Todd Pawlicki

Publications and source records attributed to Todd Pawlicki.

6 recordsLinked to original sources

Evaluation of patterns of failure and subjective salivary function in patients treated with intensity modulated radiotherapy for head and neck squamous cell carcinoma.

BACKGROUND: Our aim was to correlate patterns of failure with target volume delineations in patients with head and neck squamous cell carcinoma (HNSCC) treated with intensity-modulated radiation therapy (IMRT) and to report subjective xerostomia outcomes after IMRT as compared with conventional radiation therapy (CRT). METHODS: Between January 2000 and April 2005, 69 patients with newly diagnosed nonmetastatic HNSCC underwent curative parotid-sparing IMRT at Stanford University. Sites included were oropharynx (n = 39), oral cavity (n = 8), larynx (n = 8), hypopharynx (n = 8), and unknown primary (n = 6). Forty-six patients received definitive IMRT (66 Gy, 2.2 Gy/fraction), and 23 patients received postoperative IMRT (60.2 Gy, 2.15 Gy/fraction). Fifty-one patients also received concomitant chemotherapy. Posttreatment salivary gland function was evaluated by a validated xerostomia questionnaire in 29 IMRT and 75 matched CRT patients >6 months after completing radiation treatment. RESULTS: At a median follow-up of 25 months for living patients (range, 10-60), 7 locoregional failures were observed, 5 in the gross target or high-risk postoperative volume, 1 in the clinical target volume, and 1 at the junction of the IMRT and supraclavicular fields. The 2-year Kaplan-Meier estimates for locoregional control and overall survival were 92% and 74% for definitive IMRT and 87% and 87% for postoperative IMRT patients, respectively. The mean total xerostomia questionnaire score was significantly better for IMRT than for CRT patients (p = .006). CONCLUSIONS: The predominant pattern of failure in IMRT-treated patients is in the gross tumor volume. Parotid sparing with IMRT resulted in less subjective xerostomia and may improve quality of life in irradiated HNSCC patients.

Carcinoma, Squamous Cell↗

Indirect MR lymphangiography of the head and neck using conventional gadolinium contrast: a pilot study in humans.

PURPOSE: To evaluate indirect magnetic resonance lymphangiography (MR-LAG) using interstitial injection of conventional gadolinium contrast (gadoteridol and gadopentetate dimeglumine) for delineating the primary lymphatic drainage of head-and-neck sites. METHODS AND MATERIALS: We performed head-and-neck MR-LAG in 5 healthy volunteers, with injection of dermal and mucosal sites. We evaluated the safety of the procedure, the patterns of enhancement categorized by injection site and nodal level, the time course of enhancement, the optimal concentration and volume of contrast, and the optimal imaging sequence. RESULTS: The worst side effects of interstitial contrast injection were brief, mild pain and swelling at the injected sites that were self-limited. MR-LAG resulted in consistent visualization of the primary lymphatic drainage pattern specific to each injected site, which was reproducible on repeated examinations. The best enhancement was obtained with injection of small volumes (0.3-0.5 mL) of either agent diluted, imaging within 5-15 min of injection, and a three-dimensional fast spoiled gradient echo sequence with magnetization transfer. CONCLUSIONS: We found head-and-neck MR-LAG to be a safe, convenient imaging method that provides functional information about the lymphatic drainage of injected sites. Applied to head-and-neck cancer, it has the potential to identify sites at highest risk of occult metastatic spread for radiotherapy or surgical planning, and possibly to visualize micrometastases.

Adult↗

A quality assurance program for the on-board imagers.

To develop a quality assurance (QA) program for the On-Board Imager (OBI) system and to summarize the results of these QA tests over extended periods from multiple institutions. Both the radiographic and cone-beam computed tomography (CBCT) mode of operation have been evaluated. The QA programs from four institutions have been combined to generate a series of tests for evaluating the performance of the On-Board Imager. The combined QA program consists of three parts: (1) safety and functionality, (2) geometry, and (3) image quality. Safety and functionality tests evaluate the functionality of safety features and the clinical operation of the entire system during the tube warm-up. Geometry QA verifies the geometric accuracy and stability of the OBI/CBCT hardware/software. Image quality QA monitors spatial resolution and contrast sensitivity of the radiographic images. Image quality QA for CBCT includes tests for Hounsfield Unit (HU) linearity, HU uniformity, spatial linearity, and scan slice geometry, in addition. All safety and functionality tests passed on a daily basis. The average accuracy of the OBI isocenter was better than 1.5 mm with a range of variation of less than 1 mm over 8 months. The average accuracy of arm positions in the mechanical geometry QA was better than 1 mm, with a range of variation of less than 1 mm over 8 months. Measurements of other geometry QA tests showed stable results within tolerance throughout the test periods. Radiographic contrast sensitivity ranged between 2.2% and 3.2% and spatial resolution ranged between 1.25 and 1.6 lp/mm. Over four months the CBCT images showed stable spatial linearity, scan slice geometry, contrast resolution (1%; <7 mm disk) and spatial resolution (>6 lp/cm). The HU linearity was within +/-40 HU for all measurements. By combining test methods from multiple institutions, we have developed a comprehensive, yet practical, set of QA tests for the OBI system. Use of the tests over extended periods show that the OBI system has reliable mechanical accuracy and stable image quality. Nevertheless, the tests have been useful in detecting performance deficits in the OBI system that needed recalibration. It is important that all tests are performed on a regular basis.

Equipment Failure Analysis↗

Statistical process control for radiotherapy quality assurance.

Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process.

Humans↗

Monte Carlo Commissioning of Low Energy Electron Radiotherapy Beams using NXEGS Software.

This work is a report on the commissioning of low energy electron beams of a medical linear accelerator for Monte Carlo dose calculation using NXEGS software (NXEGS version 1.0.10.0, NX Medical Software, LLC). A unique feature of NXEGS is automated commissioning, a process whereby a combination of analytic and Monte Carlo methods generates beam models from dosimetric data collected in a water phantom. This study uses NXEGS to commission 6, 9, and 12 MeV electron beams of a Varian Clinac 2100C using three applicators with standard inserts. Central axis depth-dose, primary axis and diagonal beam profiles, and output factors are the measurements necessary for commissioning of the code. We present a comparison of measured dose distributions with the distributions generated by NXEGS, using confidence limits on seven measures of error. We find that confidence limits are typically less than 3% or 3 mm, but increase with increasing source to surface distance (SSD) and depth at or beyond R(50). We also investigate the dependence of NXEGS' performance on the size and composition of data used to commission the program, finding a weak dependence on number of dose profiles in the data set, but finding also that commissioning data need be measured at only two SSDs.

Journal Article↗

Lens dose in MLC-based IMRT treatments of the head and neck.

PURPOSE: The objectives of this work are: (1) to determine typical dose to the lens during step-and-shoot intensity modulated radiotherapy (IMRT) treatments of the head and neck, and (2) to report on the dose calculation accuracy of a commercial inverse planning system in predicting lens dose. METHODS AND MATERIALS: The Corvus inverse treatment planning system (Nomos, Cranberry Township, PA) was used to plan IMRT treatments for patients with head-and-neck cancers in our clinic. Patients were treated on Varian C-series linacs (Varian, Palo Alto, CA) with 4-MV or 6-MV X-rays. A Rando phantom (Alderson Laboratories, Stamford, CT) was specially modified to accommodate 1 x 1 x 1 mm(3) thermoluminescent dosimeters at the position of the lens. The IMRT treatment plans were then delivered to the modified Rando phantom. The thermoluminescent dosimeter measurements were converted to dose and taken as an estimate of the lens dose. A total of 20 cases were used in this study (15 cases with 4 MV and 5 cases with 6 MV). RESULTS: Expressed as a percentage of the prescription dose, the mean dose to the left and right lens for all 4-MV cases was 9.1% (range, 2.0% to 61.3%). For the 6-MV cases, the mean dose to the left and right lens was 12.8% (range, 3.6% to 41.3%). For both the 4-MV and 6-MV cases, the case of maximum dose occurred when the IMRT treatment target included volumes superior to the level of the lens. The field size and number of monitor units did not correlate with the measured lens dose. The only factor of significance affecting lens dose was the inferior-to-superior distance of the target to the lens. For target-lens distance >/=6 mm, the maximum measured lens doses were 5.9% and 9.0% relative to the prescribed dose for the 4-MV and 6-MV beams, respectively. These data are similar to those observed in conventional head-and-neck treatments. For all cases, the difference between the dose measured and that predicted by Corvus was less than 2% and 4% of the dose prescribed to the gross tumor volume for the 4-MV and 6-MV cases, respectively. CONCLUSION: In IMRT, factors such as leaf leakage and number of monitor units play a secondary role and are not more significant than what is observed in conventional head-and-neck treatment when the lens is shielded by the collimator jaws. The target-lens distance is the parameter that affects the lens dose most strongly. For cases where the tumor is at or above the level of the lens, the lens dose can amount to an appreciable fraction of the prescription dose. To keep the lens dose to a minimum, noncoplanar beams that enter or exit into the lens should not be used.

Calibration↗