PubMed Health⌕ Search

Biomedical subjects

Trent D Ridder

Publications and source records attributed to Trent D Ridder.

2 recordsLinked to original sources

Framework for multivariate selectivity analysis, part I: theoretical and practical merits.

A number of definitions of multivariate selectivity have been proposed in the literature. Arguably, the one that enjoys the greatest chemometric attention has been the net analyte signal (NAS) based definitions of Lorber and Zinn. Recent works have suggested that similar inference can be made for inverse least-squares calibration methods (e.g., principal components regression). However, the properties of inverse calibration methods are markedly different than classical methods, so in many practical cases involving inverse models classically derived figures of merit cannot be transparently interpreted. In Part I of this work, we discuss a selectivity framework that is theoretically consistent regardless of the calibration method. Importantly, it is also experimentally measurable, either through controlled selectivity experiments, or through analysis on opportunistically acquired sample measurements. It is statistically advantageous to use the former if such control is achievable. Selectivity is defined to be a function of the change in predicted analyte concentration that will result from a change in the concentration of an interferant, an approach consistent with traditional definitions of analytical selectivity and National Committee for Clinical Laboratory Standards recommendations for interference testing. Unlike the NAS-based definition of selectivity, the definition discussed herein is relevant to only a particular analyte-interferant pair. The theoretical and experimental aspects of this approach are illustrated with simulated data herein and in Part II of this paper, which investigates several experimental near-infrared data sets.

Algorithms↗

Framework for multivariate selectivity analysis, part II: experimental applications.

In Part I of this paper, a framework for multivariate selectivity was introduced that is both calculable from first principles and experimentally tractable. In this part, we employ the proposed selectivity framework for analyzing both in vitro and in vivo near-infrared experimental data. Two in vitro data sets are used to compare different methods for estimating selectivity and to demonstrate the benefits obtained from validation data with expanded interferant concentration ranges. The in vitro data also demonstrate that the experimentally estimated selectivities provide insights into the properties of the calibration models that are difficult or impossible to infer by other means. The merits of the proposed selectivity function are further demonstrated using a complex in vivo application: the noninvasive measurement of ethanol in humans. Results indicate that in vivo calibration model sensitivity, selectivity, and concentration correlations can be systematically interrogated using the proposed selectivity framework and judicious use of experimental measurements. These analyses not only provide selectivity and sensitivity information, but also the variance components of the total MSEP, which is invaluable information for both method development and analytical method characterization.

Algorithms↗