PubMed Health⌕ Search

Biomedical subjects

Tommaso Lupattelli

Publications and source records attributed to Tommaso Lupattelli.

9 recordsLinked to original sources

Trisacryl gelatin microspheres versus polyvinyl alcohol particles in the preoperative embolization of bone neoplasms.

The aim of this study was to compare the efficacy of trisacryl gelatin microspheres versus polyvinyl alcohol particles (PVA) in the preoperative embolization of bone neoplasms, on the basis of intraoperative blood loss quantified by the differences in preoperative and postoperative hematic levels of hemoglobin, hematocrit and erythrocytes count. From January 1997 to December 2002, preoperative embolization of bone tumors (either primary or secondary) was carried out in 49 patients (age range 12/78), 20 of whom were treated with trysacril gelatin microspheres (group A) and 29 with PVA particles (group B). The delay between embolization and surgery ranged from 1 to 13 days in group A and 1 to 4 days in group B. As used in international protocols, we considered hematic levels of hemoglobin, hematocrit and erythrocytes count for the measurement of intraoperative blood loss then the differences in pre- and postoperative levels were used as statistical comparative parameters. We compared the values of patients treated with embospheres (n = 10) and PVA (n = 18) alone, and patients treated with (group A = 10; group B = 11) versus patients treated without other additional embolic materials in each group (group A = 10; group B = 18). According to the Student's t-test ( p < 0.05), the difference of hematic parameters between patients treated by embospheres and PVA alone were significant; otherwise there was no significant difference between patients treated with only one embolic material (embospheres and PVA) versus those treated with other additional embolic agents in each group. The patients treated with microspheres had a minor quantification of intraoperative blood loss compared to those who received PVA particles. Furthermore, they had a minor increase of bleeding related to the delay time between embolization and surgery. The use of additional embolic material did not improve the efficacy of the procedure in either group of patients.

Acrylic Resins↗

Increased brain apparent diffusion coefficient in tuberous sclerosis.

PURPOSE: To evaluate the water diffusivity of normal-appearing white matter (NAWM) in patients with tuberous sclerosis complex compared with that in control subjects. MATERIALS AND METHODS: Diffusion and conventional magnetic resonance (MR) imaging examinations were performed in 18 patients with clinically established tuberous sclerosis complex (10 male and eight female patients; mean age, 20.1 years; range, 12-30 years), as well as in 18 age-matched control subjects (nine male and nine female; mean age, 20.2 years; range, 11-28 years). Apparent diffusion coefficients (ADCs) were generated, and small elliptic regions of interest were manually placed both in perilesional NAWM and in six anatomic locations of NAWM remote from hamartomatous lesions. Perilesional ADCs were compared with those at the same anatomic site on the contralateral side of the brain (generalized linear regression analysis). ADCs from the predetermined sites in patients were compared with those in control subjects (generalized linear regression analysis). RESULTS: Supratentorial ADCs were higher in patients with tuberous sclerosis complex than in control subjects, and statistically significant differences were observed in the occipital white matter, frontal white matter, centrum semiovale, parietal white matter, and corona radiata (for each location, P <.001). Significant increases were also seen in the perilesional NAWM compared with NAWM at the same anatomic locations on the contralateral side (P <.001). Infratentorial ADCs were normal. CONCLUSION: Significant ADC increases were measured in the supratentorial NAWM.

Adolescent↗

Nonoperative management of iatrogenic lesions of celiac branches by using transcatheter arterial embolization.

We present our experience in the nonoperative management of iatrogenic lesions of celiac branches by using transcatheter arterial embolization. We treated 6 pseudoaneurysms (5 intrahepatic and 1 of the gastroduodenal artery), 6 vessel lacerations (1 common hepatic artery, 1 right hepatic artery, 1 gastroduodenal artery, 2 pancreatoduodenal, 1 polar intrasplenic artery), 1 arterioportal fistula, and 1 arteriobiliary fistula; all the bleeding lesions were secondary to surgical, endoscopic, or interventional radiologic procedures.

Adult↗

Axillary artery access for interventional procedures.

PURPOSE: To evaluate axillary artery access for the interventional treatment of carotid or splanchnic arteries that have angulated takeoff or complex anatomy when larger catheters (up to 9 F) are needed. TECHNIQUE: The axillary artery approach was used to treat the left internal carotid artery (ICA) in 3 patients (2 angulated takeoffs and 1 bovine arch) and a celiac axis aneurysm. An 8-F, 45-cm-long introducer sheath was inserted for the carotid procedures, whereas a 9-F, 90-cm sheath was chosen for the celiac aneurysm. Cerebral protection and stenting were successfully performed in all carotid patients; an 8x40-mm stent-graft was implanted to exclude the celiac artery aneurysm. An 8-F vascular closure device was used in the axillary arteries; hemostasis was immediate, and no hematoma or other complications were recorded in follow-up. CONCLUSIONS: This preliminary experience revisits the axillary approach as an alternative access route for interventional procedures. In association with a vascular closure device, this approach should be considered as a useful and safe option for those interventional procedures in which larger sheaths or catheters are required to cope with difficult arterial anatomies.

Aneurysm↗

Percutaneous treatment of carotid stenosis with protection system: preliminary experience.

PURPOSE: To assess the feasibility, safety, and efficacy of carotid artery stenting with filter device. MATERIALS AND METHODS: Between May 2001 and July 2002, a total of 96 consecutive patients (100 lesions) who presented with symptomatic >70% diameter stenosis, asymptomatic >90% diameter stenosis or post-endarterectomy as well as post-radiotherapy hemodynamically significant stenosis underwent carotid artery stenting with filter protection at our institute. The mean age of the patients was 72 (range 51-91). There were 22 female (23%), and 74 male (77%). Of the 96 patients, 62 patients (65%) did not filled the NASCET surgical criteria and 24 (26%) were classified as ASA 4. All the patients underwent pretreatment with antiplatelet agents. All procedures were performed with a standardized monitoring system by a multidisciplinary team. Filtration system for cerebral protection was consistently used. Outcome measures were procedural atheroembolic events, including all-stroke and death rates up to 30 days. RESULTS: A protection system type "TRAP" (Microvena, Italy) or a protection system type "EPIFILTER" (Boston Scientific, USA) were employed in 28% and 67% of cases, respectively. In the remaining 5% it was not possible to cross the stenosis with the filter. The stent placement was achieved in 95 of the procedures (95%). In 86% of cases a primary stenting technique was performed, with balloon pre-dilation of the lesion and subsequent stent advancement through the stenosis accounting for 9% of cases. At the time of protection system removal, 21 filter (21%) showed presence of macroscopic particles. We recorded 8 (8%) homolateral neurological events: two major strokes, one minor stroke and five TIAs (all the patients with TIA fully recovered within 2 hours). General complications (5%) included one lesion of the median nerve, two groin haematomas (one with disability for the patient, and one requiring surgery), one myocardial infarct and one lower limb ischaemia requiring surgical intervention. All major complications (4%) (two major strokes, one myocardial infarct and one lesion of the median nerve) occurred within the first 31 cases, the 69 following procedures not showing any neurological or non-neurological major events. At 30 days all patient were still alive. CONCLUSIONS: Filter protection during carotid artery stenting seems technically feasible as well as reasonably safe and effective. The EPIFILTER system turned out to be of easier employment due to its "monorail" system and because it does not usually need a catheter of dedicated recovery. Further studies in larger groups of patients are required to best characterize criteria guiding the choice for the right protection system.

Aged↗

Endovascular treatment of giant splenic aneurysm that developed after liver transplantation.

Splenic artery aneurysms (SAAs) are not uncommon in patients with portal hypertension. They are usually diagnosed in preliminary examinations prior to orthotopic liver transplantation (OLT) and are treated surgically at the time of transplantation. In our case, the patient developed a giant SAA after liver transplantation. This was detected incidentally upon routine ultrasound follow-up, and the diagnosis was confirmed on magnetic resonance (MR) angiography. The patient was treated by endovascular embolization because it is believed that this minimally invasive approach is beneficial in an immunocompromised patient following OLT. After coil embolization, to achieve complete and immediate blood flow exclusion of the sac, it was decided to inject some glue ( N-butyl-2-cyanoacrylate) directly into the aneurysm. The aneurysm was successfully obliterated. To the best of our knowledge the use of cyanoacrylate glue in an SSA has never been reported.

Aneurysm↗

Giant high-flow renal arteriovenous fistula treated by percutaneous embolization.

We report the case of a giant renal arteriovenous fistula after renal biopsy in a 30-year-old man with hematuria and hypertension. We performed percutaneous endovascular embolization using macrocoils to exclude the fistula. The patient made an uneventful recovery with no further hematuria and progressive reduction of blood pressure. Follow-up by digital subtraction angiography (DSA) at 6 months showed complete occlusion of the fistula with no evidence of renal parenchymal infarction. Although giant renal arteriovenous fistulas are generally treated by nephrectomy, this case shows that embolization is a reasonable alternative to surgery.

Adult↗

Embolization of a renal artery aneurysm using ethylene vinyl alcohol copolymer (Onyx).

PURPOSE: To report the embolization of a renal artery aneurysm using Onyx, a radiopaque nonadhesive liquid embolic agent. CASE REPORT: A 28-year-old woman with hypertension and fibromuscular dysplasia presented with a 20-mm renal artery aneurysm. In order to avoid any migration of embolic material into the parent vessel, a compliant balloon was inflated to exclude the aneurysm from the blood flow while injecting the liquid embolic agent. Complete aneurysm exclusion was achieved immediately, with no angiographic or duplex evidence of distal embolization or intra-aneurysmal flow. The Doppler ultrasound at 6 months confirmed aneurysm exclusion. CONCLUSIONS: The ease of use and nature of this material makes Onyx an effective and safe option in the treatment of wide-necked renal aneurysms.

Adult↗