Effects of teriparatide and alendronate on vertebral strength as assessed by finite element modeling of QCT scans in women with osteoporosis.

UNLABELLED: FE modeling was used to estimate the biomechanical effects of teriparatide and alendronate on lumbar vertebrae. Both treatments enhanced predicted vertebral strength by increasing average density. This effect was more pronounced for teriparatide, which further increased predicted vertebral strength by altering the distribution of density within the vertebra, preferentially increasing the strength of the trabecular compartment. INTRODUCTION: Teriparatide 20 microg/day (TPTD) and alendronate 10 mg/day (ALN) increase areal, measured by DXA, and volumetric, measured by QCT, lumbar spine BMD through opposite effects on bone remodeling. Using finite element (FE) modeling of QCT scans, we sought to compare the vertebral strength characteristics in TPTD- and ALN-treated patients. MATERIALS AND METHODS: A subset of patients (N = 28 TPTD; N = 25 ALN) from the Forteo Alendronate Comparator Trial who had QCT scans of the spine at baseline and postbaseline were analyzed. The QCT scans were analyzed for compressive strength of the L(3) vertebra using FE modeling. In addition, using controlled parameter studies of the FE models, the effects of changes in density, density distribution, and geometry on strength were calculated, a strength:density ratio was determined, and a response to bending was also quantified. RESULTS: Both treatments had positive effects on predicted vertebral strength characteristics. At least 75% of the patients in each treatment group had increased strength of the vertebra at 6 months compared with baseline. Patients in both treatment groups had increased average volumetric density and increased strength in the trabecular bone, but the median percentage increases for these parameters were 5- to 12-fold greater for TPTD. Larger increases in the strength:density ratio were also observed for TPTD, and these were primarily attributed to preferential increases in trabecular strength. CONCLUSIONS: These results provide new insight into the effects of these treatments on estimated biomechanical properties of the vertebra. Both treatments positively affected predicted vertebral strength through their effects on average BMD, but the magnitudes of the effects were quite different. Teriparatide also affected vertebral strength by altering the distribution of density within the vertebra, so that overall, teriparatide had a 5-fold greater percentage increase in the strength:density ratio.

Aged↗

Adaptation of cellular mechanical behavior to mechanical loading for osteoblastic cells.

Numerous cellular biochemical responses to mechanical loading are transient, indicating a cell's ability to adapt its behavior to a new mechanical environment. Since load-induced cellular deformation can initiate these biochemical responses, the overall goal of this study was to investigate the adaptation of global, or whole-cell, mechanical behavior, i.e., cellular deformability, in response to mechanical loading for osteoblastic cells. Confluent cell cultures were subjected to 1 or 2 Pa flow-induced shear stress for 2 h. Whole-cell mechanical behavior was then measured for individual cells using an atomic force microscope. Compared to cells maintained under static conditions, whole-cell stiffness was 1.36-fold (p=0.006) and 1.70-fold (p<0.001) greater for cells exposed to 1 and 2 Pa shear loading, respectively. The increase in shear stress magnitude from 1 to 2 Pa also caused a statistically significant, 1.25-fold increase in cell stiffness (p=0.02). Increases in cell stiffness were not altered in either flow group for 70 min after flow was terminated (p=0.15). Flow-induced rearrangement of the actin cytoskeleton was also maintained for at least 90 min after flow was terminated. Taken together, these findings support the hypothesis that cells become mechanically adapted to their mechanical environment via cytoskeletal modifications. Accordingly, cellular mechanical adaptation may play a key role in regulation of cellular mechanosensitivity and the related effects on tissue structure and function.

3T3 Cells↗

Influence of bone volume fraction and architecture on computed large-deformation failure mechanisms in human trabecular bone.

Large-deformation bending and buckling have long been proposed as failure mechanisms by which the strength of trabecular bone can be affected disproportionately to changes in bone density, and thus may represent an important aspect of bone quality. We sought here to quantify the contribution of large-deformation failure mechanisms on strength, to determine the dependence of these effects on bone volume fraction and architecture, and to confirm that the inclusion of large-deformation effects in high-resolution finite element models improves predictions of strength versus experiment. Micro-CT-based finite element models having uniform hard tissue material properties were created from 54 cores of human trabecular bone taken from four anatomic sites (age = 70+/-11; 24 male, 27 female donors), which were subsequently biomechanically tested to failure. Strength predictions were made from the models first including, then excluding, large-deformation failure mechanisms, both for compressive and tensile load cases. As expected, strength predictions versus experimental data for the large-deformation finite element models were significantly improved (p < 0.001) relative to the small deformation models in both tension and compression. Below a volume fraction of about 0.20, large-deformation failure mechanisms decreased trabecular strength from 5-80% for compressive loading, while effects were negligible above this volume fraction. Step-wise nonlinear multiple regression revealed that structure model index (SMI) and volume fraction (BV/TV) were significant predictors of these reductions in strength (R2 = 0.83, p < 0.03). Even so, some low-density specimens having nearly identical volume fraction and SMI exhibited up to fivefold differences in strength reduction. We conclude that within very low-density bone, the potentially important biomechanical effect of large-deformation failure mechanisms on trabecular bone strength is highly heterogeneous and is not well explained by standard architectural metrics.

Biomechanical Phenomena↗

The effects of side-artifacts on the elastic modulus of trabecular bone.

Determining accurate density-mechanical property relationships for trabecular bone is critical for correct characterization of this important structure-function relation. When testing any excised specimen of trabecular bone, an unavoidable experimental artifact originates from the sides of the specimen where peripheral trabeculae lose their vertical load-bearing capacity due to interruption of connectivity, a phenomenon denoted here as the 'side-artifact'. We sought in this study to quantify the magnitude of such side-artifact errors in modulus measurement and to do so as a function of the trabecular architecture and specimen size. Using parametric computational analysis of high-resolution micro-CT-based finite-element models of cores of elderly human vertebral trabecular bone, a specimen-specific correction factor for the side-artifact was quantified as the ratio of the side-artifact-free apparent modulus (Etrue) to the apparent modulus that would be measured in a typical experiment (Emeasured). We found that the width over which the peripheral trabeculae were mostly unloaded was between 0.19 and 0.58 mm. The side-artifact led to an underestimation error in Etrue of over 50% in some specimens, having a mean (+/-SD) of 27+/-11%. There was a trend for the correction factor to linearly increase as volume fraction decreased (p=0.001) and as mean trabecular separation increased (p<0.001). Further analysis indicated that the error increased substantially as specimen size decreased. Two methods used for correcting for the side-artifact were both successful in bringing Emeasured into statistical agreement with Etrue. These findings have important implications for the interpretation of almost all literature data on trabecular bone mechanical properties since they indicate that such properties need to be adjusted to eliminate the substantial effects of side-artifacts in order to provide more accurate estimates of in situ behavior.

Aged↗

Effects of in vitro bone formation on the mechanical properties of a trabeculated hydroxyapatite bone substitute.

This study was designed to test the hypothesis that the mechanical properties of a trabecular bone substitute can be enhanced through in vitro tissue formation. Our specific objectives were to (1) determine the effects of in vitro marrow stromal cell-mediated tissue deposition upon a trabeculated hydroxyapatite scaffold on the strength and toughness of the resulting bone substitute; and (2) identify and characterize regions of newly deposited matrix and mineral. This work provides a basis for future investigations aimed at transforming a brittle hydroxyapatite scaffold into an osteoinductive, biomechanically functional implant through in vitro bone deposition. As hypothesized, the mechanical properties of the trabecular bone substitutes were significantly enhanced by in vitro tissue formation. As a result of cell seeding and a 5 week culture protocol, mean strength increased by 85% (p = 0.008) and energy to fracture increased by 130% (p = 0.003). Accompanying the enhancement of mechanical properties was the deposition of significant amounts of bone matrix and mineral. Fluorescence imaging, scanning electron microscopy, electron probe microanalysis, and nanoindentation confirmed the presence of bonelike mineral with Ca/P ratio, modulus, and hardness similar to that within human and rat trabecular bone tissue. This new mineralization was found to exist within a newly deposited parallel-fibered matrix both encasing and bridging between scaffold trabeculae. Taken as a whole, our results establish the feasibility of the production of an osteoinductive hydroxyapatite-based trabecular bone substitute with mechanical properties enhanced through in vitro bone deposition.

Animals↗

The effects of morphology, confluency, and phenotype on whole-cell mechanical behavior.

Emerging evidence indicates that cellular mechanical behavior can be altered by disease, drug treatment, and mechanical loading. To effectively investigate how disease and mechanical or biochemical treatments influence cellular mechanical behavior, it is imperative to determine the source of large inter-cell differences in whole-cell mechanical behavior within a single cell line. In this study, we used the atomic force microscope to investigate the effects of cell morphological parameters and confluency on whole-cell mechanical behavior for osteoblastic and fibroblastic cells. For nonconfluent cells, projected nucleus area, cell area, and cell aspect ratio were not correlated with mechanical behavior (p>or=0.46), as characterized by a parallel-spring recruitment model. However, measured force-deformation responses were statistically different between osteoblastic and fibroblastic cells (p<0.001) and between confluent and nonconfluent cells (p<0.001). Osteoblastic cells were 2.3-2.8 times stiffer than fibroblastic cells, and confluent cells were 1.5-1.8 times stiffer than nonconfluent cells. The results indicate that structural differences related to phenotype and confluency affect whole-cell mechanical behavior, while structural differences related to global morphology do not. This suggests that cytoskeleton structural parameters, such as filament density, filament crosslinking, and cell-cell and cell-matrix attachments, dominate inter-cell variability in whole-cell mechanical behavior.

Animals↗

Measurement and characterization of whole-cell mechanical behavior.

An understanding of whole-cell mechanical behavior can provide insight into cellular responses to mechanical loading and diseases in which such responses are altered. However, this aspect of cellular mechanical behavior has received limited attention. In this study, we used the atomic force microscope (AFM) in conjunction with several mechanical characterization methods (Hertz contact theory, an exponential equation, and a parallel-spring recruitment model) to establish a mechanically rigorous method for measuring and characterizing whole-cell mechanical behavior in the deformation range 0-500 nm. Using MC3T3-E1 osteoblasts, measurement repeatability was assessed by performing multiple loading cycles on individual cells. Despite variability in measurements, repeatability of the measurement technique was statistically confirmed. The measurement technique also proved acceptable since only 5% of the total variance across all measurements was due to variations within measurements for a single cell. The parallel-spring recruitment model, a single-parameter model, accurately described the measured nonlinear force-deformation response (R2>0.99) while providing a mechanistic explanation of whole-cell mechanical behavior. Taken together, the results should improve the capabilities of the AFM to probe whole-cell mechanical behavior. In addition, the success of the parallel-spring recruitment model provides insight into the micromechanical basis of whole-cell behavior.

Animals↗

Sensitivity of vertebral compressive strength to endplate loading distribution.

The sensitivity of vertebral body strength to the distribution of axial forces along the endplate has not been comprehensively evaluated. Using quantitative computed tomography-based finite element models of 13 vertebral bodies, an optimization analysis was performed to determine the endplate force distributions that minimized (lower bound) and maximized (upper bound) vertebral strength for a given set of externally applied axial compressive loads. Vertebral strength was also evaluated for three generic boundary conditions: uniform displacement, uniform force, and a nonuniform force distribution in which the interior of the endplate was loaded with a force that was 1.5 times greater than the periphery. Our results showed that the relative difference between the upper and lower bounds on vertebral strength was 14.2 +/- 7.0% (mean +/- SD). While there was a weak trend for the magnitude of the strength bounds to be inversely proportional to bone mineral density (R2 = 0.32, p = 0.02), both upper and lower bound vertebral strength measures were well predicted by the strength response under uniform displacement loading conditions (R2 = 0.91 and R2 = 0.99, respectively). All three generic boundary conditions resulted in vertebral strength values that were statistically indistinguishable from the loading condition that resulted in an upper bound on strength. The results of this study indicate that the uncertainty in strength arising from the unknown condition of the disc is dependent on the condition of the bone (whether it is osteoporotic or normal). Although bone mineral density is not a good predictor of strength sensitivity, vertebral strength under generic boundary conditions, i.e., uniform displacement or force, was strongly correlated with the relative magnitude of the strength bounds. Thus, explicit disc modeling may not be necessary.

Aged↗

A biomechanical analysis of the effects of resorption cavities on cancellous bone strength.

UNLABELLED: We evaluated the effects of resorption cavities on cancellous bone strength using computational methods. Adding cavities to cancellous bone caused reductions in strength and stiffness that were greater than expected from the associated changes in bone volume and more pronounced when cavities were targeted to regions of high tissue strain. INTRODUCTION: The amount of bone turnover in the skeleton has recently been implicated as a factor influencing bone strength. One mechanism proposed to explain this effect is that resorption cavities reduce the effective thickness of trabeculae and modify local stress distributions leading to reduced mechanical performance of the entire structure. In this study, we tested the plausibility of this mechanism. MATERIALS AND METHODS: High-resolution finite element models were created from muCT images of 16 vertebral cancellous bone samples, as well as from images of the samples in which cavities had been added digitally-either at regions of high strain (targeted) or placed at random on the bone surface (nontargeted). The effect of resorption cavities on predicted bone strength and stiffness was evaluated by comparing the relationships between mechanical properties and bone volume fraction among the three groups (the original images, those with nontargeted cavities, and those with targeted cavities). RESULTS: Addition of resorption cavities modified the relationship between mechanical properties and bone volume fraction in the finite element models such that, for a given bone volume fraction, stiffness and yield strength were reduced compared with the original images (p < 0.05). The differences in yield strength-volume fraction relationships between the original models and those with targeted cavities were significantly greater than those between the original models and those with nontargeted cavities (p < 0.05). None of the differences in predicted mechanical properties per unit bone volume fraction could be accounted for by 3D measures of microarchitecture. CONCLUSIONS: Resorption cavities may influence cancellous bone strength and stiffness independent of their effect on bone volume. The effects of cavities on bone mechanical performance relative to bone volume are greater when cavities are targeted to regions of high strain and cannot be predicted using standard microarchitecture measures.

Aged↗

Cortical and trabecular load sharing in the human vertebral body.

UNLABELLED: The biomechanical role of the vertebral cortical shell remains poorly understood. Using high-resolution finite element modeling of a cohort of elderly vertebrae, we found that the biomechanical role of the shell can be substantial and that the load sharing between the cortical and trabecular bone is complex. As a result, a more integrative measure of the trabecular and cortical bone should improve noninvasive assessment of fracture risk and treatments. INTRODUCTION: A fundamental but poorly understood issue in the assessment of both osteoporotic vertebral fracture risk and effects of treatment is the role of the trabecular bone and cortical shell in the load-carrying capacity of the vertebral body. MATERIALS AND METHODS: High-resolution microCT-based finite element models were developed for 13 elderly human vertebrae (age range: 54-87 years; 74.6 +/- 9.4 years), and parameter studies-with and without endplates-were performed to determine the role of the shell versus trabecular bone and the effect of model assumptions. RESULTS: Across vertebrae, whereas the average thickness of the cortical shell was only 0.38 +/- 0.06 mm, the shell mass fraction (shell mass/total bone mass)-not including the endplates-ranged from 0.21 to 0.39. The maximum load fraction taken by the shell varied from 0.38 to 0.54 across vertebrae and occurred at the narrowest section. The maximum load fraction taken by the trabecular bone varied from 0.76 to 0.89 across vertebrae and occurred near the endplates. Neither the maximum shell load fraction nor the maximum trabecular load fraction depended on any of the densitometric or morphologic properties of the vertebra, indicating the complex nature of the load sharing mechanism. The variation of the shell load-carrying capacity across vertebrae was significantly altered by the removal of endplates, although these models captured the overall trend within a vertebra. CONCLUSIONS: The biomechanical role of the thin cortical shell in the vertebral body can be substantial, being about 45% at the midtransverse section but as low as 15% close to the endplates. As a result of the complexity of load sharing, sampling of only midsection trabecular bone as a strength surrogate misses important biomechanical information. A more integrative approach that combines the structural role of both cortical and trabecular bone should improve noninvasive assessment of vertebral bone strength in vivo.

Aged↗

Trabecular microfracture and the influence of pyridinium and non-enzymatic glycation-mediated collagen cross-links.

The propensity of individual trabeculae to fracture (microfracture) may be important clinically since it could be indicative of bone fragility. Whether or not an overloaded trabecula fractures is determined in part by its structural ductility, a mechanical property that describes how much deformation a trabecula can sustain. The overall goal of this study was to determine the structural ductility of individual trabeculae and the degree to which it is influenced by pyridinium and non-enzymatic collagen cross-links. Vertically oriented rodlike trabeculae were taken from the thoracic vertebral bodies of 32 cadavers (16 male and 16 female, 54 - 94 years of age). A total of 221 trabeculae (4 - 9 per donor) were tested to failure in tension using a micro-tensile loading device. A subset of 76 samples was analyzed to determine the concentration of hydroxylysyl-pyridinoline (HP) and lysyl-pyridinoline (LP) cross-links as well as pentosidine, a marker of non-enzymatic glycation. Structural ductility (defined as the ultimate strain of the whole trabecula) ranged from 1.8% to 20.2% strain (8.8 +/- 3.7%, mean +/- SD) and did not depend on age (P = 0.39), sex (P = 0.57), or thickness of the sample at the point of failure (P = 0.36). Pentosidine was the only marker of collagen cross-linking measured that was found to be correlated with structural ductility (P = 0.01) and explained about 9% of the observed variance. We conclude that the ductility of individual trabeculae varies tremendously, can be substantial, and is weakly influenced by non-enzymatic glycation.

Age Factors↗

Development of residual strains in human vertebral trabecular bone after prolonged static and cyclic loading at low load levels.

Development of irreversible residual strains in trabecular bone may be a mechanism by which age-related non-traumatic vertebral fractures occur. To investigate this concept, static and cyclic loading tests were conducted at low loading levels for cylindrical cores of cadaveric vertebral trabecular bone. Stresses were applied equivalent to elastic strains of either 750 or 1,500 microstrain. Creep strains were measured during the tests, which lasted for 125,000 seconds (about 35 h), and for an additional 125,000 seconds after complete unloading. Emphasis was placed on the residual strains that developed, defined as the strain remaining at the end of the unloading phase. The results indicated that appreciable residual strains did develop, and were similar for static and cyclic loading. Irrespective of the applied load levels and loading modes, the residual strains that remained after the unloading phase were similar in magnitude to the originally applied elastic strain. Extrapolation of the observed residual strains to full recovery indicated that the time that would be required for full recovery was over 20 times longer than the duration of the applied loads. These results indicate that human vertebral trabecular bone does not creep in a linear viscoelastic fashion at low stress levels, and that creep mechanisms dominate the residual strains regardless of the loading mode. Taken together, these findings support the concept that non-traumatic vertebral fractures may be related to long-term creep effects because the trabecular bone does not have sufficient time to recover mechanically from creep deformations accumulated by prolonged static or cyclic loading.

Aged↗

Sensitivity of multiple damage parameters to compressive overload in cortical bone.

Damage accumulation plays a key role in weakening bones prior to complete fracture and in stimulating bone remodeling. The goal of this study was to characterize the degradation in the mechanical properties of cortical bone following a compressive overload. Longitudinally oriented, low-aspect ratio specimens (n=24) of bovine cortical bone were mechanically tested using an overload-hold-reload protocol. No modulus reductions greater than 5% were observed following overload magnitudes less than 0.73% strain. For each specimen, changes in strength and Poisson's ratio were greater (p=0.02) than that in modulus by 10.8- and 26.6-fold, respectively, indicating that, for the specimen configuration used in this study, longitudinal elastic modulus is one of the least sensitive properties to a compressive overload. Residual strains were also proportionately greater by 6.4-fold (p=0.01) in the transverse than axial direction. These results suggest that efforts to relate microcrack density and morphology to changes in compressive mechanical properties of cortical bone may benefit from considering alternative parameters to modulus reductions.

Adaptation, Physiological↗

Relationship between axial and bending behaviors of the human thoracolumbar vertebra.

STUDY DESIGN: The authors studied the mechanical behavior of vertebrae through the use of finite element analyses. OBJECTIVES: To determine the relation between axial and bending rigidity, and to determine the geometric and densitometric factors that affect this relation. SUMMARY OF BACKGROUND DATA: Metrics of vertebral body mechanical properties in bending have not been established despite evidence that anterior bending loads play a significant role in osteoporotic vertebral fracture. METHODS: Voxel-based finite element models were generated using quantitative computed tomography (QCT) scans of 18 human cadaveric vertebral bodies, and both axial and bending rigidities of the vertebra were computed. Both rigidity measures and their ratio were correlated with vertebral geometric and densitometric factors obtained from the QCT scans. RESULTS: Bending rigidity was moderately correlated with axial rigidity (r2 = 0.69) and strongly correlated with the product of axial rigidity and vertebral anteroposterior depth squared (r2 = 0.88). The ratio of bending to axial rigidity was independent of bone mineral density (P = 0.20) but was moderately correlated with the square of vertebral depth (r2 = 0.69). CONCLUSIONS: Vertebral anteroposterior depth plays an important role in bending rigidity. The scatter in the correlation between bending and axial rigidity suggests that some individuals can have vertebrae with a normal axial stiffness but an abnormally low bending stiffness. Because whole-bone stiffness is indicative of bone strength, these results support the concept that use of more than one metric of vertebral strength, for example, compression and bending strengths, may improve osteoporotic fracture risk prediction.

Adult↗

Contribution of inter-site variations in architecture to trabecular bone apparent yield strains.

Apparent yield strains for trabecular bone are uniform within an anatomic site but can vary across site. The overall goal of this study was to characterize the contribution of inter-site differences in trabecular architecture to corresponding variations in apparent yield strains. High-resolution, small deformation finite element analyses were used to compute apparent compressive and tensile yield strains in four sites (n = 7 specimens per site): human proximal tibia, greater trochanter, femoral neck, and bovine proximal tibia. These sites display differences in compressive, but not tensile, apparent yield strains. Inter-site differences in architecture were captured implicitly in the model geometries, and these differences were isolated as the sole source of variability across sites by using identical tissue properties in all models. Thus, the effects inter-site variations in architecture on yield strain could be assessed by comparing computed yield strains across site. No inter-site differences in computed yield strains were found for either loading mode (p > 0.19), indicating that, within the context of small deformations, inter-site variations in architecture do not affect apparent yield strains. However, results of ancillary analyses designed to test the validity of the small deformation assumption strongly suggested that the propensity to undergo large deformations constitutes an important contribution of architecture to inter-site variations in apparent compressive yield strains. Large deformations substantially reduced apparent compressive, but not tensile, yield strains. These findings indicate the importance of incorporating large deformation capabilities in computational analyses of trabecular bone. This may be critical when investigating the biomechanical consequences of trabecular thinning and loss.

Adult↗

Mechanisms of uniformity of yield strains for trabecular bone.

Variations in yield strains for trabecular bone within a specific anatomic site are only a small fraction of the substantial variations that exist for elastic modulus and strength, and yet the source of this uniformity is not known. Our goal was to investigate the underlying mechanisms by using high-resolution, materially nonlinear finite element models of 12 human femoral neck trabecular bone specimens. The finite element models, used to obtain apparent yield strains in both tension and compression, assumed that the tissue-level yield strains were the same across all specimens. Comparison of the model predictions with the experimental data therefore enabled us to isolate the combined roles of volume fraction and architecture from the role of tissue material properties. Results indicated that, for both tensile and compressive loading, natural variations in volume fraction and architecture produced a negligible coefficient of variation (less than 3%) in apparent yield strains. Analysis of tissue-level strains showed that while bending of individual trabeculae played only a minor role in the apparent elastic behavior, the combined effects of this bending and tissue-level strength asymmetry produced apparent-level failure strains in compression that were 14% lower than those at the tissue level. By contrast, tissue and apparent-level yield strains were equivalent for tensile loading. We conclude that the uniformity of apparent yield strains is primarily the result of the highly oriented architecture that minimizes bending. Most of the variation that does occur is the result of the non-uniformity of the tissue-level yield strains.

Aged↗

Similarity in the fatigue behavior of trabecular bone across site and species.

Within the context of improving knowledge of the structure-function relations for trabecular bone for cyclic loading, we hypothesized that the S-N curve for cyclic compressive loading of trabecular bone, after accounting for differences in monotonic strength behavior, does not depend on either site or species. Thirty-five cores of fresh-frozen elderly human vertebral trabecular bone, harvested from nine donors (mean+/-S.D., age=74+/-17 years), were biomechanically tested in compression at sigma/E(0) values (ratio of applied stress to pre-fatigue elastic modulus) ranging from 0.0026 to 0.0070, and compared against literature data (J. Biomech. Eng. 120 (1998) 647-654) for young bovine tibial trabecular bone (n=37). As reported for the bovine bone, the number of cycles to failure for the human vertebral bone was related to sigma/E(0) by a power-law relation (r(2)=0.54, n=35). Quantitative comparison of these data against those reported for the bovine bone supported our hypothesis. Namely, when the differences in mean monotonic yield strain between the two types of bone were accounted for, a single S-N curve worked well for the pooled data (r(2)=0.75, n=72). Since elderly human vertebral and young bovine tibial trabecular bone represent two very different types of trabecular bone in terms of volume fraction and architecture, these findings suggest that the dominant failure mechanisms in trabecular bone for cyclic loading occur at the ultrastructural level.

Adaptation, Physiological↗