PubMed Health⌕ Search

Biomedical subjects

Torsten Jemt

Publications and source records attributed to Torsten Jemt.

21 records · Page 2Linked to original sources

Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study.

PURPOSE: This study evaluated and compared the clinical performance of laser-welded titanium fixed partial implant-supported prostheses with that of conventional cast frameworks in the partially edentulous jaw. MATERIALS AND METHODS: Forty-two patients provided with Brånemark system implants were arranged into two groups. Twenty-one patients (group A) were provided with a conventional cast ceramometal framework in one side of the jaw and a laser-welded titanium framework with low-fusing porcelain in the other side. In group B, 21 patients received a titanium framework prosthesis to replace a conventional implant prosthesis. Clinical and radiographic data were collected for 5 years. RESULTS: Four implants and one titanium framework were lost during the follow-up period. The two framework designs did not show any significant differences with regard to implant or prosthesis survival (P > .05). Few clinical complications were observed. In group A, marginal bone loss after 5 years was similar for both prosthesis designs, with an average of 0.1 mm and 0.3 mm in the maxilla and mandible, respectively. Basically, no bone loss was observed on average in group B. Furthermore, no significant relationship was observed between marginal bone loss and placement of prosthesis margin or prosthesis design. CONCLUSION: Except for an insignificant tendency toward a slightly higher incidence of small chips of porcelain veneers, laser-welded titanium frameworks presented an overall similar clinical performance as conventional cast frameworks in partial implant situations after 5 years.

Adult↗

Implant treatment in the edentulous mandible: a prospective study on Brånemark system implants over more than 20 years.

PURPOSE: This prospective investigation studied the clinical and radiographic performance of mandibular fixed prostheses supported by osseointegrated implants over more than 20 years. MATERIALS AND METHODS: A total of 273 standard Brånemark implants (10 mm long) were placed in 47 patients between 1978 and 1982. Clinical and radiographic data collected at several examinations over the 20-year observation period have been reported previously. This study presents the outcome of the latest follow-up after 20 to 23 years. RESULTS: Thirty patients (64%; 75% of those still alive) attended the 20-year follow-up examination. Three implants were lost during the entire observation period, and the 20-year implant cumulative survival rate was 98.9%. All patients had continuous prosthesis function, but two had their mandibular prostheses remade during the 20 years. No implants or prostheses were lost or fractured during the last 5 years, and only a few prosthodontic complications were noted. The mean bone level was 1.6 mm (SD 0.90) below the reference point after 20 years, and mean bone loss was 0.2 mm (SD 0.22) between the 15- and 20-year follow-ups. Thirty-seven implants (24%) showed more than two exposed threads at the 15-year follow-up examination, but only four implants (3%) presented pain and/or bone loss exceeding one thread (0.6 mm) during the last 5 years. CONCLUSION: The successful treatment result after 15 years continued up to more than 20 years in function. During the last 5 years, a majority of the implants with several exposed implant threads could be maintained without any complications, and the frequency of implants showing signs of ongoing peri-implantitis was less than 3%.

Adult↗

Evaluation of custom-made procera ceramic abutments for single-implant tooth replacement: a prospective 1-year follow-up study.

PURPOSE: The aim of this study was to evaluate the clinical performance of customized ceramic single-implant abutments in combination with two different techniques for fabricating crowns. MATERIALS AND METHODS: Twenty consecutive patients were provided with 24 single-implant restorations with customized ceramic abutments. The restorations were either cemented to the abutment (n = 13) or fabricated with the veneering material fused directly onto the ceramic abutment (n = 11). The patients were evaluated at 6 and 12 months with radiographs and clinical parameters for complications and soft tissue response. RESULTS: All implants and restorations were still in function after 1 year. Few clinical problems were reported during the follow-up period. The interproximal soft tissue recovered to near normal size. The mean marginal bone loss was similar for both groups, reaching an average of 0.3 mm (SD 0.71) after 1 year in function. CONCLUSION: The short-term results indicate that customized ceramic abutments are successful and have comparable function, regardless of fabrication method.

Adolescent↗