PubMed Health⌕ Search

Biomedical subjects

Tomoyuki Yamamoto

Publications and source records attributed to Tomoyuki Yamamoto.

5 recordsLinked to original sources

First-principles calculations of migration energy of lithium ions in halides and chalcogenides.

Migration of Li+ ions via the vacancy mechanism in LiX (X = F, Cl, Br, and I) with the rocksalt and hypothetical zinc blende structures and Li2X (X = O, S, Se, and Te) with the antifluorite structure has been investigated using first-principles projector augmented wave calculations with the generalized gradient approximation. The migration paths and energies, determined by the nudged-elastic-band method, are discussed on the basis of two idealized models: the rigid-sphere and charged-sphere models. The trajectories and energy profiles of the migration in these lithium compounds vary between these two models, depending on the anion species and crystal structure. The migration energies in LiX with both the rocksalt and hypothetical zinc blende structures show a tendency to decrease with increasing periodic number of the anion species in the periodic table. This is consistent with the widely accepted view that anion species with large ionic radii and high polarizabilities are favorable for good ionic conduction. In contrast, Li2O exhibits the lowest migration energy among Li2X compounds, although O is the smallest among the chalcogens, indicating that electrostatic attractive interactions play the dominant role in the inter-ion interactions in Li2O and, therefore, in the ion migration.

Journal Article↗

Development of a method for reconstructing three-dimensional data from axial, sagittal, and coronal MR images.

Magnetic resonance (MR) imaging is useful for the diagnosis of brain atrophy and intracranial abnormalities. We have developed a method of automated volumetry to evaluate the degree of brain atrophy for the diagnosis of dementia. Whole-brain MR images with thin slices without gaps are required for segmentation and volumetry. However, obtaining such images requires that the patient remain at rest for a prolonged period, thereby reducing the throughput of MR imaging examinations. Therefore, a method is needed for the reconstruction of isotropic three-dimensional (3D) data using routine axial, sagittal, and coronal MR images with 30% gaps and measurement of brain volume. The method of reconstructing 3D data consists of four processes: 1) segmentation of the brain region on axial, sagittal, and coronal MR images using the region-growing technique; 2) setting data to a 3D domain; 3) registration by manual operation; and 4) interpolation between the data based on linear interpolation. In clinical MR images, the differences between this method and the conventional technique were less than 10%. These results demonstrate that this technique is able to construct 3D data from axial, sagittal, and coronal MR images.

Adult↗

[Measurement of patient skin dose in interventional radiology using passive integrating dosimeter].

To avoid radiation injury from interventional radiology (IVR), quality assurance (QA) of IVR equipment based on dosimetry is important. In this study, we investigated the usefulness of measuring patient skin dose with a passive integrating dosimeter and water phantom. The optically stimulated luminescence dosimeter (OSLD) was chosen from among various passive integrating dosimeters. The characteristics of the OSLD were compared with a reference ionization dosimeter. The effective energy obtained from the OSLD was compared with that found by the aluminum attenuation method for using the reference ionization dosimeter. Doses and effective energies measured by OSLD correlated well with those of the reference ionization dosimeter. (dose: y=0.971x, r=0.999, effective energy: y=0.990x, r=0.994). It was suggested that OSLD could simultaneously and correctly measure both patient skin dose and effective energy. Patient skin dose rate and effective energy for 15 IVR units of 10 hospitals were investigated using OSLD and a water phantom for automatic brightness control fluoroscopy. The measurement was performed at the surface of a water phantom that was located on the interventional reference point, and source image intensifier distance was fixed to 100 cm. When the 9-inch field size was selected, the average patient skin dose rate was 16.3+/-8.1 mGy/min (3.6-32.0 mGy/min), the average effective energy was 34.6+/-4.1 keV (30.5-42.5 keV). As a result, it was suggested that QA should be performed not only for patient dose but also for effective energy. QA of equipment is integral to maintaining consistently appropriate doses. Consequently, the dosimetry of each IVR unit should be regularly executed to estimate the outline of patient skin dose. It was useful to investigate patient skin dose/effective energy with the passive integrating dosimeter for IVR equipment.

Humans↗

Evaluation of variations in absorbed dose and image noise according to patient forms in X-ray computed tomography.

Excessive radiation exposure in pediatric computed tomography (CT) scanning has become a serious problem, and it is difficult to select scan parameters for the scanning of small patients such as children. We investigated differences in absorbed dose and standard deviation (SD) in Hounsfield unit (HU) caused by differences in the form of the subject using a body-type phantom with removable body parts. Using four X-ray CT scanners, measurements were made with values from 50 mAs to 300 mAs, with slices of 50 mAs, using scan protocols that were assumed to perform thorough examinations. The results showed that the mAs values and absorbed doses were almost proportional, and the absorbed doses in the phantom without body parts were about 1.1-2.2-fold higher than those of the phantom with body parts at the same points. The SD values obtained indicated that the absorbed doses in the phantom with body parts were 0.3-0.6 times those of the phantom without body parts when the mAs values used were adjusted so that both SD values were the same. The absorbed doses in various patient forms can be estimated from these results, and they will become critical data for the selection of appropriate scan protocols.

Dose-Response Relationship, Radiation↗

Identification of ultradilute dopants in ceramics.

The properties of ceramic materials are strongly influenced by the presence of ultradilute impurities (dopants). Near-edge X-ray absorption fine structure (NEXAFS) measurements using third-generation synchotron sources can be used to identify ultradilute dopants, provided that a good theoretical tool is available to interpret the spectra. Here, we use NEXAFS analysis and first-principles calculations to study the local environments of Ga dopants at levels of 10 p.p.m in otherwise high-purity MgO. This analysis suggests that the extra charge associated with substitutional Ga on a Mg site is compensated by the formation of a Mg vacancy. This defect model is then confirmed by positron lifetime measurements and plane-wave pseudopotential calculations. This powerful combination of techniques should provide a general method of identifying the defect states of ultradilute dopants in ceramics.

Ceramics↗