Control of microbial activity by flow injection analysis during high cell density cultivation of Escherichia coli.

The application of an automated flow injection analysis (FIA) system for on-line determination of microbial activity, during high cell density cultivations of Escherichia coli is reported. Based on a bioelectrochemical principle, the FIA method used a redox mediator (potassium hexacyanoferrate(III)) to facilitate electron transfer from the microorganisms to an electrochemical detector. Assays were carried out using a new sampling device which provided aseptic operation by use of a valve and chemical sterilisation. No sample dilution or pretreatment was necessary for biomass concentrations up to approx. 40 g l-1. The sample volume was 0.5 ml and the overall analysis time was 5 min. FIA signals were found to correlate well with the oxygen uptake rate (OUR). Changes in metabolic activity due to low substrate levels or high inhibitor concentrations in the cultivation medium became obvious from the FIA signals.

Bacteriological Techniques↗

On-line determination of glucose concentration throughout animal cell cultures based on chemiluminescent detection of hydrogen peroxide coupled with flow-injection analysis.

A flow-injection analysis (FIA) system for the on-line determination of glucose in animal cell cultures is described. The system is based on immobilized glucose oxidase (GOD). The hydrogen peroxide generated in the enzyme reaction is determined via a highly sensitive chemiluminescent reaction with luminol. Based on the measurement of the maximum emitted light intensity, the system was able to analyse hydrogen peroxide over the concentration range of 10(-7) to 10(-2) M. For glucose determination, the system has a linear range of 10(-5) to 5 x 10(-2) M glucose, with an r.s.d. of 3% at the 1 mM level (5 measurements). The influence of luminol and buffer concentrations, pH and temperature on the chemiluminescent reaction were investigated. The enzyme reactor used was stable for more than 4 weeks in continuous operation, and it was possible to analyse up to 20 samples per h. The system has been successfully applied to on-line monitoring of glucose concentration during an animal cell culture, designed for the production of human antithrombin III factor. Results obtained with the FIA system were compared with off-line results, obtained with a Yellow Springs Instrument Company Model 27 (YSI).

Animals↗