A method for personal expertise-independent evaluation of image resolution in scanning electron microscopy.

The two conventional methods currently employed for the evaluation of image resolution in scanning electron microscopy are the gap method and a fast Fourier transform (FFT) method. These can be highly dependent on personal expertise on the distinction between signal information and noise contained in a micrograph. Hence, the present paper proposes an alternative method (referred to as a contrast-to-gradient (CG) method) that can determine the image resolution of a micrograph without requiring personal expertise on the judgment of noise. The image resolution in the CG method is defined as a weighted harmonic mean of the local resolution, which is proportional to the quotient of the threshold contrast divided by the local gradient. The local gradient is calculated from the quadratic function that best fits the local pixel intensities over 5 x 5 pixels. It has been shown that the CG method, compared with the FFT method, has a broader range of applications for various types of images, such as low-contrast, noise-containing, filter-processed, highly directional, and quasi-periodic feature images.

Journal Article↗

Comparison in spatial spreads of secondary electron information between scanning ion and scanning electron microscopy.

Monte Carlo simulations have been carried out to compare the spatial spreads of secondary electron (SE) information in scanning ion microscopy (SIM) with scanning electron microscopy (SEM). Under Ga ion impacts, the SEs are excited by three kinds of collision-partners, that is, projectile ion, recoiled target atom, and target electron. The latter two partners dominantly contribute to the total SE yield gamma for the materials of low atomic number Z2. For the materials of high Z2, on the other hand, the projectile ions dominantly contribute to gamma. These Z2 dependencies generally cause the gamma yield to decrease with an increasing Z2, in contrast with the SE yield delta under electron impacts. Most of the SEs are produced in the surface layer of about 5lambda in depth (lambda: the mean free path of SEs), as they are independent of the incident probe. Under 30 keV Ga ion impacts, the spatial spread of SE information is roughly as small as 10 nm, decreasing with an increasing Z2. Under 10 keV electron impacts, the SEI excited by the primary electrons has a small spatial spread of about 5lambda, but the SEII excited by the backscattered electrons has a large one of several 10 to several 100 nanometers, decreasing with an increasing Z2. The main cause of a small spread of SE information at ion impact is the short ranges of the projectile ions returning to the surface to escape as backscattered ions, the recoiled target atoms, and the target electrons in collision cascade. The 30 keV Ga-SIM imaging is better than the 10 keV SEM imaging in spatial resolution for the structure/material measurements. Here, zero-size probes are assumed.

Journal Article↗