PubMed Health⌕ Search

Biomedical subjects

Trudy A Meinberg

Publications and source records attributed to Trudy A Meinberg.

5 recordsLinked to original sources

Pulp responses to precise thermal stimuli in dentin-sensitive teeth.

The purpose of this study was to determine whether pulpal responses to cold temperatures applied to enamel, using a method that precisely controls the intensity of the cold stimulus or measures the response time, could distinguish dentin-sensitive teeth from nonsensitive teeth. Eighteen human subjects were stimulated with cold temperatures decreasing in 5 degree C intervals (and with tetrafluoroethane) on exposed root and enamel of a dentin-sensitive tooth and enamel of a contralateral nonsensitive tooth. Pain threshold, intensity of pain, time to pain onset, and duration of pain at baseline, 4 h, 8 h, and 1 week were measured. Responses to enamel stimulation of sensitive teeth compared with the nonsensitive teeth usually were highly correlated and not significantly different. The exception was a longer duration of pain in the dentin-sensitive teeth (4.62 +/- 0.47 s) compared with nonsensitive teeth (2.92 +/- 0.49 s; p = 0.016) after enamel stimulation with tetrafluoroethane. Longitudinal studies are necessary to determine whether these slight increases in pain duration indicate an increased probability of pulpal degeneration or need for dentin protection.

Cold Temperature↗

Local biochemical markers of bone turnover: relationship to subsequent density of healing alveolar bone defects.

OBJECTIVES: This pilot study was designed to test whether biochemical markers of bone turnover in washes of periosteal or trabecular alveolar bone surfaces could be correlated with increases in bone density of an adjacent healing implant socket. METHODS: Ten subjects had a canula inserted into the alveolar crest and sterile phosphate-buffered saline was washed over the periosteal and trabecular surfaces and collected. Surgical flaps were reflected, 5 mm diameter bone cores were removed from the bone wash site, and standardized radiographs were taken. The sites were allowed to heal for 12 weeks, and radiographs were repeated. Bone washes of the healing sites were also collected after 2 and 12 weeks. Washes were analysed for bone turnover markers osteocalcin (OC; radioimmunoassay) and C-terminal telopeptide of Type 1 collagen (ICTP; enzyme-linked immunosorbent assay (ELISA)), and blood component albumin (ALB; ELISA). Changes in bone density during healing were determined by radiographic absorptiometry. RESULTS: OC/ALB and ICTP/ALB ratios were higher for trabecular than periosteal washes at baseline (p<or=0.01). Trabecular OC/ALB and ICTP/ALB were inversely correlated with increasing bone density of the healing bone core socket (r=-0.72, p=0.03; Pearson's correlation coefficient). CONCLUSIONS: Biochemical markers of bone turnover in bone washes of specific alveolar bone sites may prove helpful in predicting how the bone density will increase around healing dental implants.

Absorptiometry, Photon↗

Effect of narcotic pain reliever on pulp tests in women.

The purpose of this study was to determine the effect of one dose of a common narcotic-based pain reliever (Vicodin) on a battery of oral sensitivity tests across time in women. Fifteen Caucasian women randomly were given an oral dose of 10 mg of hydrocodone/1000 mg of acetaminophen or placebo in a double-blind, cross-over design. At baseline (before drug) and after 2, 4, and 8 h each subject was evaluated for sensitivity thresholds with four tests around an experimental tooth: (a) electric pulp tester applied to exposed root; (b) electric pulp tester on adjacent mucosa; (c) increasing probe pressure (grams) on adjacent mucosa; and (d) decreasing cold probe (degrees C) on the exposed root. The outcomes of all tests were not statistically different between drug and placebo treatments at any time point (p > 0.05). These results suggest that a systemic dose of hydrocodone/acetaminophen has little impact on healthy pulp or mucosa sensitivity in women as measured by common diagnostic tests.

Acetaminophen↗

Comparison of conventional periodontal maintenance versus scaling and root planing with subgingival minocycline.

BACKGROUND: Alternative regimens using subgingival antimicrobials compared to conventional periodontal maintenance (PM) may lead to more efficient protocols. The purpose of this study was to evaluate treatment time and clinical and radiographic outcomes in 2 periodontitis cohorts, one receiving conventional PM and the other receiving scaling and root planing (SRP) and multiple doses of subgingival minocycline. METHODS: Moderate to advanced chronic periodontitis patients were concurrently treated with either: 1) scaling and root planing and 4 subgingival doses of minocycline microspheres in all > or = 5 mm pockets over a 6-month period (RP/M; n = 24 patients); or 2) conventional 3-month periodontal maintenance (PM; n = 24 patients). Clinical and radiographic measurements, including probing depth (PD), clinical attachment level (CAL), and interproximal bone height (BH), were analyzed in 2 premolar/molar interproximal > or = 5 mm pockets at baseline and 1 year using paired t tests, analysis of variance, chi-square analysis, and correlation coefficients. RESULTS: Baseline clinical and radiographic data were similar between RP/M and PM patients. Probing depths showed greater mean improvement in RP/M (0.9 +/- 0.1 versus 0.4 +/- 0.1 mm, P = 0.02), with 25% of subjects in RP/M gaining > or = 2 mm compared to 4.2% in PM (differences were statistically significant). The mean loss in bone height and percent subjects losing bone height were less in RP/M (0.05 +/- 0.05 mm; 12.5%) than PM (0.09 +/- 0.08 mm; 16.7%), but bone height differences were not statistically significant. A subset of RP/M molar furcation sites responded with similar PD reduction and no BH loss over 1 year. While cross-sectional RP/M data between CAL and BH, or PD and CAL were highly correlated, changes over 1 year were not correlated among any of these parameters. CONCLUSIONS: Scaling and root planing and subgingival minocycline in experimental sites took little time (<5 minutes/appointment), but resulted in more probing depth reduction and less frequent bone height loss than conventional periodontal maintenance.

Administration, Topical↗

Clinical evaluation of two adhesive composite cements for the suppression of dentinal cold sensitivity.

STATEMENT OF PROBLEMS: Postoperative cold sensitivity after the cementation of indirect restorations with composite cements has been reported frequently but not scientifically documented. PURPOSE: This controlled clinical study was designed to simulate the dentin/composite cement interface immediately after cementation of a cast restoration. The desensitizing capabilities of a composite cement that contains a self-etching, dual-polymerizing resin adhesive system were compared with those of a composite cement that use phosphoric acid etching followed by a single-bottle, light-activated primer/resin-based adhesive. MATERIAL AND METHODS: The hypersensitive root surfaces of selected teeth were randomized to receive 1 of 3 treatments: coating with a self-etching adhesive (Linkmax) and its respective cement, coating with a conventionally etched adhesive (RelyX ARC) and its cement, or no treatment (negative control). The sample size was 22. Dentin sensitivity was ascertained with an accurate cold testing device that slowly decreased in temperature. Tooth sensitivity was measured both immediately and at 7 days after placement. Two-way analysis of variance and Fisher's least significant difference test (P<.05) were used to determine whether significant differences existed as a function of treatment type or time. RESULTS: Immediately after placement, the self-etching adhesive and its respective cement resulted in more suppression of cold sensitivity than no treatment (control); with Linkmax treatment, the temperature at which teeth responded was reduced by 8.4 degrees C. The conventionally etched adhesive and its cement reduced the temperature at which teeth responded by 9.4 degrees C. After 1 week, these temperature reductions were 7.0 degrees C and 4.3 degrees C, respectively. Untreated controls at the 2 intervals showed a mean decrease in sensitivity to cold of 3.6 degrees C and 4.1 degrees C. Statistical analysis showed type of composite cement to be a significant factor. CONCLUSION: Within the limitations of this study and in comparison to untreated control teeth, Linkmax treatment resulted in a significant reduction in tooth root sensitivity over 1 week (P=.02), whereas RelyX ARC did not (P=.066).

Acid Etching, Dental↗