PubMed Health⌕ Search

Biomedical subjects

Toshiaki Sekita

Publications and source records attributed to Toshiaki Sekita.

2 recordsLinked to original sources

Effect of denture adhesive on stability of complete dentures and the masticatory function.

This study examines the effects of denture adhesive on the retention and stability of complete dentures and the masticatory function. The authors estimated the stability of complete dentures from 3-dimensional (3-D) denture movement and rotational denture movement and additionally the masticatory function from cycle time and chewing time. Six edentulous subjects who participated in this study had old and newly fabricated complete dentures. Upper denture movement was recorded using a 3-D motion capture system while chewing 3 kinds of food (peanuts, fish paste, raisins). Both the new and old dentures showed that using a denture adhesive contributes to reducing 3-D denture movement, rotational denture movement and chewing time during chewing the various foods. The cycle time in new and old dentures was statistically unaffected by applying denture adhesive. There was no statistically significant difference in improvement in 3-D denture movement or rotational denture movement between the new and old dentures, for any of the foods. This study observes the overall effect of denture adhesive during use for both dentures. The results of this study suggest that denture adhesive contributes to reducing denture movement and so improves chewing function.

Adhesives↗

[Fundamental study on the development of a measuring device using an accelerometer].

It is important to clarify stomatognathic functions. To diagnose them, some measuring devices, such as MKG and the Gnatho-hexagraph, were developed. Such equipment, however, is not widely diffused, due to cost. The purpose of this fundamental study was to obtain information on position using an accelerometer. This system consists of a micro dual-axis accelerometer and a peripheral interface controller. Two-dimensional acceleration, velocity, and movement can be calculated by a computer. We examined the accuracy of this system using a laser measuring device. The result was as follows: The accuracy of the system was 0.03 (p-p values) using acceleration of gravity and a frequency of 72.5 Hz. In the present study, mandibular movements during chewing raisins were analyzed using this system. The new system demonstrated its value for analyzing mandibular movements.

Acceleration↗