Pulmonary embolism: comprehensive diagnosis by using electron-beam CT for detection of emboli and assessment of pulmonary blood flow.

PURPOSE: To comprehensively assess thoracic anatomy and pulmonary microcirculation in pulmonary embolism by using computed tomographic (CT) angiography of the pulmonary arteries combined with functional CT imaging of blood flow. MATERIALS AND METHODS: Twenty-two patients suspected of having acute pulmonary embolism underwent contrast material-enhanced thin-section electron-beam CT angiography of the pulmonary arteries. In addition, in each patient, a dynamic multisection blood flow CT study was performed on a 7.6-cm lung volume with electrocardiographic gating. Pulmonary blood flow was calculated, and perfusion parameters were visualized on color-coded maps. The color-coded maps and CT angiograms were independently evaluated, segment by segment, by two readers for perfusion deficits and the presence of clots, respectively. The results were compared. RESULTS: Mean pulmonary blood flow was 0.63 mL/min/mL in the occluded segments versus 2.27 mL/min/mL in the nonoccluded segments (P: =.001). The sensitivity and specificity of perfusion maps for the presence of segmental pulmonary embolism compared with those of CT angiography were 75.4% and 82.3%, respectively, with positive and negative predictive values of 79.6% and 84.7%, respectively. The false-negative findings were caused mainly by partial occlusion of vessels. In eight patients, a substantial alternative or additional pathologic entity was diagnosed. CONCLUSION: By combining CT angiography and dynamic CT imaging, a comprehensive and noninvasive diagnosis of thoracic structure and function is feasible with a single modality.

Acute Disease↗

Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification.

OBJECTIVE: We compared electron beam CT with conventional CT to determine the best method for the assessment of the coronary calcium score. We used conventional CT to examine symptomatic and asymptomatic patients suspected of having coronary artery disease. SUBJECTS AND METHODS: One hundred sixty male patients underwent electron beam CT and helical CT with a pitch of 1 (n = 30) and 2 (n = 30) and using a single-slice mode with (n = 50) and without (n = 50) prospective ECG triggering. In another 50 patients, we determined reproducibility for repeated scanning using electron beam CT. For all images, we derived the calcium score according to the Agatston method. We performed regression analysis and determined mean variability. Mean variability was calculated as the ratio of the absolute difference to the mean of the corresponding calcium scores. RESULTS: The correlation coefficients for electron beam CT and all conventional CT modes were very high (range, 0.93-0.98). The mean variability was highest in the helical mode with a pitch of 2 (61.4%) and lowest for the single-slice mode with prospective ECG triggering (25.4%). For repeated electron beam CT, the correlation coefficient and mean variability were 0.99 and 22.1%, respectively. CONCLUSION: ECG-triggered single-slice conventional CT had the best agreement with electron beam CT calcium scores.

Calcinosis↗

[Computed tomography of the abdomen with multidetector-array CT].

BACKGROUND: The advent of multidetector CT (MDCT) constitutes a quantum leap creating a wealth of new opportunities in medical imaging. However, while the basic principles of spiral CT still apply, we are now challenged to rethink our strategies in planning a CT study to take full advantage of the increased capabilities of MDCT. MATERIALS AND METHODS: We report here our preliminary experiences with MDCT for abdominal CT imaging within a 5-month period. During this time, suitable protocols for investigation of the abdomen using MDCT were developed. The capabilities of MDCT allow for tailoring dedicated CT protocols for routine applications as well as for biphasic liver studies and CT angiography of the aorta and abdominal vessels. RESULTS: The speed of MDCT can either be used to reduce the time needed to cover a given volume, or to use narrower beam collimations to increase the resolution of detail along the z-axis and reduce volume averaging. Higher scan speed allows reduction of the amount of contrast material in vascular applications and suppression of motion artifacts. Higher spatial resolution with thinner collimations reduces volume averaging and improves the detection of small hepatic and pancreatic lesions. Detailed analysis of vascular structures and high-quality three-dimensional reformations become feasible. New problems arise from the large amount of data generated by MDCT. CONCLUSIONS: MDCT offers a wealth of new opportunities that help us to come to a fast and accurate diagnosis in suspected abdominal disease. Traditional indications for performing CT are reemphasized and new clinical applications can be exploited.

Abdomen↗

[Imaging of the thorax with multislice spiral CT].

With multislice spiral computed tomography (MSCT), existing indications for performing CT of the chest are strengthened and new applications are emerging. The high speed of MSCT improves efficiency, image quality and patient comfort of "routine" imaging of the chest. The ability to cover large volumes with thin slices improves the evaluation of mediastinal lymph nodes and pulmonary nodules and allows for high-quality secondary reconstruction. If a comprehensive diagnosis of the mediastinal structures and the pulmonary parenchyma is desired, MSCT for the first time allows reconstruction of contiguous and high-resolution (HRCT) sections from the same set of thin-collimation raw data. This way, contiguous chest images of superior and HRCT sections of equal image quality compared to conventional CT scanning can be obtained. Vascular protocols greatly benefit from the high speed of MSCT: For imaging the thoracic aorta or pulmonary emboli (PE), the amount of contrast material can be substantially reduced. Owing to thin collimation, the detection rate of small peripheral emboli can be significantly increased. If indicated, the entire subphrenic venous system can be evaluated during the same session, without additional contrast material.

Adult↗

Detection and quantification of coronary artery calcification with electron-beam and conventional CT.

To identify patients with increased risk of having coronary artery disease (CAD), electron-beam computed tomography (EBCT) was used for years for quantifying calcifications of the coronary arteries. The first direct comparison between EBCT and conventional CT was performed to determine the reliability of widely available conventional CT for the assessment of the coronary calcium score. Fifty male patients with suspected CAD were investigated with both modalities, EBCT and conventional 500-ms non-spiral partial scan CT. Scoring of the coronary calcification was performed according to the Agatston method. Forty-two of these patients underwent coronary angiography for the assessment of significant luminal narrowing. The correlation coefficient of the score values of both modalities was highly significant (r = 0.982, p < 0.001). The variability between the two modalities was 42%. Mean calcium score in patients with significant coronary luminal narrowing (n = 37) was 1104 +/- 1089 with EBCT and 1229 +/- 1327 with conventional CT. In patients without luminal narrowing (n = 5) mean calcium score was 73 +/- 57 with EBCT and 26 +/- 35 with conventional CT. Although images of the heart from conventional CT may suffer from cardiac motion artifacts, conventional CT has the potential to identify patients with CAD with accuracy similar to EBCT.

Artifacts↗

Electrocardiographically gated thin-section CT of the lung.

PURPOSE: To determine whether electrocardiographic (ECG) gating improves image quality of thin-section computed tomographic (CT) scans of the lung obtained with a subsecond CT scanner. MATERIALS AND METHODS: Thin-section CT was performed in 35 patients by using standard techniques. Three additional sections were obtained in each patient with prospective ECG gating at corresponding levels of the paracardiac lung parenchyma. Non-ECG-gated and ECG-gated sections were then rated in blinded fashion by three experienced radiologists for overall image quality, spatial resolution, and diagnostic value and for different types of respiratory and cardiac motion artifacts. RESULTS: ECG gating helped significantly reduce artifacts caused by cardiac motion (i.e., distortion of pulmonary vessels, double images, or blurring of the cardiac border) (P < .05). ECG gating did not reduce respiratory motion artifacts. In patients with heart rates of less than 76 beats per minute, ECG gating significantly improved overall image quality (P = .041). ECG gating was not perceived to increase the diagnostic value of thin-section CT scans. CONCLUSION: ECG gating improves image quality of thin-section CT scans of the lung by reducing cardiac motion artifacts that may mimic disease. It must be established whether ECG gating can help increase the diagnostic accuracy of thin-section CT for the evaluation of subtle parenchymal disease.

Adult↗

[Computer-assisted diagnosis based on computer-based image interpretation and 3D-visualization].

PURPOSE: To survey methods for 3D data visualization and image analysis which can be used for computer based diagnostics. MATERIAL AND METHODS: The methods available are explained in short terms and links to the literature are presented. Methods which allow basic manipulation of 3D data are windowing, rotation and clipping. More complex methods for visualization of 3D data are multiplanar reformation, volume projections (MIP, semi-transparent projections) and surface projections. Methods for image analysis comprise local data transformation (e.g. filtering) and definition and application of complex models (e.g. deformable models). RESULTS: Volume projections produce an impression of the 3D data set without reducing the data amount. This supports the interpretation of the 3D data set and saves time in comparison to any investigation which requires examination of all slice images. More advanced techniques for visualization, e.g. surface projections and hybrid rendering visualize anatomical information to a very detailed extent, but both techniques require the segmentation of the structures of interest. Image analysis methods can be used to extract these structures (e.g. an organ) from the image data. DISCUSSION: At the present time volume projections are robust and fast enough to be used routinely. Surface projections can be used to visualize complex and presegmented anatomical features.

Diagnosis, Computer-Assisted↗

[Virtual and three-dimensional bronchoscopy with spiral and electron beam computed tomography].

PURPOSE: To compare spiral computed tomography (CT) and electron-beam CT (EBT) for 3D and virtual CT-bronchoscopy. MATERIALS AND METHODS: 17 patients with various disorders of the tracheobronchial system were examined using fiberoptic bronchoscopy, spiral CT and EBT. 3D images were reconstructed from CT data sets using automated segmentation based on volume-growing methods. Surface-rendered, volume-rendered, and hybrid reconstructions were visualized in real time using a data helmet. RESULTS: All data sets could be processed to high-quality three-dimensional (3D) and virtual reconstructions. The reduction of motion artifacts due to shorter scan times made EBT data sets better suited for automated segmentation and less susceptible to motion artifacts. 3D and virtual reconstructions did not increase the diagnostic sensitivity of CT compared to axial reconstructions alone. CONCLUSIONS: Shorter scan times of CT imaging yield higher-quality 3D and virtual reconstructions. Modern reconstruction techniques are valuable visualization tools for select indications and are the prerequisite for future developments in computer-aided medicine.

Bronchial Neoplasms↗

[Technical bases and acquisition conditions of electron-beam computed tomography].

PURPOSE: In this review the technical principle and scanner characteristics of electron beam computer tomography (EBCT) are discussed. METHODS: In contrast to conventional CT, image acquisition in EBCT is achieved without mechanically moving parts. This construction allows for short acquisition times in investigating given anatomical regions (100 ms per slice) or up to 8 levels without table movement and short interscan delays (50 ms per slice). RESULTS: Depending on the nature of the investigation, the scanner can be used in the single slice, continuous volume scanning and multi slice mode. The single slice mode is used for detection and quantification of coronary calcifications and for CT angiography of the coronary vessels. Equivalent to the spiral mode in conventional CT, continuous volume scanning may be used for routine investigation of the chest and abdomen. Functional investigations of the heart and perfusion measurement of different organs can be performed in multi slice mode. Because of the geometry of the electron beam scanner, radiation exposure for certain investigations is above the exposure with conventional CT. CONCLUSION: Future developments will focus on dose efficient radiation collimation, high resolution detector systems and artefact reducing reconstruction kernels.

Algorithms↗

[Methods of quantification of coronary artery calcifications with electron-beam and conventional computed tomography].

PURPOSE: To compare electron beam CT (EBCT) und prospectively ECG gated conventional CT for the detection and quantification of coronary artery calcifications. METHODS: 42 patients (mean age 62.8 +/- 8.8 years) were scanned, both with EBCT and ECG gated sequential CT. For quantification, the traditional "total calcium score" (TCS) according to the Agatson method as well as the "volumetric calcium score" (VCS) as determined with a stand-alone workstation (NetraMD) was calculated for both modalities. RESULTS: There was close correlation between EBCT and conventional CT, both for TCS (r = 0.984) as well as for VCS (r = 0.986) score values. The median difference was 17% for TCS and 13% for VCS. The difference between the two modalities was not statistically significant (p = 0.44). CONCLUSION: EBCT and prospectively ECG triggered conventional CT are equivalent for the quantification of coronary artery calcifications. The extent of calcifications can be established with both modalities using either TCS or VCS score values.

Age Factors↗

[Diagnosis of pulmonary embolism with spiral and electron-beam CT].

PURPOSE: To compare spiral (SCT) and electron-beam CT (EBT) for the diagnosis of pulmonary embolism (PE). MATERIALS AND METHODS: From June 1997 to June 1998 188 patients with suspected acute or chronic thromboembolism of the pulmonary arteries were examined. A total of 108 patients were scanned using SCT and 80 patients using EBT. On each scanner two different scan protocols were evaluated. RESULTS: PE was diagnosed in 38 patients using EBT and in 49 patients using SCT. Especially with EBT, isolated peripheral emboli could be confidently diagnosed. When EBT and SCT were compared for the analysis of peripheral pulmonary arteries, some paracardiac segmental and subsegmental vessels were significantly better analyzable with EB. Additional or diseases other than PE were diagnosed in 112 patients. Other diagnoses included bronchial carcinoma and aortic dissection. CONCLUSIONS: Advanced CT scanning techniques allow the highly accurate diagnosis of central and peripheral PE. Other potentially life-threatening underlying diseases are also readily recognized.

Aortic Dissection↗

Xenon versus ceramics: a comparison of two CT X-ray detector systems.

PURPOSE: The purpose of this work was to compare image quality in phantom and patient CT scans acquired by xenon and ceramic CT detector systems. METHOD: High and low contrast resolution and image noise were determined with a standard CT phantom for both detector systems. In patient CT images, the effect on image noise was measured in anatomical regions of interest in the head, lumbar spine, chest, and abdomen. RESULTS: In phantom studies, image noise was significantly lower using ceramic versus xenon detectors. Also, in images of the head and lumbar spine, the signal-to-noise ratio was significantly higher with ceramic than with xenon detectors. In chest scans, ceramic significantly reduced beam-hardening artifacts caused by the thoracic spine. However, in abdominal images, the signal-to-noise ratio was not significantly different between ceramic and xenon detector systems. CONCLUSION: For reduced image noise in CT images of the head, lumbar spine, and chest and high resolution CT, ceramic detector systems appear to be superior to xenon detector systems.

Artifacts↗