PubMed Health⌕ Search

Biomedical subjects

Toshizo Katsuda

Publications and source records attributed to Toshizo Katsuda.

3 recordsLinked to original sources

Sonographic appearance of the normal appendix in adults.

OBJECTIVE: To evaluate the sonographic visualization of the normal adult appendix, a large series of sonographic images from consecutive asymptomatic patients was analyzed. METHODS: A total of 788 consecutive adult patients (402 male and 386 female; median age +/- SD, 51.1 +/- 17.2 years; range, 16-91 years) were examined by appendiceal transabdominal sonography with tissue harmonic imaging. The detection rate, outer appendiceal diameter, intraluminal content, and location of the appendix were estimated. The overall normal appendix was separated into appendix-visualized and appendix-not-visualized groups, which were then examined for the relationship with abdominal wall thickness, body mass index (in kilograms per square meter), age, and sex. RESULTS: The normal appendix was detected in 388 (49.2%) of 788 patients. The outer appendiceal diameter +/- SD was 4.27 +/- 1.2 mm (range, 1.0-11.1 mm). In 291 (75%) of the 388 patients, appendices could be depicted in the intra-luminal gas during sonography. The location of the appendix was classified according to the appendiceal tip, which was found to be abdominal in 37 (9.5%), pelvic in 291 (75%), retrocecal in 23 (6.0%), and a midline extension in 37 (9.5%). In both body mass index and abdominal wall thickness, significant differences were found between appendix-visualized and appendix-not-visualized cases (P < .05). There was no significant difference in age (P = .37) or sex (P = .23) between appendix-visualized and appendix-not-visualized cases. CONCLUSIONS: The results show that the normal adult appendix can be revealed by sonographic visualization in a large series of asymptomatic patients.

Adolescent↗

Usefulness of a pulse oximeter for enhancing breath holding in hepatic subtraction angiography.

This study examined the usefulness of a pulse oximeter in hepatic digital subtraction angiography (DSA) with oxygen administration for breath holding. Oxygen saturation and dissociation times were measured using a pulse oximeter. Twenty-eight patients inhaled oxygen at a rate of 3 liters/min through a nasal tube. Saturation times ranged from 0 to 140 seconds to achieve arterial oxygen-hemoglobin saturation of almost 100%. Dissociation times ranged from 0 to 600 seconds after oxygen termination.

Aged↗

Verification imaging using a computed radiography system for high-energy electron beam therapy.

PURPOSE: The aim of this study was to examine a method to more conveniently acquire verification images. A computed radiography (CR) system was employed using a photostimulable phosphor plate and diagnostic cassette used for taking diagnostic X-ray photographs. MATERIALS AND METHODS: Verification images were acquired using the diagnostic cassette and therapy cassette. Image processing parameters were adjusted to improve the image quality. Verification images were printed using optimum parameters, and 10 radiation technicians visually evaluated the images. The sign test was used, and image quality was evaluated using a two-sided test at a 5% level of significance. To assess its clinical value, a radiation oncologist evaluated patient verification images. RESULTS: Verification image quality was improved by the adjustment of image processing parameters. As a result of the image quality evaluation, there were no significant differences between the two types of cassette (p>0.05). In most of the clinical cases (98%), the verification images were useful. CONCLUSION: We found that good quality verification images were acquired by a CR system with a diagnostic cassette. This system is suitable for practical use to acquire daily verification images, and it is considered useful for maintaining quality assurance (QA) in high-energy electron beam therapy.

Humans↗