Selective detection of a catecholamine against electroactive interferents using an interdigitated heteroarray electrode consisting of a metal oxide electrode and a metal band electrode.

We developed an interdigitated array electrode (IDAE) consisting of a metal oxide electrode and a metal band heteroelectrode and employed it for the selective detection of catecholamines. We used an indium-tin oxide (ITO) film as the oxidation electrode of the IDAE because the ITO was able to suppress response currents from L-ascorbic acid (AA) and uric acid (UA), which are major electroactive interferents in biological fluids. However, the ITO film also suppresses the reduction of quinones including oxidized catecholamines. We developed a simple technique for fabricating our hetero IDAE, which also preserves the electrochemical properties of the ITO. When we compared hetero ITO-gold, homo ITO-ITO, and carbon-carbon IDAEs, we found that the hetero IDAE provided both high sensitivity and selectivity for DA detection. We achieved high selectivities for DA against AA and UA. The ratios of the response currents of AA and UA to DA were calculated as 6 and 5%, respectively.

Catecholamines↗

Selective detection of L-glutamate using a microfluidic device integrated with an enzyme-modified pre-reactor and an electrochemical detector.

A microfluidic device integrated with a nanoliter volume enzyme pre-reactor and an enzyme-modified electrode was developed for the highly selective continuous measurement of glutamate (Glu). The device consists mainly of two glass plates. One plate incorporates an electrochemical cell that consists of working electrode (WE), reference electrode (RE) and counter electrode (CE). The WE is modified with a bilayer film of Os-polyvinylpyrridine-based mediator containing horseradish peroxidase (Os-gel-HRP). The WE was operated at -50 mV versus Ag. The other plate has a thin layer flow channel integrated with a pre-reactor. The reactor has a number of micropillars (20 microm in diameter, 20 microm high and separated from each other by a 20 microm gap) modified with ascorbate oxidase (AAOx) to eliminate L-ascorbic acid (AA). The enzymatic oxidation of AA is superior to that obtained with our previously reported pre-electrolysis type micro-reactor since electrochemically reversible transmitters such as catecholamines do not provide a cathodic current at the WE. In addition, the high operation potential of the pre-reactor causes unknown electroactive species, which also cause interference at the detection electrode. As a result, we were able to detect 1 microM Glu continuously at a low flow rate even when AA concentration was 100 microM.

Ascorbic Acid↗

Separate detection of BTX mixture gas by a microfluidic device using a function of nanosized pores of mesoporous silica adsorbent.

We achieved separate detection of the components of 10 ppm of a benzene, toluene, and o-xylene mixture gas by using mesoporous silica powder incorporated in our microfluidic device. The device consists of concentration and detection cells formed of 3 cm x 1 cm Pyrex plates. We first introduced the mixture gas into the concentration cell where it was adsorbed on an adsorbent in a channel formed in the cell. We then raised the temperature using a thin-film heater and introduced the desorbed gas into the detection cell. Here, we measured the changes in the absorption spectra of the mixture gas in the detection cell. We found that the mixture ratio of the compounds in the desorbed gas varies with time because the thermal desorption property of each compound is different from that of the adsorbent. We analyzed the thermal desorption mechanism by comparing two types of silica adsorbents with different pore structures. We found that an adsorbent that has pores with a periodic and uniform nanosized column shape provides better component separation. We concluded that the uniform pore structure might cause the adsorbate molecules to exhibit a homogeneous adsorption state thus revealing the desorption properties of the gas more clearly.

Adsorption↗

Air-cooled cold trap channel integrated in a microfluidic device for monitoring airborne BTEX with an improved detection limit.

We integrated an air-cooled cold trap (CT) channel in a microfluidic device for monitoring airborne benzene, toluene, ethylbenzene, and xylene (BTEX) gases and demonstrated its effect on improving the detection limit of the microfluidic device. The device consists of concentration and detection cells formed of 3 x 1 cm Pyrex plates. We first introduced a sample gas into the concentration cell, and the gas was adsorbed onto an adsorbent in the channel. We then raised the temperature using a thin-film heater and introduced the desorbed gas into the detection cell. To prevent dilution of the gas before detection, we propose an improvement to the concentration cell structure that involves the integration of the CT channel. We examined the CT effect by comparing three types of concentration cell with different channel structures. We found that we could detect a gas concentration about 2 orders of magnitude lower than in our previous work by optimizing the channel structure and integrating a CT channel. As an example of BTEX detection,we obtained a 0.05 ppm detection limit for toluene gas with a sampling time of 30 min.

Adsorption↗

Differential measurement with a microfluidic device for the highly selective continuous measurement of histamine released from rat basophilic leukemia cells (RBL-2H3).

We fabricated a micro-fluidic device for the highly selective detection of the histamine released from rat basophilic leukemia (RBL) 2H3 cells. The device has two thin layer flow channels, each with one working electrode. One electrode was modified with Os-polyvinylpyridine based mediator containing horseradish peroxidase (Os-gel-HRP) and histamine oxidase (HAOx), the other was modified with Os-gel-HRP without any HAOx. We employed the device for differential measurement by using the HAOx modified electrode for detection and the unmodified electrode as a reference. The detection limit was greatly improved from 190 to 25 nM since the baseline noise level was suppressed. We used differential measurement to observe the histamine released from RBL-2H3 cells when stimulated with dinitrophenylated bovine serum albumin (DNP-BSA) as an antigen. We injected 5 microM of histamine solution into our device and it remained stable for more than 8 h.

Animals↗

Imaging of electrochemical enzyme sensor on gold electrode using surface plasmon resonance.

Three types of imaging, namely layer structure, electrochemical reaction, and enzyme sensor response, were achieved by applying surface plasmon resonance (SPR) measurement to an electrochemical biosensor. We constructed glucose oxidase based mediator type sensors on a gold electrode by spotting the mediator that contained horseradish peroxidase and spin coating the glucose oxidase film. The layer structure of the sensor was imaged by means of angle scanning SPR measurement. The single sensor spot (about 1 mm in diameter) consisted of about 100 x 100 pixels and its spatial structure was imaged. The multilayer structure of the enzyme sensor had a complex reflectance-incident angle curve and this required us to choose a suitable incident angle for mapping the redox state. We chose an incident angle that provided the most significant reflection intensity difference by using data obtained from two angle scanning SPR measurements at different electrode potentials. At this incident angle, we controlled the electrochemical states of the spotted mediator in cyclic voltammetry and imaged the degree to which the charged site density changed. Finally, we mapped the enzymatic activity around the mediator spot by the enzymatic reoxidation of pre-reduced mediator in the presence of glucose.