PubMed Health⌕ Search

Biomedical subjects

U Danielsson

Publications and source records attributed to U Danielsson.

7 recordsLinked to original sources

Windchill and the risk of tissue freezing.

Low air temperatures and high wind speeds are associated with an increased risk of freezing of the exposed skin. P. A. Siple and C. F. Passel (Proc. Am. Phil. Soc. 89: 177-199, 1945) derived their windchill index from cooling experiments on a water-filled cylinder to quantify the risk of frostbite. Their results are reexamined here. It is found that their windchill index does not correctly describe the convective heat transfer coefficient (hc) for such a cylinder, the effect of the airspeed (v) is underestimated. New risk curves have been developed, based on the convection equations valid for cylinders in a cross flow, hc infinity v0.62, and tissue freezing data from the literature. An analysis of the data reveals a linear relationship between the frequency of finger frostbite and the surface temperature. This relation closely follows a normal distribution of finger-freezing temperatures, with an SD of 1 degree C. As the skin surface temperature falls from -4.8 to -7.8 degrees C, the risk of frostbite increases from 5 to 95%. These data indicate that the risk of finger frostbite is minor above an air temperature of -10 degrees C, irrespective of v, but below -25 degrees C there is a pronounced risk, even at low v.

Body Temperature↗

Convective heat transfer measured directly with a heat flux sensor.

A heat flux disk has been developed that directly measures the convective heat transfer in W/m2. When the sensor is calibrated on an aluminum cylinder, the calibration constant obtained is greatest in still air. As air movement increases, the calibration constant is reduced with increasing convective heat transfer coefficient, 0.5%.W-1.m2.K. The influence of wind on the calibration value is greatly reduced when the sensor is attached to a surface with lower thermal conductivity. The local convective heat transfer coefficient (hc) of the human body was measured. The leg acts in a manner similar to that of a cylinder, with the highest hc value at the front facing the wind and the lowest approximately 90 degrees from the wind, and in the wake a value is obtained that is close to the average hc value of the leg. When hc is measured at several angles and positions all over the body, the results indicate that the body acts approximately as a cylinder with a hc value related to the wind speed as hc = 8.6.v0.6 W.m-2.K-1, where v is velocity.

Biophysical Phenomena↗