PubMed Health⌕ Search

Biomedical subjects

Tongtong Liu

Publications and source records attributed to Tongtong Liu.

3 recordsLinked to original sources

Development of a high-throughput in vitro assay using a novel Caco-2/rat hepatocyte system for the prediction of oral plasma area under the concentration versus time curve (AUC) in rats.

INTRODUCTION: Previously, we have shown that a novel Caco-2/human hepatocyte system is a useful model for the prediction of oral bioavailability in humans. In this study, we attempted to use a similar system in a high-throughput screening mode for the selection of new compound entities (NCE) in drug discovery. METHODS: A total of 72 compounds randomly selected from three different chemotypes were dosed orally in rats. In vivo plasma area under the concentration versus time curve (AUC) from 0-6 h of the parent compound was determined. The same compounds were also tested in the Caco-2/rat hepatocyte system. In vitro AUC from 0-3 h in the Caco-2 rat hepatocyte system was determined. RESULTS: The predictive usefulness of the Caco-2/rat hepatocyte system was evaluated by comparing the in vivo plasma AUC and the in vitro AUC. Linear regression analysis showed a reasonable correlation (R2 = 0.5) between the in vivo AUC and the in vitro AUC. Using 0.4 microM h in vivo AUC as a cut-off, compounds were categorized as either low or high AUC. The in vitro AUC successfully matched the corresponding in vivo category for sixty-three out of seventy-two compounds. DISCUSSION: The results presented in this study suggest that the Caco-2/rat hepatocyte system may be used as a high-throughput screen in drug discovery for pharmacokinetic behaviors of compounds in rats.

Administration, Oral↗

A fully automated nanoelectrospray tandem mass spectrometric method for analysis of Caco-2 samples.

Caco-2 cells offer a means to rapidly screen permeability of drug candidates, allowing pharmaceutical companies to eliminate candidates unable to cross the intestinal barrier early in the discovery process. This screening process is typically performed by conventional liquid chromatography/tandem mass spectrometry (LC/MS/MS), which can require time-consuming method development. An alternative to LC/MS/MS, automated nanoelectrospray tandem mass spectrometry (nanoESI-MS/MS), is introduced. This novel approach requires an off-line ZipTip desalting step followed by automated nanoESI-MS/MS, using the NanoMate 100 and ESI Chip. In addition to reduced method development time, automated nanoESI-MS/MS also offers no carry-over between samples, low sample consumption, and ease-of-use as compared with conventional pulled-capillary nanoelectrospray. Furthermore, the infusion system described has the potential to be high-throughput. A comparison of Caco-2 samples analyzed both by LC/MS/MS and by automated nanoESI-MS/MS is presented. The permeability and recovery data of the two compounds analyzed in this study obtained from conventional LC/MS/MS and by automated nanoESI-MS/MS were in excellent agreement.

Algorithms↗

Higher-throughput screening for Caco-2 permeability utilizing a multiple sprayer liquid chromatography/tandem mass spectrometry system.

In the current drug discovery environment, higher-throughput analytical assays have become essential to keep pace with the screening demands for drug metabolism and pharmacokinetics (DMPK) attributes. This has been dictated by advances primarily in chemical procedures, notably combinatorial and parallel syntheses, which has resulted in many-fold increases in the number of compounds requiring DMPK evaluation. Because of its speed and specificity, liquid chromatography/tandem mass spectrometry (LC/MS/MS) has become the dominant technology for sample analysis in the DMPK screening assays. For higher-throughput assays, analytical speed as well as other factors such as method development, data processing, quality control, and report generation, must be optimized. The four-way multiplexed electrospray interface (MUX), which allows for the analysis of four LC eluents simultaneously, has been adopted to maximize the rate of sample introduction into the mass spectrometer. Generic fast-gradient HPLC methods that are suitable for approximately 80% of the new chemical entities encountered have been developed. In-house-written software programs have been used to streamline information flow within the system, and for quality control by automatically identifying analytical anomalies. By integrating these components together with automated method development and data processing, a system capable of screening 100 compounds per week for Caco-2 permeability has been established.

Absorption↗