PubMed Health⌕ Search

Biomedical subjects

U Morgenstern

Publications and source records attributed to U Morgenstern.

12 recordsLinked to original sources

Integration of intraoperative 3D-ultrasound in a commercial navigation system.

STUDY AIMS: The purpose of this study was the integration of three-dimensional ultrasound data into a neuronavigation system, in order to allow a guided intraoperative resection control during neurosurgical interventions. MATERIAL AND METHODS: A system for iterative neuronavigation based on 3D-ultrasound (US) has been developed. The main components of the system are the ultrasound device Voluson 730 (GE Healthcare) with a 5 - 9 MHz probe, the navigation system VectorVision2 (BrainLAB AG) and a standard PC with Windows XP. The ultrasound data are transferred via DICOM from the ultrasound device to an external computer, where they are processed with a C++ program for representation in the neuronavigation coordinate system. The data transfer between the navigation system and the external computer is performed via the VVLink interface from BrainLAB. The feasibility test of the system was performed with an ultrasound phantom RMI 403GS (Gammex-RMI GmbH). RESULTS: The error of homologous points mapping from US datasets to a CT dataset in the neuronavigation system was determined to be 1.9 +/- 0.97 mm. The maximum time required to technically integrate the ultrasound data into the navigation system was 1.5 min. CONCLUSIONS: The developed system allows 3D-ultrasound based navigation to be carried out with a commercially available navigation system. The functionality of this system has been proven by technical tests. Recording and integration of the ultrasound data can be repeated at any time during surgery and can be used to update anatomical data and consequently for resection control. Another application is the intraoperative adaptation of preoperative datasets (MRI or CT) in order to compensate for "brain shift" during neurosurgical operations.

Algorithms↗

Objective evaluation of three-dimensional image registration algorithms--tools for optimization and evaluation.

OBJECTIVE: The registration of medical volume data sets plays an important role when different images or modalities are used during computer-assisted surgical procedures. Nevertheless, it is often questionable how robust and accurate the underlying algorithms really are. Therefore, the goal is to foster the establishment of methods for an objective evaluation. METHOD: To reliably calculate the accuracy of registration algorithms, a reference transformation must be known. Due to the unknown perfect registration for real clinical data, the simulation of realistic data and successive affine transformations are employed. The simulation is based on models of the respective imaging modality where the dominant physical effects are taken into account. This gives the user full control over all simulation and transformation parameters. Finally, suitable quality measures are applied which allow a systematic evaluation of image registration accuracy by comparing the known theoretical result and the transformation calculated by the algorithm under investigation. RESULTS: During the development of a new registration algorithm, the presented method proved to be a very valuable tool for optimization and evaluation of registration accuracy, since it allows objective numerical comparison of the calculated results. CONCLUSIONS: The presented method can be used during the development of algorithms for optimization and for quantitative comparison of different registration schemes. The respective software tool can automatically generate and transform simulated but realistic data. Employing suitable numerical quality measures, an objective evaluation of registration results can be easily obtained. Still, the validity of the relatively simple models has to be verified to draw reliable conclusions with respect to real data.

Algorithms↗

[Integration of the Aasalid test in an online measurement system for evaluating cerebral autoregulation].

An important question during the intensive care of patients with subarachnoid hemorrhage and craniocerebral trauma is the evaluation of the cerebral autoregulation (CA). The so called Aaslid-Test is a standard method which allows the cerebral autoregulation to be classified. As the results under repetitive conditions show a high variation, it has not been yet possible to draw statistically proved conclusions concerning the performance of the CA. To improve the test results the measuring conditions are discussed and systematized. The algorithms of the Aaslid-Test have been implemented to an online measuring system. The error bandwidth has been estimated. To avoid systematically occurring errors an enhanced measuring protocol is provided.

Algorithms↗

[Comparison of the accuracy of 3-dimensional fusion algorithms].

Recently many algorithms for matching three-dimensional medical data have been developed. Inter- and intramodal fusion of data adds valuable information for planning, controlling and evaluating therapies. This work presents a procedure to evaluate the accuracy of fusion algorithms by numerical means. In contrast to the usual way of visual inspection the developed software tools allow automatic numerical--and thus objective--evaluation of different algorithms using simulated realistic volume data. It is therefore possible to conduct reproducible comparisons of different matching methods. These tools also proved to be very valuable during the development and optimisation of an algorithm employing normalised mutual information.

Algorithms↗

[Variability of ventilation parameters of home ventilation equipment].

The performance of pressure- and volume controlled ventilators used for invasive and non-invasive ventilation in the home were tested on a patient lung model. In order to determine the influence of tidal volume preset, breathing rate, resistance, compliance and leakage to the variability of delivered tidal volume and peak airway pressure a factorial plan with adapted analysis of variance was used. The influence of tidal volume preset, compliance and leakage to the delivered tidal volume is significant. The peak airway pressure depends hardly on the influence factors. All tested ventilators meet the legal demands. But in some clinical situations there are considerable deviations of the breathing parameters depending on the brand. In conclusion ventilators of different brands are not interchangeable.

Analysis of Variance↗

Marine radioactivity assessment of Mururoa and Fangataufa atolls.

The International Atomic Energy Agency (IAEA) carried out an international project. 'The Study of the Radiological Situation at the Atolls of Mururoa and Fangataufa' with the aim of assessing the present and future radiological situation at the atolls and making recommendations for either monitoring or remedial actions if they are deemed necessary. The paper concentrates on marine radioactivity aspects and gives an estimation of present radionuclide concentrations in water, sediment and biota of the Mururoa and Fangataufa lagoons and the surrounding ocean. The dominant radionuclide in both lagoons is Pu in sediments (the total inventory is approximately 30 TBq). A decline in radionuclide concentrations has been observed in recent years in lagoon water, with the exception of 3H and 90Sr, for which a contribution from underground sources is to be expected. Radionuclide concentrations in biota from the lagoons and the surrounding ocean are low and consistent with previous measurements. The observed radionuclide concentrations in both lagoons imply that no radiological risk exists for hypothetical inhabitants of Mururoa and Fangataufa Atolls.

Animals↗

Mathematical modelling of ventilation mechanics.

Routine application of 'rule of thumb' parameter sets in clinical practice pushes model visions to the background, including the complete framework of assumptions, simplifications, suppositions and conditions. But: models can be very strong tool, when applied selectively--that means, with a clear idea of destination, definition, parameter selection and verification. This article discusses universal issues of modelling--based on ventilation mechanics models in intensive care medicine.

Airway Resistance↗

[Human respiration models and critical observations on respiratory mechanical parameters].

This paper is meant to summarize and compare certain conceptions of modelling human breathing as published by several authors. By means of respiratory mechanics models various definitions of lung mechanics parameters are stated. In lung function diagnostics and artificial ventilation control the generally used parameters are based on different conceptions of models of respiratory processes. For this reason it is necessary to agree on definitions of comparable parameters and to make clear meaning of terms as a base for giving reproductive measurement instructions and obtaining comparable measuring results.

Airway Resistance↗