PubMed Health⌕ Search

Biomedical subjects

Tse-Chuan Chou

Publications and source records attributed to Tse-Chuan Chou.

21 records · Page 2Linked to original sources

Determination of albumin concentration by MIP-QCM sensor.

An MIP-QCM sensor able to detect micro-determine albumin concentrations was prepared by imprinting albumin with 3-dimethylaminopropyl methacrylamide-acrylate. The albumin MIP was coated on a QCM Au electrode. The adsorption characteristics of different electrodes, such as Au-OH, Au-COOH, Au-NH2 and Au electrodes, with albumin or mixture was examined. In the tetraethyleneglycol dimethacrylate crosslinking agent system, the adsorption capacity of different Au electrodes is in the order Au-OH > Au-COOH > Au-NH2 > Au. Additionally, the time taken to receive a steady-state frequency is in the order Au-NH2 < Au-OH < Au-COOH < Au. However, in the trimethylolpropane trimethacrylate crosslinking agent system, the adsorption capacity is in the order Au > Au-NH2 > Au-OH > Au-COOH electrode. Hence, the crosslinking agent had a significant effect on the MIP-QCM. On the adsorption selectivity, the albumin MIP-QCM exhibited higher response to albumin, the adsorption mass ratio of cytochrome c:lysozyme:albumin:myoglobin was 160:1:1942:30. On the other hand, in the non-MIP-QCM, the adsorption mass ratio of cytochrome c:lysozyme:albumin:myoglobin was 13:1:249:86. Additionally, a linear fitting was established and a clinical real sample was tested. This novel potential application of molecular imprinting to the recognition element of an MIP-QCM sensor appears to be promising.

Adsorption↗

Fabrication of glucose oxidase/polypyrrole biosensor by galvanostatic method in various pH aqueous solutions.

The pH effect of pyrrole electropolymerization in the presence of glucose oxidase (GODx) on the performance and characteristic of galvanostatically fabricated glucose oxidase/polypyrrole (Ppy) biosensor is reported. Preparing the GODx/Ppy biosensors in 0.1 M KCl saline solution with various pH containing 0.05 M pyrrole monomer and 0.5 mg/ml GODx at 382 microA/cm2 current density for 100 mC/cm2 film thickness, both the galvanostatic responses and characteristics of these resulted biosensors were obtained. The results revealed that the galvanostatic glucose biosensor fabricated at neutral pH condition exhibited much higher sensitivity than those fabricated at lower or higher pH conditions, and had a good linearity form zero to 10 mM glucose with the sensitivity of 7 nA/mM. Finally, the long-term stability and the kinetic parameters, Michaelis constant and maximum current, of this biosensor were also reported.

Biosensing Techniques↗

Comparing Nafion and ceramic separators used in electrochemical purification of spent chromium plating solutions: cationic impurity removal and transport.

This study focuses on the electrolytic regeneration of spent chromium plating solutions. These solutions contain a significant amount of chromium and a lesser amount of other heavy metals, which makes them a significant environmental concern and an obvious target for recycling and reuse. The type of separator used is extremely critical to the performance of the process because they are the major resistance in the transport-related impurity (Cu(II), Ni(II), and Fe(III)) removals from contaminated chromic acid solutions. A Nafion 117 membrane and a ceramic diaphragm separator traditionally used in the industry were tested for comparison. It was found that the mobilities of Cu(II) and Ni(II) were similar and higher than that of Fe(III) using both separators. The mobility of each cation was smaller in the Nafion membrane than in the ceramic diaphragm. The measured conductivity of the ceramic diaphragm was slightly higher than that of Nafion membrane. However, the Nafion membrane was much thinner than the ceramic diaphragm resulting in the system using the Nafion membrane having higher impurity removal rates than the system using the ceramic diaphragm. The removal rates were approximately equal for Cu(II) and Ni(II) and lowest for Fe(III). Both current and initial concentration affected the removal rates of the impurities. Modeling results indicated that a system using a Nafion separator and a small catholyte/anolyte volume ratio was better than a system using a ceramic separator for removing impurities from concentrated plating solutions if the impurities transported into the catholyte are deposited or precipitated.

Ceramics↗