Extra- and intracellular hydrogen ion-selective microelectrode based on neutral carriers with extended pH response range in acid media.

A series of new neutral hydrogen ion carriers suitable for application in H+-selective microelectrodes is presented. One carrier (ETH 1907) proves to be superior to tridodecylamine currently very much in use. Microelectrodes based on ETH 1907 in an optimized membrane composition exhibit a linear dynamic response function from pH 2 to 9 extended into the acidic range, a response time less than or equal to 5 s, and a resistance of about 35 G omega for a tip diameter of about 1 micron. This makes the electrode suitable for measurements at normal physiological intracellular pH as well as in acid physiological media. Measurements using this microelectrode in proximal tubule cells of isolated perfused frog kidney are presented.

Animals

Design of ionophores for ion-selective microsensors.

Requirements for a reliable use of liquid membrane microelectrodes are discussed in terms of stability, response time, and lifetime on the basis of membrane technological considerations. The selectivity of H+, Li+, Na+, K+, Mg2+, Ca2+, and Cl- microelectrodes is critically evaluated using the Nikolskii-Eisenman formalism. Recent progress in the design of new ionophores is presented. A novel neutral carrier-based Ca2+-selective microelectrode with a detection limit of about 5 X 10(-10) M Ca2+ at a background of 125 mM K+ has been realized. An neutral carrier-based microelectrode for H+ with extended pH range of the sample solution is now available. Promising developments in the field of Li+-, Mg2+-, and Cl--selective ionophores are discussed.

Animals

Cell contamination due to the use of carrier-based microelectrodes.

When using microelectrodes for intracellular ion activity studies, some uncertainties such as interference from cytosolic components at the microelectrode, cell damage, and cell contamination may arise. A model, which treats kinetic processes of the loss of carriers from the membrane phase of microelectrodes into the cytosol and cell membrane, is used for an estimation of the extent and time course of contamination by impaled ion-selective microelectrodes. An isolated model cell consisting of a plasma membrane surrounding a cytosolic milieu is assumed. The results of its considerations represent a worst case situation, in which significant contamination of the cell membrane of such a small isolated single cell might occur during time periods of electrophysiological experiments. In more complex situations, such as in intact tissues, the equilibrium membrane concentrations may be substantially less.

Animals

Ion-selective membrane electrodes for clinical use.

We review ion-selective solvent polymeric membrane electrodes for clinical use. The particular requirements that the clinical application set on the membrane are discussed in terms of selectivity, stability, lifetime, and response time. The performance of currently available electrodes is reviewed, with consideration of actual problems that arise in clinical practice.

Bicarbonates