PubMed HealthSearch

Biomedical subjects

U Can

Publications and source records attributed to U Can.

7 recordsLinked to original sources

Transcranial Doppler ultrasound criteria for hemodynamically significant internal carotid artery stenosis based on residual lumen diameter calculated from en bloc endarterectomy specimens.

BACKGROUND AND PURPOSE: Transcranial Doppler (TCD) is often used in conjunction with carotid duplex ultrasonography (CDUS) to evaluate the hemodynamic significance of internal carotid artery (ICA) stenosis. We examined the sensitivity and specificity of TCD criteria for detection of a hemodynamically significant stenosis (residual lumen diameter < 1.5 mm) at the origin of the ICA. METHODS: We selected patients who underwent carotid end-arterectomy (CEA) and had preoperative TCD data available. Eighty-one patients underwent transorbital evaluation, 49 of whom also had transtemporal TCD performed. The endarterectomy specimens were removed en bloc and sectioned, and the minimal residual lumen diameter calculated by computer analysis. RESULTS: For the transorbital approach, the strongest indicators of a residual lumen diameter < 1.5 mm were reversed flow in the ipsilateral ophthalmic artery and a > 50% peak systolic velocity difference between the carotid siphons (distal ICAs) in patients with unilateral ICA origin stenosis. They were 100% specific and 31% and 26% sensitive, respectively. For the transtemporal approach in patients with a unilateral stenosis, a > 35% difference in ipsilateral middle cerebral artery (MCA) peak systolic velocity relative to the contralateral MCA or a > 50% difference in contralateral anterior cerebral artery (ACA) peak systolic velocity relative to the ipsilateral ACA were 100% specific for identifying a residual lumen diameter of < 1.5 mm. Sensitivities were 32% and 43%, respectively. Irrespective of contralateral stenosis, a > 35% difference in ipsilateral MCA peak systolic velocity relative to the ipsilateral posterior cerebral artery had a 100% specificity and a 23% sensitivity for detecting a < 1.5 mm minimal residual lumen diameter. CONCLUSIONS: Although the TCD sensitivity for detecting a hemodynamically significant stenosis is relatively low, it can be highly specific (up to 100%). We conclude that TCD enhances the specificity of highly sensitive CDUS criteria for detecting a hemodynamically significant ICA stenosis.

Aged

Hyperacute stroke: evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging.

PURPOSE: To evaluate acute stroke with conventional, multisection diffusion-weighted (DW), and hemodynamically weighted (HW) magnetic resonance (MR) imaging. MATERIALS AND METHODS: The three MR imaging techniques were performed in 11 patients within 10 hours of the onset of acute hemiparesis. The volume of DW and HW abnormalities were compared with infarct volumes depicted at initial and/or follow-up MR or computed tomography (CT). RESULTS: Findings at DW and HW imaging were abnormal in nine of the 11 patients, despite normal findings at initial CT and/or MR. In all nine patients, infarcts were depicted at follow-up CT or MR. The DW abnormality was generally smaller and the HW abnormality was generally larger than the infarct volume determined at subsequent imaging. In the two patients with normal findings at DW and HW imaging, symptoms resolved completely within 1-48 hours. CONCLUSION: Different aspects of hyperacute cerebral ischemia are depicted at DW and HW imaging before infarction is depicted at conventional MR or CT. These techniques may improve stroke diagnosis and may contribute to advances in treatment.

Acute Disease

Carotid Doppler ultrasound criteria for internal carotid artery stenosis based on residual lumen diameter calculated from en bloc carotid endarterectomy specimens.

BACKGROUND AND PURPOSE: Carotid duplex ultrasound is widely used to screen patients for carotid endarterectomy and if combined with MR angiography and transcranial Doppler may be an alternative to conventional angiography in the preoperative assessment. We have examined the correlation between Doppler velocities and the residual lumen diameters of internal carotid arteries from surgical pathological specimens to establish Doppler criteria for residual lumen diameter independent of percent stenosis. METHODS: Ninety-one patients who underwent 99 carotid endarterectomies for internal carotid artery stenosis within 6 months of their carotid duplex ultrasound evaluation were studied. The endarterectomy specimens were removed en bloc, and the minimal residual lumen diameter was calculated by computer analysis. The sensitivity and specificity of the Doppler criteria for determining high-grade stenosis were calculated and receiver-operator curves generated. RESULTS: Peak systolic velocity (PSV), end-diastolic velocity (EDV),and carotid index (peak internal carotid artery velocity/ common carotid artery velocity) correlated with the residual lumen diameter. PSV > 440 cm/s, EDV > 155 cm/s, or carotid index > 10 indicated a residual lumen diameter of < or = 1.5 mm (specificity of 100% and sensitivity of 58%, 63%, and 30%, respectively). When these criteria were combined, the sensitivity increased to 72%. A PSV > 200 cm/s combined with either an EDV > 140 cm/s or a carotid index > 4.5 has a sensitivity of 96% and a specificity of 61%. CONCLUSIONS: Doppler criteria can be both specific and sensitive for detecting a significant stenosis, defined as a < or = 1.5 mm residual lumen diameter. By adjustment of the velocity criteria, it can be 100% specific or a highly sensitive test (96%).

Blood Flow Velocity