A completely automated CAD system for mass detection in a large mammographic database.

Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.

Algorithms↗

Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy.

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detector allowed its use with a larger pinhole collimator than could be used with the CZT detector. Additionally, the improved pinhole collimator and alignment features of the apparatus permitted much more rapid setup for acquisition of x-ray spectra than was possible on the system described in the earlier work. These improvements in detector technology, collimation and ease of alignment, as well as low cost, make this apparatus attractive as a tool for both laboratory research and advanced mammography quality control.

Calibration↗

GPCALMA: a Grid-based tool for mammographic screening.

OBJECTIVES: The next generation of high energy physics (HEP) experiments requires a GRID approach to a distributed computing system: the key concept is the Virtual ORGANISATION (VO), a group of distributed users with a common goal and the will to share their resources. METHODS: A similar approach, applied to a group of hospitals that joined the GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography), will allow common screening programs for early diagnosis of breast and, in the future, lung cancer. The application code makes use of neural networks for the image analysis and is useful in improving the radiologists' diagnostic performance. GRID services allow remote image analysis and interactive online diagnosis, with a potential for a relevant reduction of the delays presently associated with screening programs. RESULTS AND CONCLUSIONS: A prototype of the system, based on AliEn GRID Services [1], is already available, with a central server running common services [2] and several clients connecting to it. Mammograms can be acquired in any location; the related information required to select and access them at any time is stored in a common service called Data Catalogue, which can be queried by any client. Thanks to the PROOF facility [3], the result of a query can be used as input for analysis algorithms, which are executed on the nodes where the input images are stored,. The selected approach avoids data transfers for all the images with a negative diagnosis and allows an almost real time diagnosis for the set of images with high cancer probability.

Algorithms↗

Direct analysis of molybdenum target generated x-ray spectra with a portable device.

In routine applications, information about the photon flux of x-ray tubes is obtained from exposure measurements and cataloged spectra. This approach relies mainly on the assumption that the real spectrum is correctly approximated by the cataloged one, once the main characteristics of the tube such as voltage, target material, anode angle, and filters are taken account of. In practice, all this information is not always available. Moreover, x-ray tubes with the same characteristics may have different spectra. We describe an apparatus that should be useful for quality control in hospitals and for characterizing new radiographic systems. The apparatus analyzes the spectrum generated by an x-ray mammographic unit. It is based on a commercial CZT produced by AMPTEK Inc. and a set of tungsten collimator disks. The electronics of the CZT are modified so as to obtain a faster response. The signal is digitized using an analog to digital converter with a sampling frequency of up to 20 MHz. The whole signal produced by the x-ray tube is acquired and analyzed off-line in order to accurately recognize pile-up events and reconstruct the emitted spectrum. The energy resolution has been determined using a calibrated x-ray source. Spectra were validated by comparison of the HVL measured using an ionization chamber.

Algorithms↗

[Application of a computer-aided detection (CAD) system to digitalized mammograms for identifying microcalcifications].

PURPOSE: It is estimated that during mammographic screening programs radiologists fail to detect approximately 25% of breast cancers visible on retrospective review; this percentage rises to 50% if minimal signs are considered. Independent double reading is now strongly recommended as it allows to reduce the rate of false negative examinations by 5-15%. Recent technological progress has allowed to develop a number of computer-aided detection (CAD) systems. The aim of CAD is to help radiologists interpret lesions by serving as a second reader. In this study the authors developed and applied a CAD system to measure its ability to microcalcifications detect and compare its performance with that of a human observer. MATERIAL AND METHODS: The study was performed as part of the CALMA (computer-aided library for mammography) project of the Pisa section of the National Institute of Nuclear Physics. The aim of this project is to set up a large database of digital mammograms and to develop a CAD system. Our study series consisted of 802 mammograms - corresponding to 213 patients - digitalized between March and June 2000. We performed traditional mammography and then digitalized the mammograms using a CCD linear scanner (pixel size of 85 x 85 microm2, 12 bits). The images were evaluated by two radiologists with similar experience and then by the CAD system. This CAD system searches for microcalcifications by using ad hoc algorithms and an artificial neural network (Sanger type). RESULTS: The number of clusters in our database was 141 corresponding to 140 images; 692 images were non pathological. The CAD system identified a variable number of clusters depending on the threshold values. The threshold value is a number over which the probability of finding a lesion is highest. With thresholds of 0.13 and 0.14 the CAD system identified 140/141 clusters (99.3%); with a threshold of 0.15 it identified 139/141 clusters (98.6%); with a threshold of 0.16, 137/141 (97.2%); with a threshold of 0.18, 133/141 (94.3%); with thresholds of 0.18 and 0.20, 130/141 (92.2%). With threshold values of 0.13, 0.14, 0.15, 0.16 and 0.17 the system's sensitivity was greater than 82%, whereas with values of 0.18 and 0.20 it was greater than 80%. The number of false positive region of interest (ROI) / image was greater with low threshold values: in particular, thresholds of 0.13 and 0.14 yielded 16 false positives /image, thresholds of 0.15 and 0.16 yielded 9 and 7 false positives/image, and both 0.18 and 0.20 only 5/image. DISCUSSION: ROC curve shows how the use of high threshold values determined a very high specificity despite very low sensitivity rates. Conversely, low threshold values allowed to have a high sensitivity and a very low specificity. The best performance of our CAD system was obtained with threshold values at 0.15 and 0.16. In fact these thresholds resulted in a high sensitivity (greater than 82%) with an acceptable number of false positives/image, 9 and 7/image, respectively. It is not yet known how radiologists can deal with large numbers of false positives in screening programmes but in our opinion the most important feature of a good CAD system is a high sensitivity. CONCLUSIONS: In the near future the use of CAD systems will be widespread and easier to apply to everyday practice above all in centers where digital mammography is performed. Mammograms could be directly shown to radiologists after the CAD system has selected the ROI and analysed the images. Thanks to its high sensitivity and despite its low specificity CAD represents a concrete aid for radiologists.

Breast Diseases↗

Correlation between hydroperoxide-induced chemiluminescence of the heart and its function.

The isolated perfused rat heart emits a spontaneous ultraweak chemiluminescence. When the perfusion is stopped, light emission decreases, indicating the dependency of this phenomenon on aerobic metabolism. Emitted chemiluminescence was markedly enhanced following perfusion with 0.05 mM H2O2 or cumene hydroperoxide or tert-butyl hydroperoxide; substitution of O2 for N2 in the gassing mixture of the perfusion media significantly lowered photon emission. Lipid peroxidation, which is known to be associated with chemiluminescence, was evaluated by HPLC analysis of peroxidized and unperoxidized heart phosphatidylcholines. During hydroperoxide perfusion, coronary flow and heart rate progressively decreased, while lactic dehydrogenase was released after complete cardiac arrest. The resultant morphology of this damage corresponds to the so-called 'stone heart', a pattern already described in both human and experimental pathology.

Animals↗