PubMed Health⌕ Search

Biomedical subjects

Toni S Roddey

Publications and source records attributed to Toni S Roddey.

12 recordsLinked to original sources

Shoulder dysfunction assessment: self-report and impaired scapular movements.

BACKGROUND AND PURPOSE: Shoulder dysfunction is common in various patient populations. This investigation was performed to assess shoulder dysfunction with self-report and performance-based functional measures. SUBJECTS: Fifty men (25 with shoulder dysfunction and 25 without shoulder dysfunction) participated in this study. METHODS: Self-report functional disabilities were assessed with the Flexilevel Scale of Shoulder Function (FLEX-SF), and electromagnetic tracking sensors were used to monitor 3-dimensional scapular movements during 4 functional tasks. RESULTS: Relative to the control group, the group with shoulder dysfunction showed significant alterations in scapular movements (averages of 6.9 degrees less posterior tipping, 5.7 degrees less upward rotation, and 2.3 cm more elevation). Scapular kinematics correlated significantly (r) with the Self-report FLEX-SF measure during functional tasks (posterior tipping = .454 to .712, upward rotation = .296 and .317, and elevation = -.310). DISCUSSION AND CONCLUSION: Functional disabilities were identified with self-report and performance-based functional measures. The inadequate scapular posterior tipping and scapular upward rotation as well as the excessive elevation may have implications in planning intervention strategies for people with shoulder dysfunction.

Activities of Daily Living↗

Altered patterns of muscle activation during performance of four functional tasks in patients with shoulder disorders: interpretation from voluntary response index.

Altered motor control of the shoulder muscles during performance of a specific motor task in patients with shoulder disorders (SDs) has been an interesting subject to researchers. This study compared shoulder muscle activation patterns by surface electromyography (sEMG), including the upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA) muscles, during four functional tasks in 25 patients with SDs and controls. A voluntary response index (VRI) was calculated, including magnitude and similarity index (SI), to quantify sEMG patterns during four functional tasks. Responsiveness and clinically meaningful levels of discrimination between patients and control for EMG magnitude and SI were determined. An altered pattern of motor control during four functional tasks was evident in the patients, in which greater EMG amplitude and abnormal EMG patterns were found. For SI among four functional tasks, normal subjects ranged from 0.80 to 1.00 while patients ranged from 0.70 to 0.99. High probabilities (97%) of discrimination between patients and normal subjects were found by SI method during an overhead height task (patients: 0.85-0.96, normal subjects: 0.95-1.00). Our results also suggest that an individual can be estimated to be abnormal when lower SI values are observed during the four functional tasks.

Adaptation, Physiological↗

Functional activity characteristics of individuals with shoulder dysfunctions.

Shoulder-related dysfunction affects individuals' ability to function independently and thus decreases quality of life. Functional task assessment is a key concern for a clinician in diagnostic assessment, outcome measurement, and planning of treatment programs. The purpose of this study was to test the reliability of the FASTRAK 3-dimensional (3-D) motion analysis and surface electromyography (sEMG) systems to analyze 3-D shoulder complex movements during functional tasks and compare motion patterns between subjects with and without shoulder dysfunctions (SDs).For the test, sEMG and 3-D motion analysis systems were used to characterize the functional tasks. Twenty-five asymptomatic male subjects and 21 male subjects with right shoulder disorders performed four functional tasks which involved arm reaching and raising activities with their dominant arms. Reliability was estimated by the intraclass correlation coefficient (ICC). Motion pattern was compared between two groups using mixed analysis of variances (ANOVAs). Shoulder complex kinematics and associated muscular activities during functional tasks were reliably quantified (ICC=0.83-0.99) from the means of three trials. Relative to the group without SDs, the group with SDs showed significant alteration in shoulder complex kinematics (3 degrees -40 degrees ) and associated muscular activities (3-10% maximum). Scapular tipping, scapular elevation, upper trapezius muscle function, and serratus anterior muscle function may have implications in the rehabilitation of patients with SDs.

Adult↗

Dynamic assessment of health outcomes: time to let the CAT out of the bag?

BACKGROUND: The use of item response theory (IRT) to measure self-reported outcomes has burgeoned in recent years. Perhaps the most important application of IRT is computer-adaptive testing (CAT), a measurement approach in which the selection of items is tailored for each respondent. OBJECTIVE: To provide an introduction to the use of CAT in the measurement of health outcomes, describe several IRT models that can be used as the basis of CAT, and discuss practical issues associated with the use of adaptive scaling in research settings. PRINCIPAL POINTS: The development of a CAT requires several steps that are not required in the development of a traditional measure including identification of "starting" and "stopping" rules. CAT's most attractive advantage is its efficiency. Greater measurement precision can be achieved with fewer items. Disadvantages of CAT include the high cost and level of technical expertise required to develop a CAT. CONCLUSIONS: Researchers, clinicians, and patients benefit from the availability of psychometrically rigorous measures that are not burdensome. CAT outcome measures hold substantial promise in this regard, but their development is not without challenges.

Health Services Research↗

Reliability of selected physical performance tests in young adult women.

The purposes of this investigation were to establish the reliability of selected physical performance tests in women athletes and nonathletes and to determine performance differences between groups. Fifty women (25 athletes, 25 nonathletes) performed 5 tests in 2 sessions. The performance tests included the figure-eight hop test, up-and-down hop test, side-to-side hop test, hexagon hop test, and zigzag run test. Intraclass correlation coefficients (ICC [2, 1]) were calculated for trial-to-trial, intertester, and day-to-day reliability. Independent t-tests with Bonferroni adjustment (alpha = 0.01) were used for each individual test to compare differences between groups. All tests showed good reliability values (ICC > or = 0.76) in the nonathlete group for all conditions and varied reliability values (0.48-0.99) among conditions in the athlete group. The independent t-tests showed a statistically significant group effect (t > or = 3.041; p < or = 0.004) for all tests. The results showed that these physical performance tests are reliable measurement tools in the female population.

Adult↗

Outcome expectancies, functional outcomes, and expectancy fulfillment for patients with shoulder problems.

OBJECTIVES: This study was conducted to evaluate the relationship among patient outcome expectancies, perceived shoulder function changes, and perceptions of expectancy fulfillment. METHODS: Patients (n = 199) treated for shoulder problems at one orthopedic surgeon's office completed a baseline survey comprised of measures of outcome expectancies, shoulder function, health status, and demographics. At 1 month, 2 months, and 3 months, patients completed a mailed follow-up survey comprised of all baseline measures except demographic variables. At 3 months, a measure of expectancy fulfillment was added. A general linear modeling approach was used to assess the significance and effect size of 1) outcome expectancies on changes in shoulder function; and (2) outcome expectancies, shoulder function changes, and their interaction on perceptions of expectancy fulfillment. RESULTS: Outcome expectancies significantly predicted changes in shoulder function and accounted for 10% of the variance in functional improvement. The improvement difference between patients with high expectancies compared with those with low expectancies was clinically relevant (4.57 points), as it was greater than the minimal clinically important difference (3.02 points). Outcome expectancies and shoulder function changes significantly predicted patients' perceptions of fulfilled expectancies, but their interaction was not statistically significant. CONCLUSIONS: Results highlight the importance of patient expectancy in medical encounters. The findings suggest the need for interventions targeting patient expectancies such as including discussions about expectancy in patient-physician negotiations of therapeutic plans. Results also underscore the need for the development of better measures of outcome expectancies and expectancy fulfillment.

Adolescent↗

Development and psychometric evaluation of the Flexilevel Scale of Shoulder Function.

BACKGROUND: Existing measures of self-reported shoulder function fail to measure effectively the full range of shoulder functioning. The classic approach for improving the reliability of a scale is adding items, but a scale with a substantial number of items imposes a large response burden on participants. A more efficient approach is to use modern psychometric methods to construct an adaptive scale in which patients respond only to items that are targeted at their level of shoulder function. METHODS: We developed a Flexilevel Scale of Shoulder Function (FLEX-SF). This scale includes three testlets that target low, medium, and high shoulder function. Scores on the testlets were equated to a common mathematical metric. DESIGN AND SUBJECTS: We developed an initial pool of 68 items. This pool was administered to 400 patients, and responses were calibrated using a rating scale model. Subsets of items were identified for an easy, medium difficulty, and hard testlet. Properties of the scale were evaluated in a 3-month longitudinal study of 200 shoulder patients. RESULTS: The FLEX-SF exhibited high reliability at both the scale level (intraclass correlation coefficient [3,1] = 0.90) and specific trait levels. The validity of the FLEX-SF was supported by its internal and external responsiveness (Guyatt responsiveness index = 1.12) and the pattern of its associations with other health status measures. CONCLUSIONS: The FLEX-SF can be used as a primary endpoint in clinical trials even when there are relatively few people in each treatment group. The scale also has excellent properties for use in clinical settings tracking individual changes over time.

Adult↗

A randomized controlled trial comparing 2 instructional approaches to home exercise instruction following arthroscopic full-thickness rotator cuff repair surgery.

STUDY DESIGN: A prospective unblinded randomized clinical trial. OBJECTIVES: To compare the effectiveness of 2 types of home program instruction, videotape versus personal instruction by a physical therapist, on subjective outcomes and exercise compliance following arthroscopic repair of a full-thickness rotator cuff tear. BACKGROUND: Advances in orthopedic surgery and rehabilitation have placed increased emphasis on home exercise programs. Therefore, assessing the effectiveness of different methods of home program instruction is important. METHODS AND MEASURES: Patients who consented to undergo surgical repair were randomly assigned to either a videotape or personal instruction group. A self-reported compliance log categorized subjects as fully compliant, partially compliant, or noncompliant. The Shoulder Pain and Disability Index and the University of Pennsylvania Shoulder Scale scores were obtained from subjects preoperatively and at 12, 24, and 52 weeks postoperatively. The null hypotheses that neither group would have better outcomes as measured by 2 shoulder outcome scales at any level of compliance over 4 levels of time, were assessed by 2 separate 2x3x4 multiple analyses of variances (MANOVAs), 1 for each outcome measure (alpha = 0.025). RESULTS: Neither MANOVA was significant and the null hypotheses were not rejected. The main effect of time (number of weeks postsurgery) was significant across all time intervals for both outcome measures (P < 0.0005). CONCLUSIONS: With a therapist available for questions, patients who utilized the videotape method for their home program instruction had self-reported outcomes equal to patients instructed in their home program personally by a physical therapist. Self-reported compliance with the rehabilitation program had little effect on the outcomes.

Adult↗

Reliability by surgical status of self-reported outcomes in patients who have shoulder pathologies.

STUDY DESIGN: A test-retest design was used to evaluate the reliability of the self-report sections of 4 shoulder pain and disability scales. OBJECTIVE: The objective of the study was to compare interitem consistency and test-retest reliability by surgical status (postoperative versus nonoperative) and to evaluate the effect of surgical status in the prediction of retest scores. BACKGROUND: Patients and healthcare providers evaluate shoulder status based on self-evaluations of pain and disability. Shoulder outcome measures have been developed that include self-reports, but the properties of these measures have not been assessed by surgical status. METHODS AND MEASURES: A questionnaire containing self-report sections of 4 shoulder scales was administered to study participants twice with 1 week between administrations. The outcome measures examined were the: (1) University of California at Los Angeles (UCLA) Shoulder Score; (2) Constant-Murley Scale (CMS); (3) American Shoulder and Elbow Society (ASES) Shoulder Index; and (4) Shoulder Pain and Disability Index (SPADI). Intraclass correlation coefficients (ICC) were calculated to estimate the test-retest reliability of each of the scales and subscales. The interitem consistencies of the multi-item subscales were assessed using Cronbach's alpha. The effect of surgical status on shoulder outcome scale reliability was evaluated using a general linear models approach. RESULTS: The interitem consistency estimates for the multi-item scales were high with both operative and nonoperative participants (0.88 to 0.96). With the exception of the satisfaction subscale of the UCLA Shoulder Score for the nonsurgical group, the estimated intraclass coefficients ranged from 0.51 to 0.91. The prediction of UCLA-satisfaction and ASES-disability, pain, and total retest scores was improved with the addition of surgical status into a regression model. CONCLUSIONS: The examined scales exhibited good internal consistency across surgical status. The postsurgical sample's reproducibility estimates tended to be higher than those of the nonsurgical sample. Reliability of shoulder outcome scales can be affected by patient surgical status.

Adult↗

The relationship among strength and mobility measures and self-report outcome scores in persons after rotator cuff repair surgery: impairment measures are not enough.

In the past, measures of active range of motion and strength testing were deemed sufficient to "prove" the efficacy of treatment interventions. In the current outcomes milieu, however, the focus has shifted to patient-centered assessment (ie, patients' ability to perform activities that are personally relevant). We report results from a study with patients in the private practice of a shoulder surgeon. In this study we evaluated the relationship between impairment measures and scores from several shoulder outcome scales. In addition, we examined transcripts of interviews with shoulder patients regarding the impact of shoulder problems on their lives. One hundred eight persons participated in a randomized trial of home exercise instruction after arthroscopic repair of rotator cuff tears. Two impairment measures were used-strength estimates obtained by use of a Nicholas electronic dynamometer and range of motion in the standing position. Self- reported outcomes were measured by use of the Shoulder Pain and Disability Index (SPADI) and the University of Pennsylvania (UPenn) Shoulder Scale. Pearson correlation coefficients were calculated to estimate the associations between scores on impairment measures and self-report measures. R 2 values were calculated to estimate the proportion of variance shared by impairment and self-report scores. We found that the linear relationship between impairment scores and patient-reported outcomes was quite low, explaining as little as 8% of the total variance. Qualitative analysis of patient interviews suggests that patients distinguish between their impairment and their status on personally relevant outcomes. Future research should evaluate the nature of patient judgments of shoulder health outcomes.

Exercise Therapy↗

Development of a Flexilevel Scale for use with computer-adaptive testing for assessing shoulder function.

In a 5-year study, a self-report measure of shoulder function-the Flexilevel Scale of Shoulder Function (FLEX-SF)-was developed by use of item response theory. A large pool of candidate items (N = 68) was developed. A questionnaire that included the 68 items, another scale of shoulder function, and clinical and demographic questions were administered to 400 persons with shoulder complaints. Patients' responses to the 68 items were calibrated by use of Andrich's rating scale model. Thirty-three items were selected from the pool and subdivided into three overlapping testlets targeting low, medium, and high shoulder function. A table translates raw scores on testlets to a common mathematical metric. The validity and reliability of the FLEX-SF was evaluated in a longitudinal study of 199 patients. The FLEX-SF scores were highly reliable and exhibited excellent validity (including responsiveness). We report on a simulation of a computer-adaptive test of shoulder function. This simulation is based on the developmental items we tested for use in the FLEX-SF. The results indicate that greater measurement efficiency can be achieved with a computer-adaptive test format.

Computer Simulation↗

Functional activities characteristics of shoulder complex movements: Exploration with a 3-D electromagnetic measurement system.

The high prevalence of shoulder-related dysfunction has focused increased attention on functional activity assessment. This study (1) tested the reliability of three-dimensional shoulder complex movements during four functional tasks representing different levels of task difficulty, (2) characterized the four functional tasks, and (3) examined the relationships between age and shoulder movements. Twenty-five asymptomatic subjects, all veterans aged 30-82, performed the four functional tasks. Good within-session reliability was found (movement pattern: similarity index = 0.81 to 0.97, peak values: intraclass correlation coefficients = 0.88 to 0.99). The raising arm to overhead height task (hard task) placed the greatest demand on scapular motions and humeral elevation (p < 0.005). During the functional tasks, significant correlations existed between age and scapular tipping, humeral elevation, and scapular upward rotation (r = -0.62 to 0.50, p < 0.05). Correlation results indicated that elderly subjects have a greater potential for serratus anterior muscle weakness and shoulder capsule tightness.

Adult↗