PubMed Health⌕ Search

Biomedical subjects

Tohoru Takeda

Publications and source records attributed to Tohoru Takeda.

13 recordsLinked to original sources

Sequential evaluation of hepatic functional reserve by 99mTechnetium-galactosyl human serum albumin scintigraphy after proton beam therapy: a report of three cases and a review of the literatures.

The treatment strategy for malignant liver tumors should be appropriately determined because post-treatment quality of life greatly depends on the patients' residual hepatic function. In this report, we present three patients with malignant liver tumors treated by proton beam therapy in whom pre- and post-therapeutic hepatic functional reserves were evaluated sequentially for more than a year by 99mTechnetium-galactosyl human serum albumin (99mTc-GSA) scintigraphy. All three patients exhibited the distinctive time course of 99mTc-GSA uptake efficiency, which suggested a transient decline in the ratio of liver activity to heart and liver activity at 15 minutes (LHL15) 3-6 months after proton beam therapy. This change was not in parallel with that expected from a functioning normal liver tissue volume. In a year after proton beam therapy, LHL15 recovered nearly to the pre-treatment level in all three patients. Our observations may be related to the up-regulation of receptor-mediated 99mTc-GSA uptake during hepatic regeneration after proton beam therapy.

Aged↗

High-energy phase-contrast X-ray imaging using a two-crystal X-ray interferometer.

To broaden the scope of phase-contrast X-ray imaging in biomedical applications, the energy of X-rays in a large-area imaging system using a two-crystal X-ray interferometer has been increased from 17.7 keV to 35 keV. The use of higher-energy X-rays makes it possible to observe larger samples having greater variation in density within shorter measurement periods, at higher spatial resolution, and at lower X-ray doses. After optimizing the imaging system for 35 keV X-rays, a 25 mm x 30 mm interference pattern with 50% visibility was generated at the Photon Factory. The system's capabilities are demonstrated by this pattern and a high-quality three-dimensional image of a rat heart.

Animals↗

Coherence-contrast x-ray imaging based on x-ray interferometry.

Coherence-contrast x-ray imaging--which detects changes in the degree of coherence caused by the placement of a sample in an x-ray interferometer--was developed for biomedical applications. Because the technique's sensitivity depends on the density gradient in the sample, it is particularly suitable for observing biomedical samples with large density differences, such as samples that include both biological soft tissue and bone. A measurement principle and method of this technique are described, and a fine coherence-contrast image of a mouse leg is given as an example result.

Animals↗

Mismatch between gallium-67 uptake and CT findings in a case of pulmonary alveolar proteinosis.

Gallium-67 citrate (67Ga) scintigraphy has been used as an indicator of activity of diffuse interstitial lung diseases. However, little has been mentioned in pulmonary alveolar proteinosis (PAP). Here we present a 53-year-old man with PAP showing patchy 67Ga uptake by single photon emission computed tomography (SPECT). Interestingly, the strong 67Ga uptake was observed in areas where ground-glass opacities were faint on chest CT. The uptake persisted after whole-lung lavage while the ground-glass opacity improved markedly. Although the precise mechanism of 67Ga uptake remains unclear, 67Ga SPECT findings may reflect the different pathological condition of PAP than that shown by CT.

Citrates↗

Abnormal retention of 99mTc-TF in a hamster model of cardiomyopathy analyzed by 99mTc-TF and 125I-BMIPP autoradiography.

OBJECTIVE: Enhanced washout of 99mTc-tetrofosmin (TF) has been reported in patients with hypertrophic cardiomyopathy (HCM). Here, using quantitative dual-autoradiography, the relationship between TF retention abnormality and metabolism depicted by 125I-BMIPP uptake was investigated quantitatively in a hamster model of cardiomyopathy. METHODS AND RESULTS: Early and delayed TF images were obtained at 5 min (7 cardiomyopathic and 5 normal hamsters) and 60 min (8 cardiomyopathic and 5 normal hamsters) after injection, respectively. BMIPP image was obtained 5 min after injection. Five cardiomyopathic and 5 normal hamsters were evaluated histologically. Percent uptake of TF and BMIPP in the heart was measured by an auto-well counter. The left ventricular wall was divided into 12 segments, and the relative regional uptake of TF and BMIPP was measured for each segment. Heterogeneity of radioactive distribution was determined by the standard deviation (SD) of radioactive counts in the left ventricular wall on autoradiogram. The uptake of early TF, delayed TF, and BMIPP in cardiomyopathic hamsters was 8.8%, 20.3%, and 25.3% lower than that in normal hamsters, p < 0.05, p < 0.01, and p < 0.001, respectively. In normal hamsters, distribution of radioactivity in all images was homogeneous, and the SD values were about 13. In cardiomyopathic hamsters, heterogeneous distribution was observed on all images, and the degree of heterogeneity was marked on delayed TF and BMIPP images. The SD was 19.7 +/- 1.2 for early TF image, 25.5 +/- 1.4 for delayed TF image, and 31.7 +/- 2.4 for BMIPP image, respectively. A weak linear correlation was observed between the relative regional uptake of the delayed TF and BMIPP in cardiomyopathic hamsters (r = 0.57). Electron microscopy demonstrated ultra-structural changes in mitochondria of cardiomyopathic hamsters. CONCLUSION: Degree of retention abnormality on delayed TF image corresponded to the metabolic abnormality, probably due to mitochondrial dysfunction, depicted on BMIPP imaging.

Animals↗

Shaken baby syndrome manifesting as chronic subdural hematoma: importance of single photon emission computed tomography for treatment indications--case report.

A boy with shaken baby syndrome first presented at age 3 months with acute subdural hematoma (SDH) and was treated by subdural tapping at a local hospital. Chronic SDH was identified at a rehabilitation center at age 19 months. The chronic SDH appeared to have developed within the preceding 16 months. His physical and mental development was already delayed. Magnetic resonance (MR) imaging revealed a 20-mm thick right chronic SDH with midline shift and small bilateral subdural effusions. The chronic SDH had compressed the right cerebral hemisphere. MR imaging also disclosed bilateral cerebral atrophy. 99mTc-ethylcysteinate dimer single photon emission computed tomography (SPECT) revealed decreased cerebral blood flow (CBF) in the non-hematoma hemisphere, although CBF is said to decrease on the chronic SDH side, especially if midline shift is present. Burr hole craniotomy with external drainage was performed, but the patient showed no change in CBF postoperatively, although the volume of hematoma decreased. The patient was clinically unchanged immediately after the operation. In this case, SPECT measurement of CBF was important in evaluating the pathophysiology of the delays in physical and mental growth. Atrophy of the bilateral hemispheres was the major mechanism in the decreased CBF, not the compression by chronic SDH. MR imaging and SPECT can determine the surgical indications for chronic SDH in patients with cortical atrophy.

Atrophy↗

Enhanced washout of 99mTc-tetrofosmin in hypertrophic cardiomyopathy: quantitative comparisons with regional 123I-BMIPP uptake and wall thickness determined by MRI.

The diagnostic value of technetium-99m tetrofosmin (TF) washout in hypertrophic cardiomyopathy (HCM) was examined by investigating its relation to the metabolic abnormality depicted by iodine-123 beta-methyl- p-iodophenylpentadecanoic acid (BMIPP) uptake and the left ventricular (LV) myocardial wall thickness as measured by magnetic resonance imaging (MRI). TF washout was evaluated in 31 patients with HCM and 23 normal control subjects using 30-min (early) and 3-h (delayed) TF single-photon emission tomography images. The LV myocardial wall was divided into 19 segments and the percentage TF washout, regional BMIPP uptake and LV wall thickness were measured in each segment. Mean TF washout in the patients with HCM was significantly faster than that in normal control subjects (23.7+/-5.7 vs 13.4+/-4.1, P<0.0001). In the patients with HCM, TF washout showed an excellent correlation with MRI wall thickness ( r=0.82, P<0.0001) and a good inverse correlation with regional BMIPP uptake ( r=-0.72, P<0.0001). In addition, a good linear correlation was observed between TF uptake and MRI wall thickness in the 19 regional segments. In conclusion, the degree of TF washout corresponds well with the severity of myocardial wall thickness and the degree of metabolic abnormality in patients with HCM. These results suggest that enhanced TF washout might provide additional clinical information regarding metabolic alterations in HCM.

Adult↗

A case of delusional disorder, somatic type with remarkable improvement of clinical symptoms and single photon emission computed tomograpy findings following modified electroconvulsive therapy.

A 72-year-old male with delusional disorder, somatic type (DDST), was treated by modified electroconvulsive therapy (mECT). His somatic delusions were completely resolved by mECT. In parallel with the improvement of his clinical symptoms, we observed an improvement of regional cerebral blood flow (rCBF) in the left temporal and parietal lobes shown by the single photon emission computed tomograpy (SPECT). This study appears to support the utility of mECT for somatic delusions in elderly patients and suggests possible association of the dysfunction in the left temporal and parietal lobes with manifestation of the somatic delusion of the patient.

Aged↗

Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer.

Large-area (25 x 20 mm) phase-contrast X-ray imaging was attained by using a skew-symmetric two-crystal X-ray interferometer. The sub-nrad angular control required to operate the X-ray interferometer was achieved with a sleeve bearing and a feedback-positioning system. As a demonstration, measurements of a phase map of a rat's liver and a phase-contrast tomographic three-dimensional image of a piece of a rabbit's liver were performed at the Photon Factory using 0.07 nm synchrotron radiation X-rays.

Animals↗

Vessel imaging by interferometric phase-contrast X-ray technique.

BACKGROUND: Phase-contrast x-ray imaging using an x-ray interferometer has great potential to reveal the structures inside soft tissues, because the sensitivity of this method to hydrogen, carbon, nitrogen, and oxygen is approximately 1000 times higher than that of the absorption-contrast x-ray method. Imaging of vessels is very important to understand the vascular distribution of organs and tumors, so the possibility of selective angiography based on phase contrast is examined with a physiological material composed of low-atomic-number elements. METHODS AND RESULTS: Phase-contrast x-ray imaging was performed with a synchrotron x-ray source. Differences in refractive index, ddelta, of physiological saline, lactated Ringer's solution, 5% glucose, artificial blood such as pyridoxylated hemoglobin-polyoxyethylene conjugate, and perfluorotributylamine were measured. Because the ddelta of physiological saline has highest contrast, it was used for the phase-contrast x-ray imaging of vessel, and this was compared with absorption-contrast x-ray images. Vessels >0.03 mm in diameter of excised liver from rats and a rabbit were revealed clearly in phase-contrast x-ray imaging, whereas the vessel could not be revealed at all by the absorption-contrast x-ray image. Absorption-contrast x-ray images with iodine microspheres depicted only portal veins >0.1 mm in diameter with nearly the same x-ray dose as the present phase-contrast x-ray imaging. CONCLUSIONS: Phase-contrast x-ray imaging explored clear depiction of the vessels using physiological saline with small doses of x-rays.

Angiography↗

[Phase-contrast x-ray imaging with x-ray interferometer for medical applications].

Phase-contrast x-ray imaging with x-ray interferometer can depict the minute difference within the biological object, and its sensitivity is about 1000 times higher than that of absorption-contrast method. For biomedical use of this technique, a large monolithic x-ray interferometer and 2 crystal interferometer having a field of view with 25 mm x 25 mm is being developed. Phase-contrast x-ray CT could reveal detail structures within tumor and surrounded tissue, and the vessel imaging of rat liver is also possible using physiological saline at 17.7 keV x-ray energy. Recently, human breast tissues were imaged at 35 keV and the contrast of image was much better than usual absorption contrast x-ray image obtained at 17.7 keV energy.

Animals↗

Solitary hot spots in the ribs on bone scan: value of thin-section reformatted computed tomography to exclude radiography-negative fractures.

PURPOSE: The purpose of this study was to classify solitary, scintigraphy-positive and radiography-negative rib lesions and to clarify the features of rib fractures by using thin-section reformatted helical computed tomography (CT). METHODS: Forty-seven patients whose whole-body bone scans showed a solitary hot spot in a rib as their first abnormal scintigraphic finding and whose plain radiograph showed negative or indeterminate results were examined by thin-section reformatted CT. Final diagnosis was based on follow-up over a 20-month period. RESULTS: The final diagnosis included 17 cases of fractures where CT findings were fracture line, focal sclerosis, and callus formation. Fourteen ribs demonstrated intramedullary, focal osteosclerosis, and 8 ribs did not demonstrate any abnormalities. Four metastatic lesions appeared as intramedullary mixture of osteolysis and osteosclerosis, or bone destruction. Four intramedullary lesions with cystic appearance remained unchanged. CONCLUSIONS: Thin-section reformatted helical CT delineated minute, radiographically occult fractures of the rib. Excluding fractures, helical CT can avoid further unnecessary examinations.

Adult↗