A comparison of prostate IMRT and helical tomotherapy class solutions.

The purpose of this study was to assess a variety of potential IMRT class solutions as compared to a helical tomotherapy (HT) class solution for localized prostate cancer. Target and critical structures were contoured on 10 prostate cancer patient CT datasets. HT treatment plans were compared to four different IMRT approaches by paired t-tests. HT prostate planning generally provided treatment plans with excellent target homogeneity and favorable critical structure sparing when compared to conventional IMRT.

Humans↗

Comparative planning evaluation of intensity-modulated radiotherapy techniques for complex lung cancer cases.

BACKGROUND AND PURPOSE: Lung cancer treatment can be one of the most challenging fields in radiotherapy. The aim of the present study was to compare different modalities of radiation delivery based on a balanced scoring scheme for target coverage and normal tissue avoidance. PATIENTS AND METHODS: Treatment plans were developed for 15 patients with stage III inoperable non-small cell lung cancer using 3D conformal technique and intensity-modulated radiotherapy (IMRT). Elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate PTV2 and 1cm margin around elective nodes for PTV1 resulting in PTV1 volumes larger than 1000 cm(3) in 13 of the 15 patients. 3D conformal and IMRT plans were generated on a commercial treatment planning system (TheraPlan Plus, Nucletron) with various combinations of beam energies and gantry angles. A 'dose quality factor' (DQF) was introduced to correlate the plan quality with patient specific parameters. RESULTS: A good correlation was found between the quality of the plans and the overlap between PTV1 and lungs. The patient feature factor (PFF), which is a product of several pertinent characteristics, was introduced to facilitate the choice of a particular technique for a particular patient. CONCLUSIONS: This approach may allow the evaluation of different treatment options prior to actual planning, subject to validation in larger prospective data sets.

Carcinoma, Non-Small-Cell Lung↗

The response of prototype plane-parallel ionization chambers in small megavoltage x-ray fields.

Accurate small-field dosimetry has become important with the use of multiple small fields in modern radiotherapy treatments such as IMRT and stereotactic radiosurgery. In this study, we investigate the response of a set of prototype plane-parallel ionization chambers, based upon the Exradin T11 chamber, with active volume diameters of 2, 4, 10, and 20 mm, exposed to 6 MV stereotactic radiotherapy x-ray fields. Our goal was to assess their usefulness for accurate small x-ray field dose measurements. The relative ionization response was measured in circular fields (0.5 to 4 cm diameter) as compared to a 10 x 10 cm2 reference field. A large discrepancy (approximately 40%) was found between the relative response in the smallest plane-parallel chamber and other small volume dosimeters (radiochromic film, micro-metal-oxide-semiconductor field-effect transistor and diode) used for comparison. Monte Carlo BEAMnrc simulations were used to simulate the experimental setup in order to investigate the cause of the under-response and to calculate appropriate correction factors that could be applied to experimental measurements. It was found that in small fields, the air cavity of these custom-made research chambers perturbed the secondary electron fluence profile significantly, resulting in decreased fluence within the active volume, which in turn produces a chamber under-response. It is demonstrated that a large correction to the p(fl) correction factor would be required to improve dosimetric accuracy in small fields, and that these factors could be derived using Monte Carlo simulations.

Dose-Response Relationship, Radiation↗

Correlation of 3D-planned and measured dosimetry of photon and electron craniospinal radiation in a pediatric anthropomorphic phantom.

BACKGROUND AND PURPOSE: Improved radiotherapy techniques in pediatric craniospinal therapy (CSRT) strive to reduce risks of late morbidity. Using a pediatric anthropomorphic phantom, this research correlated measured target and normal tissue dose to that predicted from a 3D planning system (3D-RTP). PATIENTS AND METHODS: A pediatric anthropomorphic phantom was planned following French Society of Pediatric Oncology (SFOP) protocols. Thermoluminescent detectors (TLDs) were used to perform dosimetric measurements during treatment. 4 and 6MV photon fields with multi leaf collimation (MLC) or custom blocks were compared to 3D-RTP computer (ADAC Pinnacle) predictions for cranial fields. Spinal dosimetry was studied using photons (4 and 6MV) and electrons (9 and 12MeV). RESULTS: 3D-RTP predictions generally concurred with dose received in cranial and spinal sites. The measured dose was over-predicted significantly by the 3D-RTP in the anterior cranial fossa. Normal tissue doses were reduced when treating the spine using megavoltage electron beams instead of photons. CONCLUSIONS: Treating the spinal field with electrons minimises the risk of pulmonary sequelae, however electron energy selection is critical to achieve adequate spinal field coverage. Despite adhering to a major trial protocol guideline, dose at the floor of the anterior cranial fossa remains a potential clinical problem and 3D-RTP do not predict this well.

Anthropometry↗

Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy.

Loose helical delivery is a potential solution to account for respiration-driven tumour motion in helical tomotherapy (HT). In this approach, a treatment is divided into a set of interlaced 'loose' helices commencing at different gantry angles. Each loose helix covers the entire target length in one gantry rotation during a single breath-hold. The dosimetric characteristics of loose helical delivery were investigated by delivering a 6 MV photon beam in a HT-like manner. Multiple scenarios of conventional 'tight' HT and loose helical deliveries were modelled in treatment planning software, and carried out experimentally with Kodak EDR2 film. The advantage of loose helical delivery lies in its ability to produce a more homogeneous dose distribution by eliminating the 'thread' effect-an inherent characteristic of HT, which results in dose modulations away from the axis of gantry rotation. However, loose helical delivery was also subjected to undesirable dose modulations in the direction of couch motion (termed 'beating' effect), when the ratio between the number of beam projections per gantry rotation (n) and pitch factor (p) was a non-integer. The magnitude of dose modulations decreased with an increasing n/p ratio. The results suggest that for the current HT unit (n = 51), dose modulations could be kept under 5% by selecting a pitch factor smaller than 7. A pitch factor of this magnitude should be able to treat a target up to 30 cm in length. Loose helical delivery should increase the total session time only by a factor of 2, while the planning time should stay the same since the total number of beam projections remains unchanged. Considering its dosimetric advantage and clinical practicality, loose helical delivery is a promising solution for the future HT treatments of respiration-driven targets.

Body Burden↗

Tomotherapy planning of small brain tumours.

Helical tomotherapy (HT) combines a rotating intensity modulated fan beam with integrated CT imaging for high precision radiotherapy. HT plans for 12 patients with small brain tumours were compared with five other radiotherapy techniques. Proton techniques gave overall the best results, while HT was shown to produce better target dose uniformity (average SD=1.3%) and kept irradiation of organs at risk as good as other photon methods.

Adenoma↗

A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators.

PURPOSE: The evolution of three-dimensional conformal radiation treatment has led to the use of multileaf collimators (MLCs) in intensity-modulated radiation therapy (IMRT) and other treatment techniques to increase the conformity of the dose distribution. A new quality assurance (QA) phantom has been designed to check the handling of MLC settings in treatment planning and delivery. METHODS AND MATERIALS: The phantom consists of a Perspex block with stepped edges that can be rotated in all planes. The design allows for the assessment of several MLC and micro-MLC types from various manufacturers, and is therefore applicable to most radiation therapy institutions employing MLCs. The phantom is computed tomography (CT) scanned as is a patient, and QA assessments can be made of field edge display for a variety of shapes and orientations on both radiation treatment planning systems (RTPS) and computed tomography simulators. RESULTS: The dimensions of the phantom were verified to be physically correct within an uncertainty range of 0-0.7 mm. Errors in leaf position larger than 1 mm were easily identified by multiple observers. CONCLUSIONS: The MLC geometry phantom is a useful tool in the QA of radiation therapy with application to RTPS, CT simulators, and virtual simulation packages with MLC display capabilities.

Algorithms↗

Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry.

In many medical procedures where accurate radiation dose measurements are needed, the variation of detector response with x-ray energy is of concern. The response of LiF:Mg,Cu,P TLDs to a range of x-ray energies was analysed in monoenergetic (synchrotron), diagnostic and therapy radiation beams with the aim of implementing this dosimeter into clinical practice where existing dosimetry techniques are limited due to lack of sensitivity or tissue equivalence (e.g. neonatal radiography, mammography and brachytherapy). LiF:Mg,Cu,P TLDs in different forms from two manufacturers (MCP-N: TLD Poland, GR200: SDDML China) were irradiated using x-ray beams covering 10 keV to 18 MVp. Dose readings were compared with an ionization chamber. The effect of different TLD types and annealing cycles on clinical utility was investigated. The measured energy response of LiF:Mg,Cu,P TLDs was fit to a simple model devised by Kron et al (1998 Phys. Med. Biol. 43 3235-59) to describe the variation of TLD response with x-ray energy. If TLDs are handled as recommended in the present paper, the energy response of LiF:Mg,Cu,P deviates by a maximum of 15% from unity and agrees with the model to within 5% or experimental uncertainty between 15 keV and 10 MeV. LiF:Mg,Cu,P TLDs of all forms have consistent and superior energy response compared to the standard material LiF:Mg,Ti and are therefore suitable for a wide range of applications in diagnostic radiology and radiotherapy.

Brachytherapy↗

Interpolation and extrapolation of dose measurements with different detector sizes to improve the spatial resolution of radiotherapy dosimetry as demonstrated for helical tomotherapy.

A new technique for intensity modulated radiation therapy (IMRT) delivery is helical tomotherapy (HT). Like most IMRT delivery methods, HT utilizes many small fields as part of the treatment plan, which can be difficult to characterize. A novel technique for small field characterization, based on inter- and extrapolation of ion chamber readings, is presented in the context of HT. As a fan beam is characterized by its thickness and output factor, plane parallel chambers with different active volumes were used to scan the fan beam profiles. The fan beam thickness (FBT) can be determined from the thickness measured with the chamber by extrapolating to an infinitesimally small chamber size. The effective output was derived from the integral under the dose profile divided by the FBT. This was done for five FBTs and demonstrated a sharp fall off in dose when the FBT decreased below 8 mm. Similar techniques can be applied to other IMRT techniques to improve the characterization of various beam parameters.

Calibration↗

Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy.

Lung cancer treatment is one of the most challenging fields in radiotherapy. The aim of the present study was to investigate what role helical tomotherapy (HT), a novel approach to the delivery of highly conformal dose distributions using intensity-modulated radiation fan beams, can play in difficult cases with large target volumes typical for many of these patients. Tomotherapy plans were developed for 15 patients with stage III inoperable non-small-cell lung cancer. While not necessarily clinically indicated, elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate primary planning target volume (PTV2) and 1 cm margin around elective nodes for secondary planning target volume (PTV1) resulting in PTV1 volumes larger than 1000 cm3 in 13 of the 15 patients. Tomotherapy plans were created using an inverse treatment planning system (TomoTherapy Inc.) based on superposition/convolution dose calculation for a fan beam thickness of 25 mm and a pitch factor between 0.3 and 0.8. For comparison, plans were created using an intensity-modulated radiation therapy (IMRT) approach planned on a commercial treatment planning system (TheraplanPlus, Nucletron). Tomotherapy delivery times for the large target volumes were estimated to be between 4 and 19 min. Using a prescribed dose of 60 Gy to PTV2 and 46 Gy to PTV1, the mean lung dose was 23.8+/-4.6 Gy. A 'dose quality factor' was introduced to correlate the plan outcome with patient specific parameters. A good correlation was found between the quality of the HT plans and the IMRT plans with HT being slightly better in most cases. The overlap between lung and PTV was found to be a good indicator of plan quality for HT. The mean lung dose was found to increase by approximately 0.9 Gy per percent overlap volume. Helical tomotherapy planning resulted in highly conformal dose distributions. It allowed easy achievement of two different dose levels in the target simultaneously. As the overlap between PTV and lung volume is a major predictor of mean lung dose, future work will be directed to control of margins. Work is underway to investigate the possibility of breath-hold techniques for tomotherapy delivery to facilitate this aim.

Carcinoma, Non-Small-Cell Lung↗

'When measurements mean action' decision models for portal image review to eliminate systematic set-up errors.

The aim of the present paper is to evaluate how the use of decision models in the review of portal images can eliminate systematic set-up errors during conformal therapy. Sixteen patients undergoing four-field irradiation of prostate cancer have had daily portal images obtained during the first two treatment weeks and weekly thereafter. The magnitude of random and systematic variations has been calculated by comparison of the portal image with the reference simulator images using the two-dimensional decision model embodied in the Hotelling's evaluation process (HEP). Random day-to-day set-up variation was small in this group of patients. Systematic errors were, however, common. In 15 of 16 patients, one or more errors of >2 mm were diagnosed at some stage during treatment. Sixteen of the 23 errors were between 2 and 4 mm. Although there were examples of oversensitivity of the HEP in three cases, and one instance of undersensitivity, the HEP proved highly sensitive to the small (2-4 mm) systematic errors that must be eliminated during high precision radiotherapy. The HEP has proven valuable in diagnosing very small (<4 mm) errors. When combined with the potential for rapid diagnosis of larger (>4 mm) systematic errors using one-dimensional decision models, HEP can eliminate the majority of systematic errors during the first 2 treatment weeks.

Aged↗

Asymmetric fan beams (AFB) for improvement of the craniocaudal dose distribution in helical tomotherapy delivery.

Helical tomotherapy (HT) is a novel radiotherapy technique that utilizes intensity modulated fan beams that deliver highly conformal dose distributions in a helical beam trajectory. The most significant limitation in dose delivery with a constant fan beam thickness (FBT) is the penumbra width of the dose distribution in the craniocaudal direction, which is equivalent to the FBT. We propose to employ a half-blocked fan beam at start and stop location to reduce the penumbra width by half. By opening the jaw slowly during the helical delivery until the desired FBT is achieved it is possible to create a sharper edge in the superior and inferior direction from the target. The technique was studied using a tomotherapy beam model implemented on a commercial treatment planning system (Theraplan Plus V3.0). It was demonstrated that the dose distribution delivered using a 25 mm fan beam can be improved significantly, to reduce the dose to normal structures located superiorly and inferiorly of the target. Dosimetry for this technique is straightforward down to a FBT of 15 mm and implementation should be simple as no changes in couch movement are required compared to a standard HT delivery. We conclude that the use of asymmetric collimated fan beams for the start and stop of the helical tomotherapeutic dose delivery has the potential of significantly improving the dose distribution in helical tomotherapy.

Algorithms↗

Multicentre dosimetric comparison of photon-junctioning techniques in head and neck radiotherapy.

Because many head and neck radiotherapy treatment techniques rely on a junction between X-ray fields, it was the aim of the present study to investigate the use of different junctioning techniques and the affect on the dose across the junction. Techniques in use at nine radiotherapy centres in Australia were investigated using thermoluminescence dosimetry (TLD). The techniques could broadly be divided into two groups: (i) use of the light field to match the fields after moving the patient; and (ii) use of asymmetric collimation to create a single isocentre located in the junction. The mean dose at the junction and its reproducibility was studied in five consecutive treatments in each centre using 25 TLD chips placed throughout the junction in an anthropomorphic phantom. There was a tendency for the mono-isocentric technique to deliver a lower, more accurate mean dose at the junction (Group I: 1.22 Gy (n = 8) vs Group II: 0.96 Gy (n = 5) for 1 Gy planned, some centres contributed to both technique) with greater reproducibility (Group I: 9.6%, Group II: 5.1% of the mean dose). We conclude that a mono-isocentric treatment technique has the potential to deliver a more accurate and reproducible dose distribution at the field junction of photon beams in head and neck treatment.

Data Collection↗

A flattening filter for brachytherapy skin irradiation.

Radioactive sources in close contact offer an alternative to superficial radiation in the treatment of skin lesions. A flattening filter was designed for a lead surface applicator to improve the skin dose distribution of a high dose rate (HDR) brachytherapy unit (Nucletron). At three heights from the opening (10, 15 and 25 mm) of the cylindrical applicator, the 192Ir source can be driven into the centre of the applicator. Thin sheets of lead foil (0.2 mm) were cut into circular shapes and placed in the opening to build a cylindrical cone that acts as a flattening filter. The shape of the cone was optimized in an iterative process using a spreadsheet and the resulting dose distribution under the applicator was determined using radiosensitive film. The use of the filter improved the dose distribution in a plane perpendicular to the beam axis to be within +/- 5% of the central axis dose. The present applicator and flattening filter together with an HDR brachytherapy unit offer an alternative for skin irradiation where a superficial unit is not available or will be replaced with a more flexible device. As the depth dose characteristics can be modified using different source-to-surface distances, the dose throughout the patient's skin can be shaped as desired by the radiation oncologist using a compensator design type approach.

Brachytherapy↗

Optimal flattening filter shape of a surface brachytherapy applicator.

As an alternative to standard treatment of superficial lesions with surgery and/or superficial/orthovoltage x-ray irradiation, radioactive moulds can be used. However, close proximity of the source to the treatment region leads to significant dose inhomogeneities in the tissue. Analytical and fast numerical methods have been developed that can calculate a corresponding flattening filter that evens out the dose distribution at the surface. Monte Carlo transport calculations were used to enable accurate treatment of the transport through the geometry. It was found that the use of pre-calculated transport parameters like dependence of the attenuation coefficient and scattering with depth is required for fast calculation of the flattening filter shape. Only 1-2 iterations were needed for a successful convergence to the filter shape that flattens out the dose distribution at the surface to within 1%. The developed methods are very general and could be applied with some minor modifications to other problems, where shaping of the irradiation field is required.

Algorithms↗

Dosimetric intercomparison for two Australasian clinical trials using an anthropomorphic phantom.

INTRODUCTION: Many different factors can affect the accurate delivery of dose to the clinical target volume in radiotherapy. This is particularly important in the context of multicenter clinical trials where different equipment and techniques may be used for supposedly identical treatments. A dosimetric intercomparison employing an anthropomorphic phantom (level III dosimetric intercomparison) can be used to check many of the factors that could affect treatment by mimicking the radiotherapy pathway of a patient as closely as possible. METHODS AND MATERIALS: An anthropomorphic phantom (ART) was taken to 18 radiotherapy centers in Australia and New Zealand and treated for two different treatment scenarios based on current clinical trials of the Trans-Tasman Radiation Oncology Group (TROG): a two-field treatment of a carcinoma of the tonsil (TROG 91.01), and a four-field prostate treatment (TROG 96.01). The dose distribution was assessed in two consecutive treatments using thermoluminescence dosimeters (TLDs) placed throughout the target volume and in "critical" structures such as the lens of the eye or the rectum. The study also included a check of absolute dose calibration in a slab phantom (level I dosimetric intercomparison). The influence of a variety of treatment parameters on the dose homogeneity in the target and the measured dose in the target and the critical organs was evaluated. RESULTS: The dose measurements confirmed that in all participating centers the correct dose was delivered to the ICRU reference point (tonsil: 99.8 +/- 2.3%; prostate: 100.9 +/- 1.9% [1 SD]). Also the absolute dose calibration and the mean dose in the target volume were within the specified action levels of plus minus 5% for all participating centers. No influence of shielding, beam modifiers, beam weighting, treatment planning approach (CT, 2D, 3D), and type of equipment used on the dose in the target and its homogeneity could be demonstrated. However, treatment technique and energy used influenced the dose to the critical organs. It was shown that the interpretation of results could be improved by including two complementary treatment scenarios and a level I intercomparison with the level III dosimetric intercomparison. CONCLUSION: The study demonstrated the feasibility of a level III dosimetric intercomparison service at a cost of approximately $1000(US) per center in Australasia. It confirmed that the dose delivered by all participating centers was as intended in the two treatment scenarios chosen. While this provides reassurance to the oncology community and the general public, the service must be extended to all centers and other potentially more complex treatment scenarios. The present study has built the foundation for this by establishing a baseline and action levels and suggesting improvements in phantom design which will be included in future TROG quality assurance exercises.

Australia↗