Endotracheal tube cuff deflation/reinflation and pressure adjustment do not reduce the incidence of vocal fold immobility in anterior cervical spine surgery.

Adult↗

Detection of esophageal perforation using intraesophageal dye injection.

OBJECTIVES: Esophageal perforation complicating anterior cervical spine surgery is a potentially fatal complication. Early identification and immediate treatment may lower adverse effects for the patient. The purpose of this study is to assess the efficacy of intraesophageal dye injection to detect an esophageal injury and to test two novel techniques. METHOD: Ten cadaveric specimens were dissected using an anteromedial Smith-Robinson approach. Each was sequentially tested by a control and three dye injection techniques: technique A: nasogastric tube alone; technique B: nasogastric tube plus a distally placed Foley catheter; technique C: proximal plus a distally placed Foley catheter. Each technique was tested against esophageal perforations created by needle puncture (21-gauge, 18-gauge, and 14-gauge) and by a 2-mm high-speed burr. Dye visualization was independently graded as present or absent by two authors. RESULTS: In the control trial, no dye leak was visualized in any of the 10 specimens. In technique A, 0 of 10 21-gauge perforations, 1 of 10 18-gauge perforations, 2 of 10 14-gauge perforations, and 6 of 10 burr perforations were visualized. In technique B, 1 of 10 21-gauge perforations, 8 of 10 18-gauge perforations, 9 of 10 14-gauge perforations, and 9 of 10 burr perforations were visualized. In technique C, 0 of 10 21-gauge perforations, 9 of 10 18-gauge perforations, 10 of 10 14-gauge perforations, and 7 of 10 burr perforations were visualized. CONCLUSIONS: The study suggests that intraesophageal dye injection via nasogastric tube alone should not be relied upon to exclude the presence of esophageal perforation. Two novel techniques showed an improved, though limited, capability of detecting esophageal perforations.

Cadaver↗

Physical and monetary costs associated with autogenous bone graft harvesting.

Although autogenous iliac bone is frequently used for bone graft, many well-documented complications are associated with this procedure-including chronic pain; nerve, arterial, and ureteral injury; herniation of abdominal contents; sacroiliac joint instability; pelvic fractures; hematoma; and infection. An understanding of the morbidities associated with bone graft harvesting and of the strategies for avoiding them is imperative for surgeons using this grafting source. In addition, although synthetic grafting materials are considered relatively expensive compared with autogenous sources, the majority of physicians are unaware of the actual direct and indirect costs associated with autogenous bone graft harvesting. Contemporary allograft and synthetic grafting composites are being developed to optimize and surpass the native qualities of autogenous sources (ie, osteogenesis, osteoinductivity, osteoconductivity). Careful comparison of the cost of these alternative sources with the physical and monetary costs of autogenous bone graft will undoubtedly make allograft, recombinant, synthetic graft composites the logical choice in the very near future.

Anesthesia↗

Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption.

OBJECT: Anterior cervical discectomy and fusion (ACDF) is a widely accepted treatment for anterior degenerative or traumatic instability of the cervical spine. To reduce or eliminate complications such as implant migration and failure, imaging degradation, and fusion stress shielding that are occasionally associated with spinal instrumentation, attention has been given to the use of bioresorbable anterior cervical plate (ACP) devices. This paper is a preliminary report of a retrospective series in which a resorbable mesh and screw system was used for graft containment in single-level ACDF. METHODS: A review of patient charts and imaging studies was conducted to determine functional outcome, fusion success, and potential soft-tissue reaction to implant resorption. Nine patients with a cervical degenerative disc disease or traumatic disc disruption were treated between October 2001 and March 2002. Follow up averaged 206 days. Eight patients were found to have an excellent result, one patient had a good result, and no patients had a satisfactory or poor result. At the time of follow-up examination, 77% of patients were found to have a radiographically solid fusion. The two patients without a solid fusion were examined only an average 8 months postoperatively and manifested no symptoms related to fusion nonhealing. No significant soft-tissue reaction was noted clinically or radiographically in any of the patients. CONCLUSIONS: The results of this preliminary study indicate that bioresorbable ACP systems for single-level ACDF are both safe and effective.

Absorbable Implants↗

Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disk disruption.

Anterior cervical diskectomy and fusion is a widely accepted treatment for anterior management of degenerative or traumatic instability of the cervical spine. To reduce or eliminate complications such as implant migration and failure, imaging degradation, and fusion stress shielding that are occasionally associated with spinal instrumentation, attention has been given to the use of bioresorbable anterior cervical plating devices. This paper is a preliminary report of a retrospective series in which a resorbable mesh and screw system (OS Reconstructive Mesh, MacroPore Biosurgery Inc, San Diego, Calif) was used for graft containment in single-level anterior cervical diskectomy and fusion. A review of patient charts and imaging studies was conducted to determine functional outcome, fusion success, and potential soft-tissue reaction to implant resorption. Nine patients with a diagnosis of cervical degenerative disk disease or traumatic disk disruption were treated between October 2001 and March 2002. Follow-up averaged 206 days. Eight patients were found to have an excellent result, one patient had a good result, and no patients had a satisfactory or poor result. At the time of follow-up, 77% of patients (7/9) were found to have a radiographically solid fusion. The two patients without a solid fusion were only on average 8 months out from their fusion procedure and manifested no symptoms related to fusion nonhealing. No significant soft-tissue reaction was noted clinically or radiographically in any of the patients. The results of this preliminary study indicate that bioresorbable anterior cervical plating for single-level anterior cervical diskectomy and fusion is both safe and effective.

Absorbable Implants↗

Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?

BACKGROUND CONTEXT: Surgeons are hesitant to mix components made of differing metal classes for fear of galvanic corrosion complications. However, in vitro studies have failed to show a significant potential for galvanic corrosion between titanium and stainless steel, the two primary metallic alloys used for spinal implants. Galvanic corrosion resulting from metal mixing has not been described in the literature for spinal implant systems. PURPOSE: To determine whether galvanic potential significantly affects in vitro corrosion of titanium and stainless steel spinal implant components during cyclical compression bending. STUDY DESIGN/SETTING: Bilateral spinal implant constructs consisting of pedicle screws, slotted connectors, 6.35-mm diameter rods and a transverse rod connector assembled in polyethylene test blocks were tested in vitro. Two constructs had stainless steel rods with mixed stainless steel (SS-SS) and titanium (SS-Ti) components, and two constructs had titanium rods with mixed stainless steel (Ti-SS) and titanium (Ti-Ti) components. METHODS: Each construct was immersed in phosphate-buffered saline (pH 7.4) at 37 C and tested in cyclic compression bending using a sinusoidal load-controlling function with a peak load of 300 N and a frequency of 5 Hz until a level of 5 million cycles was reached. The samples were then removed and analyzed visually for evidence of corrosion. In addition, scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS) were used to evaluate the extent of corrosion at the interconnections. RESULTS: None of the constructs failed during testing. Gross observation of the implant components after disassembly revealed that no corrosion had occurred on the surface of the implants that had not been in contact with another component. The Ti-Ti interfaces showed some minor signs of corrosion only detectable using SEM and EDS. The greatest amount of corrosion occurred at the SS-SS interfaces and was qualitatively less at the SS-Ti and Ti-SS interfaces. CONCLUSIONS: The results from this study indicate that when loaded dynamically in saline, stainless steel implant components have a greater susceptibility to corrosion than titanium. Furthermore, the galvanic potential between the dissimilar metals does not cause a discernible effect on the corrosion of either. Although the mixture of titanium alloy with stainless steel is not advocated, the results of this study suggest that galvanic corrosion is less pronounced in SS-Ti mixed interfaces than in all stainless steel constructs.

Alloys↗