PubMed Health⌕ Search

Biomedical subjects

Toshiyo Tamura

Publications and source records attributed to Toshiyo Tamura.

12 recordsLinked to original sources

Improving the accuracy of pedometer used by the elderly with the FFT algorithm.

PURPOSE: The aim of this study was to investigate and improve the accuracy of accelerometer-type pedometers used by the elderly with slow walking speeds, with or without gait disorders, who do or do not use a cane. METHODS: Eighteen subjects walked with a cane (5 males, 13 females; age, 80.9 +/- 7.7 yr; height, 148.1 +/- 7.7 cm; weight, 51.8 +/- 8.8 kg (mean +/- SD); nine had impaired gait), and 31 subjects walked without a cane (7 males, 24 females; age, 80.9 +/- 7.7 yr; height, 148.1 +/- 7.7 cm; weight, 51.8 +/- 8.8 kg; 15 had impaired gait). Subjects walked for approximately 20 m (10 m in each direction and a turning arc) at their own speed. We determined the number of steps by pedometer (PM), by visually counting the actual number of steps (RM), and by the triaxial acceleration signals. The power spectrum of the accelerometer in each direction calculated by fast Fourier transform (FFT) for a 4-s temporal window was normalized with the maximum power of each window. It was composited, and the frequency at maximum power was considered as the cadence. The number of steps taken (FM) was determined by summing all the estimated steps in each window. RESULTS: PM was significantly less than the RM (P < 0.05), and the error of PM was 53.2 +/- 34.1% of RM. FM did not differ from the RM, and the average error of FM was -0.7 +/- 7.9% of RM (absolute value: 5.8 +/- 5.3%). CONCLUSION: We suggest that our FFT method is suitable for estimating the number of steps during walking in this population.

Acceleration↗

Low-cost, email-based system for self blood pressure monitoring at home.

We have developed a low-cost monitoring system, which allows subjects to send blood pressure (BP) data obtained at home to health-care professionals by email. The system consists of a wrist BP monitor and a personal computer (PC) with an Internet connection. The wrist BP monitor includes an advanced positioning sensor to verify that the wrist is placed properly at heart level. Subjects at home can self-measure their BP every day, automatically transfer the BP data to their PC each week, and then send a comma-separated values (CSV) file to their health-care professional by email. In a feasibility study, 10 subjects used the system for a mean period of 207 days (SD 149). The mean percent achievement of measurement in the 10 subjects was 84% (SD 12). There was a seasonal variation in systolic and diastolic BP, which was inversely correlated with temperature. Eight of the 10 subjects evaluated the system favourably. The results of the present study demonstrate the feasibility of our email-based system for self-monitoring of blood pressure. Its low cost means that it may have widespread application in future home telecare studies.

Aged↗

Fractal dynamics of body motion in patients with Parkinson's disease.

In this paper, we assess the complexity (fractal measure) of body motion during walking in patients with Parkinson's disease. The body motion of 11 patients with Parkinson's disease and 10 healthy elderly subjects was recorded using a triaxial accelerometry technique. A triaxial accelerometer was attached to the lumbar region. An assessment of the complexity of body motion was made using a maximum-likelihood-estimator-based fractal analysis method. Our data suggest that the fractal measures of the body motion of patients with Parkinson's disease are higher than those of healthy elderly subjects. These results were statistically different in the X (anteroposterior), Y (lateral) and Z (vertical) directions of body motion between patients with Parkinson's disease and the healthy elderly subjects (p < 0.01 in X and Z directions and p < 0.05 in Y direction). The complexity (fractal measure) of body motion can be useful to assess and monitor the output from the motor system during walking in clinical practice.

Acceleration↗

Is an entertainment robot useful in the care of elderly people with severe dementia?

OBJECTIVE: An entertainment robot was used as occupational therapy instead of animal-assisted therapy to avoid any danger or injury to the patient and maintain cleanliness. This study compared the effectiveness of a robot animal, AIBO, with a toy. METHOD: AIBO is made of metal and responds to spoken commands. We demonstrated AIBO to severely demented elderly people living in a geriatric home and observed their reactions. RESULTS: The most frequent reactions to AIBO consisted of looking at, communicating with, and caring for AIBO. The patients recognized that AIBO was a robot. However, once we dressed AIBO, the patients perceived AIBO as either a dog or a baby. Nevertheless, the presentation of AIBO resulted in positive outcomes for the severe dementia patients, including increased communication between the patients and AIBO. CONCLUSION: AIBO was clearly an effective rehabilitation tool in the treatment of severely demented patients.

Aged↗

Developing an instrument to support oral care in the elderly.

BACKGROUND: The dramatic increase in the number of dependent elderly in developed countries has created a great need for their improved oral care. However, optimal oral care by caregivers is not possible because of time constraints, difficulty involved in brushing other individuals' teeth, lack of co-operation, and the lack of perceived need. Therefore, the development of an effective instrument simplifying and supporting oral care to relieve the strain on caregivers is a matter of some urgency. PURPOSE: In order to clean the mouths of elderly dependent patients, we have developed a new oral care support instrument (an electric toothbrush in combination with an antibacterial-agent supply and suction system). The purpose of the present study was to develop and evaluate a new oral care support instrument. METHODS: a) Plaque removal study: The plaque- removing ability of this new instrument in 70 outpatients was compared with the Plak Control D9011 (Braun Gillette Japan Inc.) as a control by means of the Turesky modification of the Quigley and Hein plaque index. b) Clinical study: The subjects were 10 dependent elderly who received oral care using the new oral care support instrument for two weeks. The plaque and gingival indices were used for clinical evaluations. RESULTS: a) Plaque removal study: Brushing with the new oral care support instrument removed significantly more plaque than with the Plak Control D9011. b) Clinical study: The new oral care support instrument allows a more effective removal of dental plaque and shows a significant improvement in the gingival indices in dependent elderly. CONCLUSION: It is concluded that the new oral care support instrument is effective and can be recommended for oral care in the dependent elderly.

Administration, Topical↗

[The assistive device in self-support for the elderly--role of assistive devices as independence from the physical and mental restrictions].

The development of assistive self-support devices was an important strategy for improving quality of life in the elderly. After introduction of care insurance, independence from the physical and metal restrictions was recommended. In order to improve quality of life and independence form restrictions, we have developed several assistive devices. A baby-doll mimicking a baby was made add applied to the therapeutic program. This doll therapy has been used in several facilities for healing elderly, especially dementia patients. To prevent falls, a power-assisted walker was developed to compensate and support elderly gait. A fall detector was used to estimate falling and to develop guidelines for the prevention of fall.

Accidental Falls↗

Discrimination of walking patterns using wavelet-based fractal analysis.

In this paper, we attempted to classify the acceleration signals for walking along a corridor and on stairs by using the wavelet-based fractal analysis method. In addition, the wavelet-based fractal analysis method was used to evaluate the gait of elderly subjects and patients with Parkinson's disease. The triaxial acceleration signals were measured close to the center of gravity of the body while the subject walked along a corridor and up and down stairs continuously. Signal measurements were recorded from 10 healthy young subjects and 11 elderly subjects. For comparison, two patients with Parkinson's disease participated in the level walking. The acceleration signal in each direction was decomposed to seven detailed signals at different wavelet scales by using the discrete wavelet transform. The variances of detailed signals at scales 7 to 1 were calculated. The fractal dimension of the acceleration signal was then estimated from the slope of the variance progression. The fractal dimensions were significantly different among the three types of walking for individual subjects (p < 0.01) and showed a high reproducibility. Our results suggest that the fractal dimensions are effective for classifying the walking types. Moreover, the fractal dimensions were significantly higher for the elderly subjects than for the young subjects (p < 0.01). For the patients with Parkinson's disease, the fractal dimensions tended to be higher than those of healthy subjects. These results suggest that the acceleration signals change into a more complex pattern with aging and with Parkinson's disease, and the fractal dimension can be used to evaluate the gait of elderly subjects and patients with Parkinson's disease.

Acceleration↗

Influence of cool-down exercise on autonomic control of heart rate during recovery from dynamic exercise.

The recovery of post-exercise heart rate (HR) is enhanced by a procedure of cooling down; however, the mechanism of this facilitated reduction is unknown. To determine whether more cardiac vagal reactivation is associated with a decrease in HR following cool-down exercise, we examined high-frequency R-R interval variability (HF, 0.15-0.40 Hz), an index of cardiac vagal tone, in six young healthy male subjects with a comparison between sitting rest after 6 minutes of cool-down cycling at 20% peak oxygen uptake (VO2peak) and sitting complete rest, following 5 min of upright cycle exercise at 70% VO2peak. During the last minute of exercise, there was no difference in HR between the two exercise tests before performing or not performing cool-down exercise (mean +/- SE, 148.7 +/- 6.9 versus 149.7 +/- 7.0 beats/min, respectively, by a Wilcoxon signed-ranks test). After exercise, a similar initial rapid decrease in HR and subsequent decline was observed during the first 6 min of recovery, regardless of cool-down exercise. However, the resting HR average following cool-down exercise was significantly lower than the corresponding HR without cool-down exercise (92.1 +/- 3.0 versus 100.8 +/- 3.6 beats/min, P < 0.05). The corresponding HF amplitude was slightly, but significantly greater with than without cool-down exercise (10.6 +/- 2.2 versus 9.0 +/- 1.9, P < 0.05). Thus the increase in HF amplitude corresponded to a decrease in resting HR following cool-down exercise, as compared to complete rest without cool-down exercise. Therefore, we conclude that after moderate exercise, the decrease in resting HR following cool-down exercise is associated with an increase in cardiac vagal tone.

Adaptation, Physiological↗

Development and evaluation of a simple calorimeter for the measurement of resting metabolism.

1. A simple calorimeter based on the measurement of oxygen uptake has been developed. 2. A respiratory simulator was used to evaluate oxygen uptake at different flow rates. A known concentration of mixed gases flows into the calorimeter via the respiratory simulator. Oxygen concentration and flow rate were measured and stored to memory for further analysis. 3. Results indicate that large errors occur at low flow rates, but that the error is less than 5% under normal conditions. 4. This device can be used to measure oxygen uptake under resting conditions.

Calorimetry, Indirect↗