PubMed Health⌕ Search

Biomedical subjects

U Holzwarth

Publications and source records attributed to U Holzwarth.

21 records · Page 2Linked to original sources

A modular femoral implant for uncemented stem revision in THR.

We present the early results of 142 uncemented femoral stem revisions using the modular MRP-Titan system. There were 70 cases with marked preoperative femoral bone defects (Paprosky type 2C and type 3); and bone grafts were used in 31 cases. At a mean follow-up of 2.3 years five cases were re-revised due to dislocation and two due to aseptic loosening. The mean Harris hip score improved from 37.4 preoperatively to 92.4. In 122 cases progressive bone regeneration on X-ray was seen; and no further osteolysis was observed.

Adult↗

The Morse taper junction in modular revision hip replacement--a biomechanical and retrieval analysis.

All biomaterials used for total joint surgery are subjected to wear mechanisms. Morse taper junctions of modular hip revision implants are predilection sites for both fretting and crevice corrosion, dissociation and breakage of the components. The aim of this study is to quantify wear and study metallurgical changes of Morse taper junctions of in-vitro and in-vivo loaded modular revision stems. Three modular revision stems (MRP-Titan, Peter Brehm GmbH, Germany) were loaded by a servohydraulic testing machine. The loads and conditions used exceeded by far the values required by ISO-standard 7206. The tests were performed with maximum axial loads of 3,500 N to 4,000 N over 10-12 x 10(6) cycles at 2 Hz. Additionally, the female part of the taper junctions were coated with blood and bone debris. The free length of the implant was set to 200 mm. One other MRP stem was investigated after retrieval following 5.5 years of in-vivo use. All contact surfaces of the modular elements were assessed by visual inspection, optical microscopy and scanning electron microscopy (SEM). The degree of plastic deformation of the male part of the morse taper junction was determined by contouroscopy. None of the morse taper junctions broke or failed mechanically. Corrosion and wear affected all tapers, especially at the medial side. The retrieved implant showed no cracks and the amount of debris measured only one third of that for the stems tested in-vitro. The present retrieval and laboratory investigations have proven, that the morse taper junctions of the MRP-titanium stem are stable and resistant to relevant wear mechanisms. The longevity of the junctions for clinical use is given. If an optimal taper design is selected, the advantages of modular femoral components in total hip revision arthroplasty will outweigh the possible risks.

Biomechanical Phenomena↗

[Results of uncemented revision arthroplasty of the hip with the MRP-stem using an intrafemoral approach with vascularized distal fenestration].

AIM: THR is one of the most successful principles in orthopaedics. With the increasing number of primary THR more and more revision arthroplasties of the hip are necessary. Many factors including loss of bone stock, instability of the joint, infection, fractures, removal of the implant or cement mantles are a challenging condition for the surgeon. Many approaches and techniques for the removal of cement mantles are published. We prefer the intrafemoral approach with an distal vascularized femoral window. METHOD: We want to describe our surgical technique and report the short term results of 45 revision arthroplasties of the hip using the uncemented modular titanium MRP stem. Mean follow-up was 2.6 years (min:1 year, max: 7 years). RESULTS: Mean Harris hip score increased from preoperative 53,2 (16 - 89) to postoperative 90.4 (35 - 100) points. We could find remodelling of the bone and spontaneous refill of bony defects in all cases. After 14 weeks we could find bony consolidation of the femoral window. The Trendelenburg sign was positive preoperatively in 26 cases, postoperatively in 11 cases. Just one single dislocation of the revised hip occurred postoperatively. CONCLUSION: The intrafemoral approach with distal vascularized femoral fenestration is a mild approach without further weakening of the pelvitrochanteric muscles. Removal of cement mantles is possible without any problems. Using the vascularized technique of the femoral fenestration prompt bony consolidation can be achieved.

Arthroplasty, Replacement, Hip↗