PubMed Health⌕ Search

Biomedical subjects

Tomokazu Numano

Publications and source records attributed to Tomokazu Numano.

3 recordsLinked to original sources

In vivo isotropic 3D diffusion tensor mapping of the rat brain using diffusion-weighted 3D MP-RAGE MRI.

The purpose of this study was to examine the potential of diffusion-weighted (DW) three-dimensional (3D) MP-RAGE MRI for diffusion-tensor mapping of the rat brain in vivo. A DW-3D-MP-RAGE (3D-DWI) sequence was implemented at 2.0 T using six gradient orientations and a b value of 1000 s/mm2. In this sequence, the preparation sequence with a "90 degrees RF-motion proving gradient (MPG): MPG-180 degrees RF-MPG-90 degrees RF" pulse train (DW driven equilibrium Fourier transform) was used to sensitize the magnetization to diffusion. A centric k-space acquisition order was necessary to minimize saturation effects (T1 contamination) from tissues with short relaxation time. The image matrix was 128x128x128 (interpolated from 64x64x64 acquisitions), which resulted in small isotropic DW image data (voxel size: 0.273x0.273x0.273 mm3). Moreover, 3D-DWI-derived maps of the fractional anisotropy (FA), relative anisotropy (RA) and main-diffusion direction were completely free of susceptibility-induced signal losses and geometric distortions. Two well-known commissural fibers, the corpus callosum and anterior commissure, were indicated and shown to be in agreement with the locations of these known stereotaxic atlases. The experiment took 45 min, and shorter times should be possible in clinical application. The 3D-DWI sequence allows for in vivo 3D diffusion-tensor mapping of the rat brain without motion artifacts and susceptibility to distortion.

Animals↗

Assessment of fixed charge density in regenerated cartilage by Gd-DTPA-enhanced MRI.

PURPOSE: Applying regenerated cartilage in a clinical setting requires noninvasive evaluation to detect the maturity of cartilage tissue. Magnetic resonance (MR) imaging of articular cartilage is well accepted and has been applied clinically in recent years. We attempt to establish a noninvasive method to evaluate the maturity of regenerated cartilage tissue using gadolinium-enhanced MR imaging. METHODS: To reconstruct cartilaginous tissue, we embedded articular chondrocytes harvested from bovine humeral head in agarose gel and cultured the cells in vitro up to 4 weeks. The fixed charge density (FCD) of the cartilage was determined using MRI gadolinium exclusion method. The sulfated glycosaminoglycan (sGAG) content was determined by dimethylmethylene blue dye-binding assay. RESULTS: The sGAG content and FCD of the regenerated cartilage increased with duration of culture. In the T1Gd maps, the [Gd-DTPA(2-)] in the specimen decreased, and the boundary between the sample disk and the bath solution of phosphate buffered saline (PBS) became clearer as time in culture increased. In the linear regression analysis, FCD and sGAG content correlated significantly. CONCLUSION: Gadolinium-enhanced MR imaging measurements can be useful predictors of the degree of cartilaginous tissue formation.

Animals↗

Diffusion-weighted three-dimensional MP-RAGE MR imaging.

The advantages of three-dimensional (3D) acquisition are that you obtain thinner and more slices with better profiles, and better signal-to-noise ratio for an equivalent slice thickness. Three-dimensional acquisition is preferable for obtaining contiguous thin-slice MR images. However, the acquisition time extends compared with the two-dimensional acquisition because the second phase-encode axis is applied by the 3D acquisition. Therefore, 3D acquisition should be a high-speed imaging method. In this paper, a new diffusion-sensitive 3D magnetization-prepared rapid gradient-echo (3D MP-RAGE) sequence was studied. In this sequence, a preparation phase with a 90 degrees RF-motion proving gradient (MPG): MPG-180 degrees RF-MPG-90 degrees RF pulse train (diffusion-weighted driven-equilibrium Fourier transform) was used to sensitize the magnetization to diffusion. Centric k-space acquisition order is necessary to minimize saturation effects from tissues with short relaxation times. From phantom experimental results, the effect of the diffusion weighting was changed by the centric vs. sequential k-space acquisition order. The effect of centric k-space acquisition order was larger than the effect of sequential k-space acquisition order. The contrast of centric k-space acquisition order became equal to the contrast of conventional diffusion-weighted spin echo. From rat experimental results, small isotropic diffusion-weighted image data (voxel size: 0.625 x 0.625 x 0.625 mm3) were obtained. This sequence was useful in vivo.

Acetone↗